Description
1. Commercial Introduction
The Intrafix® Primeline F with Y-site from B. Braun, official reference 4062181, is the reference gravity infusion set for the administration of saline solutions, electrolytes and parenteral medication in hospitalisation, emergency departments, ICU, operating theatre and home care. Its latex-free Y injection port allows bolus medication administration with a syringe without interrupting the main infusion, and its 180 cm tubing (150 cm + Y-site + 30 cm) provides a comfortable reach between the drip stand and the patient. Manufactured latex-free and with DEHP-free PVC, it protects patients and healthcare staff from latex allergies and plasticisers with endocrine risk. It is supplied in a box of 100 units, the most cost-effective format for hospital stock replenishment, pharmacy and institutional purchasing.
2. Technical explanation of the equipment
This administration system connects the solution bag or bottle to the patient’s vascular access via gravity flow: the flow rate is regulated by the height difference between the container and the puncture site, without the need for pumps or power sources. The transparent spike, conforming to ISO standards, allows insertion into the container and incorporates an air inlet with antibacterial filter and closure system that compensates for the vacuum during infusion. The transparent drip chamber, with a rigid upper flow control part and a flexible lower part, is calibrated to 20 drops = 1 ml ± 0.1 ml (distilled water, according to DIN standards) and houses a 15 µm particle filter that retains particles from the container. The 3 × 4.1 mm tubing, DEHP-free, ensures stable flow, and the high-precision roller clamp facilitates adjustment of the infusion rate with maximum stability throughout the process. The latex-free Y-site allows bolus administration of drugs with a syringe and needle without disconnecting the circuit or interrupting the infusion, and the distal Luer Lock end ensures a threaded, leak-proof connection with no risk of accidental disconnection from catheters, three-way stopcocks and extension lines.
3. Technical Specifications
| Reference (official B. Braun code) | 4062181 |
| Brand / Family | Intrafix® Primeline F (B. Braun) |
| Product type | Gravity infusion set with Y-site (air inlet and filter) |
| Total tubing length | 180 cm (150 cm + Y-site + 30 cm) |
| Tube diameter | 3 mm inner × 4.1 mm outer |
| Drip chamber | Transparent, with flow control; calibrated to 20 drops = 1 ml ± 0.1 ml (DIN standards) |
| Filter | 15 µm particle filter in drip chamber |
| Air inlet | With antibacterial filter and closure system |
| Injection site | Latex-free Y-site (bolus administration without interrupting the infusion) |
| Flow regulator | High-precision roller clamp, with tactile identification of the closed position |
| Spike | Transparent, conforming to ISO standards, with protection against punctures when removing from the bottle |
| Terminal connection | Luer Lock |
| Material | DEHP-free PVC; latex-free Y-site |
| Latex | Latex-free |
| Administration mode | Gravity-fed |
| Use | Single-use (sterile) |
| Presentation | Box of 100 units |
4. Equivalences and Cross-References
Verification status of reference 4062181: CONFIRMED. The code appears consistently in the official catalogues of B. Braun (Intrafix® Primeline F with Y-site, 180 cm, latex-free) and in authorised distributors, always as a 180 cm gravity set with 3 × 4.1 mm tubing, chamber at 20 drops = 1 ml, 15 µm filter, antibacterial air inlet and Luer Lock connection. Correspondences within the same family are not interchangeable 1:1 when length, configuration or accessories change; they are offered as comparable by category.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Intrafix® Primeline LL 150 cm (Luer Lock) | 4062957E | Comparable by category (not interchangeable 1:1) | Same family and 15 µm filter; without Y-site and length of 150 cm. Confirmed in official catalogue B. Braun. |
| B. Braun | Intrafix® Primeline LL 230 cm (transparent tube) | 4060407 | Comparable by category (not interchangeable 1:1) | Same family and connector; longer length (230 cm), without Y injection port. Confirmed in official catalogue B. Braun. |
| B. Braun | Intrafix® Primeline UV-Protect 230 cm (opaque tubing) | 4060563 | Comparable by category (not interchangeable 1:1) | Opaque tubing with full UV protection and DEHP-free PVC; without Y-site. Indicated for photosensitive drugs. |
| B. Braun | Intrafix® Safeset I.S. LL 180 cm | 4063005 | Comparable by category (not interchangeable 1:1) | Length 180 cm with integrated low-profile safety system (I.S.) and Luer Lock; without Y-site. |
| Farmaban | Gravity infusion system with Y-site | 2600 | Comparable by category (not interchangeable 1:1) | 185 cm tubing, Y-site, Luer Lock connection, 20 drops/ml chamber and 15 µm filter; latex-free. Verified in distributor catalogue; confirm DEHP-free status in official datasheet before substituting. |
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tenders or substitution. For any substitution between brands, the following must be checked field by field: tubing length, tube diameter, presence and porosity of the filter, Y injection port, terminal connector, air inlet, materials (DEHP-free, BPA-free and latex-free), sterility and regulatory classification of the actual product.
5. Selection tips and variants of interest
Injection point: the latex-free Y-site of this reference allows bolus medication to be administered without interrupting the infusion. If your protocol does not require a Y-site, consider the Intrafix® Primeline LL 150 cm (Ref. 4062957E) or the 230 cm version (Ref. 4060407), from the same family.
Length: the 180 cm (150 + 30) covers the usual distance between the drip stand and the bed. For taller poles or infusion trolleys, request the 230 cm version (Ref. 4060407).
Photosensitive medication: for drugs that require protection from light, use the opaque UV-Protect tubing line (Ref. 4060563).
Additional filtration: if the protocol requires final filtration of 0.2 µm, consider the Intrapur® Inline set (Ref. 4099842N).
Compatibility: always check the Luer Lock thread (6% taper, ISO 80369-7) with the catheter, three-way stopcock and extension lines used.
Storage: store away from light, moisture and heat; each unit includes batch, sterilisation method and expiry date. Single-use product: dispose of it after each administration in accordance with the centre’s regulations.





Reviews