We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Obturator Stylet 18G (1.3 mm) x 33 mm for Vasofix Safety Braun Catheter | Ref. 4219139 | Box of 50 units

29,42 €

The Obturator stylet 18G x 33 mm Vasofix Safety from B. Braun (Ref. 4219139) is the official replacement accessory for the Vasofix, Vasocan and Braunüle range: it seals the catheter lumen during infusion pauses, prevents blood reflux, prevents thrombi and obstructions, and maintains line asepsis without heparinising or removing the catheter. Gauge 18G (1.3 mm), 33 mm length, green colour code, surgical stainless steel, sterile and single-use. Supplied in a box of 50 units. Essential in hospitalisation, emergency, surgery and oncology.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4219139

Description

1. Introduction

The B. Braun Vasofix Safety 18G x 33 mm obturator stylet (Ref. 4219139) is the reference accessory for keeping a peripheral intravenous catheter cannulated during infusion or transfusion pauses. An essential piece in hospitalisation, emergency, surgery, oncology and any unit where the patient keeps the line for several hours or days: it prevents the catheter from occluding or becoming contaminated between administrations, reduces new punctures and protects both the patient and healthcare staff. Verified in the manufacturer’s official catalogue under the designation MANDRIN/STYLET VASOFIX 18G X 33 MM (CI50 presentation), it is supplied in individual sterile packaging and a box of 50 single-use units.

2. Technical explanation of the equipment and procedure

In peripheral intravenous cannulation, the mandrel or stylet has a dual function. During puncture, the internal needle guides the introduction of the catheter through the skin and the vein wall; once venous return is confirmed, it is removed and the polyurethane catheter remains implanted. When infusion is interrupted, the mandrel acts as an obturator: when inserted into the lumen, it seals it hermetically, prevents blood reflux into the lumen, prevents the formation of thrombi and obstructions and maintains the asepsis of the circuit without the need for heparinisation or removal of the line. To resume therapy, the professional removes the mandrel and reconnects the infusion line, avoiding additional punctures and reducing the risk of accidental needle exposure for healthcare staff.

Reference 4219139 corresponds to gauge 18G (1.3 mm outer diameter) with a length of 33 mm, designed for the 33 mm catheters of the Vasofix Safety family. Its green colour code matches that of the catheter it accompanies (in accordance with the ISO 10555-5 coding), which facilitates rapid identification on the dressing trolley and avoids gauge errors.

3. Technical Specifications

Parameter Specification
Manufacturer / Series B. Braun – Vasofix Safety (obturator stylet)
Manufacturer reference 4219139
Product type Obturator stylet for peripheral catheter
Gauge 18G (1.3 mm outer diameter) – green colour code (ISO 10555-5)
Length 33 mm
Clinical function Temporary interruption of infusion/transfusion; prevents thrombi, obstructions and reflux
Compatibility Vasofix Safety, Vasocan and Braunüle catheters
Material High-quality surgical stainless steel
Sterility Yes, sterile (ethylene oxide)
Use Single-use / disposable
Presentation Individual sterile packaging · Box of 50 units

Vasofix Safety mandrel family (B. Braun):

Reference Gauge Length
4219201 14G (2.2 mm) 50 mm
4219171 16G (1.7 mm) 50 mm
4219139 18G (1.3 mm) 33 mm
4219120 18G (1.3 mm) 45 mm
4219104 20G (1.1 mm) 33 mm
4215095 22G (0.9 mm) 25 mm

4. Equivalences and Cross-References

Reference 4219139 has been verified in the manufacturer’s official catalogue B. Braun (Vasofix stylet series, CI50 presentation) and in independent authorised distribution sources, so the code is considered valid.

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun Vasofix Safety (obturator stylet) 4219120 Comparable by category (not interchangeable 1:1) Same system and gauge 18G (1.3 mm) but length 45 mm; indicated for Vasofix catheters of 45 mm.
B. Braun Introcan (obturator stylet) 4214323 Comparable by category (not interchangeable 1:1) Gauge 18G and length 1 1/4″ (31.75 mm) very close to 33 mm, but Introcan catheter system with a different cone geometry to Vasofix; verify compatibility before substituting.
B. Braun Vasofix Safety (obturator stylet) 4219104 Comparable by category (not interchangeable 1:1) Same length 33 mm but gauge 20G (1.1 mm); for smaller gauge catheters.
B. Braun Introcan (obturator stylet) 4214137 Comparable by category (not interchangeable 1:1) Gauge 18G in length 1 3/4″ (44.45 mm); Introcan system with a different cone to Vasofix.

There is no manufacturer-validated equivalence table that allows this mandrel to be substituted 1:1 by a stylet from another brand with documentary guarantee; consult the technical department before use in tenders. The equivalent families of safety catheters from other manufacturers (BD’s Venflon Pro Safety and Insyte Autoguard, Nipro’s SafeTouch, Vygon’s Leaderflex or ICU Medical’s Intuitiv) integrate the obturation into the catheter itself (blood control septum or internal needle), so they are not interchangeable 1:1 with this independent mandrel.

5. Selection tips and variants of interest

Always select the mandrel of the same gauge as the cannulated catheter and with a length matching that of the catheter: for an 18G 33 mm catheter use this reference 4219139; if your protocol uses 18G 45 mm catheters, have the 4219120 variant available. For the other gauges of the Vasofix Safety family, B. Braun offers the following range:

Reference Description
4219201 Vasofix Safety mandrel/stylet 14G x 50 mm (C/50)
4219171 Vasofix Safety mandrel/stylet 16G x 50 mm (C/50)
4219139 Vasofix Safety mandrel/stylet 18G x 33 mm (C/50) – product analysed
4219120 Vasofix Safety mandrel/stylet 18G x 45 mm (C/50)
4219104 Vasofix Safety mandrel/stylet 20G x 33 mm (C/50)
4215095 Vasofix Safety mandrel/stylet 22G x 25 mm (C/50)

For gauge 18G, combine this mandrel with the Vasofix Safety G18 1.3 x 33 mm catheter from the same family, with which it forms a perfectly integrated set. In Cahnos you will also find the corresponding Vasofix Safety catheters, the Introcan Safety line mandrels and the rest of the peripheral venous puncture material. Check the integrity of the packaging and the sterility expiry date before each use, follow aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.

Additional information

Gauge

18G (1.3 mm outer diameter)

Colour code

green (ISO 10555-5)

Material

High-quality surgical stainless steel

Compatibility

Vasofix Safety, Vasocan and Braunüle catheters

Sterilisation

Yes, sterile (ethylene oxide)

Use

Single-use / disposable

Presentation

Individual sterile packaging · Box of 50 units

Manufacturer reference

4219139

Manufacturer

B. Braun

Longitud

3.3 cm

Reviews

There are no reviews yet.

Be the first to review “Obturator Stylet 18G (1.3 mm) x 33 mm for Vasofix Safety Braun Catheter | Ref. 4219139 | Box of 50 units”

Your email address will not be published. Required fields are marked *