Infusion Set Intrafix® Primeline F with Y-site, Latex-Free, 180 cm (150 cm + Y + 30 cm), Luer Lock – B. Braun Ref. 4062181 | Box of 100 units

64,38 €

Infusion set B. Braun Intrafix® Primeline F with Y-site, official reference 4062181, manufactured without latex and with DEHP-free PVC tubing. Gravity administration system of 180 cm (150 cm + Y-site + 30 cm), with drip chamber calibrated to 20 drops = 1 ml ± 0.1 ml, 15 µm particulate filter, air inlet with antibacterial filter, high-precision roller clamp and Luer Lock terminal connection. Sterile, single-use product, indicated for administering saline solutions, electrolytes and parenteral medication in hospitalisation, emergency, ICU and home care. Price per box of 100 units, stock format for hospital replenishment and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4062181

Description

1. Commercial Introduction

The Intrafix® Primeline F with Y-site from B. Braun, official reference 4062181, is the reference gravity infusion set for the administration of saline solutions, electrolytes and parenteral medication in hospitalisation, emergency departments, ICU, operating theatre and home care. Its latex-free Y injection port allows bolus medication administration with a syringe without interrupting the main infusion, and its 180 cm tubing (150 cm + Y-site + 30 cm) provides a comfortable reach between the drip stand and the patient. Manufactured latex-free and with DEHP-free PVC, it protects patients and healthcare staff from latex allergies and plasticisers with endocrine risk. It is supplied in a box of 100 units, the most cost-effective format for hospital stock replenishment, pharmacy and institutional purchasing.

2. Technical explanation of the equipment

This administration system connects the solution bag or bottle to the patient’s vascular access via gravity flow: the flow rate is regulated by the height difference between the container and the puncture site, without the need for pumps or power sources. The transparent spike, conforming to ISO standards, allows insertion into the container and incorporates an air inlet with antibacterial filter and closure system that compensates for the vacuum during infusion. The transparent drip chamber, with a rigid upper flow control part and a flexible lower part, is calibrated to 20 drops = 1 ml ± 0.1 ml (distilled water, according to DIN standards) and houses a 15 µm particle filter that retains particles from the container. The 3 × 4.1 mm tubing, DEHP-free, ensures stable flow, and the high-precision roller clamp facilitates adjustment of the infusion rate with maximum stability throughout the process. The latex-free Y-site allows bolus administration of drugs with a syringe and needle without disconnecting the circuit or interrupting the infusion, and the distal Luer Lock end ensures a threaded, leak-proof connection with no risk of accidental disconnection from catheters, three-way stopcocks and extension lines.

3. Technical Specifications

Reference (official B. Braun code) 4062181
Brand / Family Intrafix® Primeline F (B. Braun)
Product type Gravity infusion set with Y-site (air inlet and filter)
Total tubing length 180 cm (150 cm + Y-site + 30 cm)
Tube diameter 3 mm inner × 4.1 mm outer
Drip chamber Transparent, with flow control; calibrated to 20 drops = 1 ml ± 0.1 ml (DIN standards)
Filter 15 µm particle filter in drip chamber
Air inlet With antibacterial filter and closure system
Injection site Latex-free Y-site (bolus administration without interrupting the infusion)
Flow regulator High-precision roller clamp, with tactile identification of the closed position
Spike Transparent, conforming to ISO standards, with protection against punctures when removing from the bottle
Terminal connection Luer Lock
Material DEHP-free PVC; latex-free Y-site
Latex Latex-free
Administration mode Gravity-fed
Use Single-use (sterile)
Presentation Box of 100 units

4. Equivalences and Cross-References

Verification status of reference 4062181: CONFIRMED. The code appears consistently in the official catalogues of B. Braun (Intrafix® Primeline F with Y-site, 180 cm, latex-free) and in authorised distributors, always as a 180 cm gravity set with 3 × 4.1 mm tubing, chamber at 20 drops = 1 ml, 15 µm filter, antibacterial air inlet and Luer Lock connection. Correspondences within the same family are not interchangeable 1:1 when length, configuration or accessories change; they are offered as comparable by category.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
B. Braun Intrafix® Primeline LL 150 cm (Luer Lock) 4062957E Comparable by category (not interchangeable 1:1) Same family and 15 µm filter; without Y-site and length of 150 cm. Confirmed in official catalogue B. Braun.
B. Braun Intrafix® Primeline LL 230 cm (transparent tube) 4060407 Comparable by category (not interchangeable 1:1) Same family and connector; longer length (230 cm), without Y injection port. Confirmed in official catalogue B. Braun.
B. Braun Intrafix® Primeline UV-Protect 230 cm (opaque tubing) 4060563 Comparable by category (not interchangeable 1:1) Opaque tubing with full UV protection and DEHP-free PVC; without Y-site. Indicated for photosensitive drugs.
B. Braun Intrafix® Safeset I.S. LL 180 cm 4063005 Comparable by category (not interchangeable 1:1) Length 180 cm with integrated low-profile safety system (I.S.) and Luer Lock; without Y-site.
Farmaban Gravity infusion system with Y-site 2600 Comparable by category (not interchangeable 1:1) 185 cm tubing, Y-site, Luer Lock connection, 20 drops/ml chamber and 15 µm filter; latex-free. Verified in distributor catalogue; confirm DEHP-free status in official datasheet before substituting.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tenders or substitution. For any substitution between brands, the following must be checked field by field: tubing length, tube diameter, presence and porosity of the filter, Y injection port, terminal connector, air inlet, materials (DEHP-free, BPA-free and latex-free), sterility and regulatory classification of the actual product.

5. Selection tips and variants of interest

Injection point: the latex-free Y-site of this reference allows bolus medication to be administered without interrupting the infusion. If your protocol does not require a Y-site, consider the Intrafix® Primeline LL 150 cm (Ref. 4062957E) or the 230 cm version (Ref. 4060407), from the same family.
Length: the 180 cm (150 + 30) covers the usual distance between the drip stand and the bed. For taller poles or infusion trolleys, request the 230 cm version (Ref. 4060407).
Photosensitive medication: for drugs that require protection from light, use the opaque UV-Protect tubing line (Ref. 4060563).
Additional filtration: if the protocol requires final filtration of 0.2 µm, consider the Intrapur® Inline set (Ref. 4099842N).
Compatibility: always check the Luer Lock thread (6% taper, ISO 80369-7) with the catheter, three-way stopcock and extension lines used.
Storage: store away from light, moisture and heat; each unit includes batch, sterilisation method and expiry date. Single-use product: dispose of it after each administration in accordance with the centre’s regulations.

Additional information

Manufacturer reference

4062181

Brand

B. Braun

Family

Intrafix® Primeline F

Product type

Gravity infusion set with Y-site (air inlet and filter)

Administration system

Gravity-fed

Total length

180 cm (150 cm + Y-site + 30 cm)

Tube diameter

3 mm inner × 4.1 mm outer

Drip chamber

20 drops = 1 ml ± 0.1 ml (DIN standards)

Filter

15 µm particle filter

Air inlet

With antibacterial filter and closure system

Injection port

Latex-free Y-site

Flow regulator

High-precision roller clamp type

Terminal connection

Luer Lock

Material

DEHP-free PVC; latex-free

Sterility

Sterile product, single-use

Presentation

Box of 100 units

Application

Saline solutions, electrolytes and parenteral medication in hospitalisation, emergency departments, ICU and home care

Latex

Latex-free

Reviews

There are no reviews yet.