Description
1. Introduction
The Introcan Safety-W winged safety catheter from B. Braun, G20 gauge and 1.1 × 32 mm size (ref. 4253566-01), is the reference solution for achieving safe, rapid and reliable peripheral venous access in adult patients with standard intravenous therapies. It combines the recognised passive safety technology of the Introcan system with a polyurethane (PUR) catheter body that reduces irritation of the venous wall and allows comfortable and stable cannulation. A single-use, sterile product designed for hospitalisation, emergency departments, operating theatres and any unit where clinical safety and protection of healthcare staff are a priority.
2. Technical explanation of the procedure
The Introcan Safety-W catheter is introduced into the vein using a controlled single-step puncture technique. Its hub with fixation wings allows a firm and ergonomic grip, facilitating stabilisation of the assembly during cannulation and subsequent fixation with a dressing. Once the needle is withdrawn from the catheter, the passive auto-activation safety mechanism (protection clip) automatically encapsulates the needle tip within the device, without requiring any additional action from the professional: this eliminates exposure to the contaminated needle and minimises the risk of accidental needlestick injury, in line with European regulations on the prevention of biological accidents.
The polyurethane (PUR) material offers greater intravascular flexibility, lower thrombogenicity and better tolerance in prolonged access compared with other materials. This G20 gauge, with a length of 32 mm, is ideal for routine intravenous therapies in adults, and its female Luer-Lock connection guarantees compatibility with standard infusion lines.
3. Technical Specifications
| Characteristic | Specification |
| Manufacturer / Series | B. Braun – Introcan Safety-W (Introcan W Safety) |
| Manufacturer reference | 4253566-01 |
| Product type | Peripheral intravenous safety catheter with wings (winged) |
| Gauge | 20G (external Ø 1.1 mm) |
| Size (Ø × length) | 1.1 × 32 mm |
| Catheter material | Polyurethane (PUR) |
| Colour code | Pink (ISO 10555-5) |
| Safety system | Passive, auto-activation (needle protection clip) |
| Connection | Female Luer-Lock |
| Design | With fixation wings for stability and fixation |
| Presentation | Box of 50 units, sterile, single-use |
| Main indication | Intravenous injection, infusion and transfusion in adult patients |
Introcan Safety-W family with wings (B. Braun) by gauge
| Reference | Gauge | Size (Ø × length) |
| 4251614-01 | 24G | 0.7 × 14 mm |
| 4253523-01 | 24G | 0.7 × 19 mm |
| 4253540-01 | 22G | 0.9 × 25 mm |
| 4253566-01 | 20G | 1.1 × 32 mm |
| 4253604-01 | 18G | 1.3 × 32 mm |
| 4253590-01 | 18G | 1.3 × 45 mm |
| 4253612-01 | 16G | 1.7 × 50 mm |
| 4253639-01 | 14G | 2.2 × 50 mm |
4. Equivalences and Cross-References
The reference 4253566-01 has been verified as Introcan Safety-W PUR, 20G, 1.1 × 32 mm, pink in colour, in the catalogue of the Introcan family itself from B. Braun and in authorised distribution sources, so the code is considered valid. Within the same family and manufacturer, the variants in the following table share the system and material but differ in gauge or length.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| B. Braun | Introcan Safety-W with wings | 4253604-01 | Comparable by category (not interchangeable 1:1) | G18 gauge (1.3 × 32 mm); same length but higher flow rate for transfusions and high-flow infusions. |
| B. Braun | Introcan Safety-W PUR with wings | 4253540-01 | Comparable by category (not interchangeable 1:1) | G22 gauge (0.9 × 25 mm); smaller gauge, for veins of smaller diameter or lower-flow therapies. |
| B. Braun | Introcan Safety-W PUR with wings | 4253523-01 | Comparable by category (not interchangeable 1:1) | G24 gauge (0.7 × 19 mm); paediatric profile with fine gauge. |
| B. Braun | Introcan Safety-W PUR with wings | 4251614-01 | Comparable by category (not interchangeable 1:1) | G24 gauge (0.7 × 14 mm); shorter version for neonatology and very fine veins. |
| B. Braun | Introcan Safety-W with wings | 4253590-01 | Comparable by category (not interchangeable 1:1) | Gauge G18 (1.3 × 45 mm); long version for deep veins. |
| B. Braun | Introcan Safety-W with wings | 4253612-01 | Comparable by category (not interchangeable 1:1) | Gauge G16 (1.7 × 50 mm); high flow for critically ill adult patients. |
| B. Braun | Introcan Safety-W with wings | 4253639-01 | Comparable by category (not interchangeable 1:1) | Gauge G14 (2.2 × 50 mm); maximum flow rate of the family. |
There is no equivalence table validated by the manufacturer between this catheter and the safety systems of other brands; consult the technical department before use in tenders. As homologous families of winged safety catheters comparable by category (not interchangeable 1:1), the following stand out: BD Insyte Autoguard Winged and Venflon Pro Safety (BD, shield with needle withdrawal by button, Vialon material), SafeTouch (Nipro), Leaderflex (Vygon) and Surflo W (Terumo). In all cases, gauge, length, material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; their specific codes for G20 could not be verified in public sources and must be confirmed with the manufacturer before use.
5. Selection tips and variants of interest
Always select the gauge and length appropriate to the venous territory and the type of therapy: this G20 of 32 mm (ref. 4253566-01) is a very balanced option for standard intravenous therapies in adults, with good flow rate and manageable gauge. For finer veins or the paediatric population, consider the G24 of 14 mm (4251614-01) or 19 mm (4253523-01) and the G22 of 25 mm (4253540-01); for rapid transfusions and surgery, move up to G18 (4253604-01 or 4253590-01), G16 (4253612-01) or G14 (4253639-01). Complete the stock with the obturation stylets from the Introcan family (ref. 4214110 for 20G) to keep the line cannulated between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, respect the aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.





Reviews