We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Introcan Safety Braun Intravenous Safety Catheter 18G (1.3 × 32 mm) PUR Wingless | Ref. 4251687-01 | Box of 50 units

104,55 €

Introcan Safety safety catheter from B. Braun, 18G (1.3 × 32 mm) in polyurethane (PUR) and wingless presentation, reference 4251687-01. Its passive safety mechanism automatically shields the needle tip upon withdrawal, without any manual action by the professional, drastically reducing the risk of accidental needlestick injury and exposure to bloodborne pathogens, in line with Directive 2010/32/EU. The 18G gauge provides a high flow rate, suitable for rapid transfusions, high-volume infusions and high-viscosity fluids, while maintaining the flexibility and intravascular tolerance offered by polyurethane. Female Luer-Lock connection, sterile and single-use, in a box of 50 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4251687-01
Tags

Description

1. Introduction

The Catheter SEG G18 1.3 × 32 mm-PUR Introcan Safety Braun (Ref. 4251687-01) is a peripheral intravenous safety catheter designed to provide reliable vascular access, comfortable for the patient and especially safe for the healthcare professional. It combines the recognised passive safety technology of the Introcan system with a polyurethane (PUR) cannula, the reference material in hospitalisation for its balance between intravascular flexibility, less irritation of the venous wall and stability in prolonged access.

Its G18 gauge and 32 mm length make it the usual choice for therapies requiring a high flow rate: transfusions of blood products, rapid volume expansion, surgery and administration of higher-viscosity drugs in adult patients. It is supplied sterile, single-use, in a box of 50 units.

2. Technical explanation of the system and procedure

The Introcan Safety system integrates a polyurethane (PUR) cannula mounted on a bevelled guide needle (type over-the-needle). During cannulation, the needle pierces the skin and the venous wall; once blood return is confirmed through the flashback chamber, the cannula is advanced to its intravascular position and the guide needle is withdrawn: the passive safety mechanism automatically encapsulates the bevel inside a protective chamber and locks it irreversibly, without requiring any additional action from the professional.

This eliminates re-exposure to the contaminated needle and minimises the risk of biological accident from needlestick, in line with European regulations on prevention of risks from sharp objects (Directive 2010/32/EU). The polyurethane softens at body temperature, favours the permanence of the access and reduces the incidence of mechanical phlebitis, maintaining a stable lumen for the passage of fluids. The female Luer-Lock connection is compatible with standard infusion lines, three-way stopcocks and extension sets on the market.

3. Technical Specifications

Parameter Value
Manufacturer reference 4251687-01 (Introcan Safety PUR 18G, 1.3 × 32 mm)
Manufacturer / Family B. Braun – Introcan Safety (without wings)
Product type Peripheral intravenous safety catheter (over-the-needle)
Gauge 18G (outer diameter 1.3 mm)
Size (Ø × length) 1.3 × 32 mm
Cannula material Polyurethane (PUR)
Colour code Green (ISO 10555-5)
Safety system Passive, with shielding and irreversible needle lock
Connection Female Luer-Lock
Design Wingless, without injection port
Use Intravenous injection, infusion and transfusion
Sterilisation / use Sterile, single-use
Presentation Box of 50 units

Gauge range of the Introcan Safety family (without wings) as an ordering reference:

Reference Gauge Size (Ø × length)
4251607-01 24G 0.7 × 14 mm
4251601-01 24G 0.7 × 19 mm
4251628-01 22G 0.9 × 25 mm
4251644-01 20G 1.1 × 32 mm
4251687-01 18G 1.3 × 32 mm
4251679-01 18G 1.3 × 45 mm
4253612-01 16G 1.7 × 50 mm
4253639-01 14G 2.2 × 50 mm

4. Equivalences and Cross-References

The reference 4251687-01 has been verified in the authorised distribution catalogue and public sources such as INTROCAN SAFETY PUR 18G CORTO 32MM from B. Braun Melsungen AG, presentation without wings and box of 50 units, so the code is considered valid. The green colour code corresponds to the 18G gauge in accordance with standard ISO 10555-5. The confirmed cross-references within the same family and other comparable lines are detailed below; the cross-reference is offered as a technical comparison and should not be treated as 1:1 interchangeability without assessment of the procedure.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
B. Braun Introcan Safety-W with wings, G18 PUR 4253604-01 Comparable by category (not interchangeable 1:1) Same G18 gauge (1.3 mm), same 32 mm length and PUR material; incorporates fixation wings for reinforced fixation.
B. Braun Introcan Safety without wings, G18 PUR 45 mm 4251679-01 Comparable by category (not interchangeable 1:1) Same family, same configuration without wings and PUR material; longer length (45 mm) for deep veins or thick subcutaneous tissue.
BD Insyte Autoguard Shielded IV Catheter, 18G × 1.16″ straight 381444 Comparable by category (not interchangeable 1:1) Same gauge with approximate length of 30 mm (1.16″); Vialon biomaterial (not PUR) and active safety with needle retraction by button; verified in BD catalogue and GUDID.
BD Insyte Autoguard BC Shielded IV Catheter, 18G × 1.16″ straight 382544 Comparable by category (not interchangeable 1:1) Same base as the 381444 with Blood Control technology; Vialon and safety activation by button; the safety mechanism and material differ from PUR.

There is no equivalence table validated by the manufacturer between this catheter and the safety systems of other brands; consult the technical department before use in tenders. As homologous families of safety catheters with passive or active protection comparable by category (not 1:1 interchangeable), Nipro SafeTouch (whose 18G variants are offered in lengths of 32 and 50 mm), Terumo Surflo and Vygon Leaderflex stand out, as well as BD winged models (e.g. 381547). In all cases, the gauge, useful length, cannula material, flow rate, type of safety activation and the presence of wings or injection port must be verified in the manufacturer’s technical data sheet before any substitution; the specific codes of those brands for this size must be confirmed with the manufacturer before use.

5. Selection tips and variants of interest

Always select the smallest gauge that allows the prescribed therapy: this G18 of 32 mm (Ref. 4251687-01) is the balanced option for adult patients requiring high flow rate in a contained route. If the protocol requires greater intravascular length for deep veins, the G18 version of 45 mm without wings (Ref. 4251679-01) or with wings (Ref. 4253590-01) are natural alternatives; if reinforced fixation is preferred with the same size, the Introcan Safety-W G18 of 32 mm with wings (Ref. 4253604-01). For standard adult therapies, consider G20 (4251644-01) or G22 (4251628-01); for maximum flow rate, G16 (4253612-01) or G14 (4253639-01).

Complete the stock with the obturators of the Introcan family to keep the cannulated route between administrations without risk of occlusion. Always verify the integrity of the packaging and the sterility expiry date before each use, respect aseptic technique and dispose of it after a single use in a sharps container in accordance with the manufacturer’s instructions; the product must not be re-sterilised.

Additional information

Brand

B. Braun (Introcan Safety)

Manufacturer reference

4251687-01

Product type

Peripheral intravenous safety catheter (over-the-needle)

Gauge

18G

Material

Polyurethane (PUR)

Colour code

Green (ISO 10555-5)

Safety system

Passive, automatic and irreversible needle shielding

Connection

Female Luer-Lock

Design

Wingless, without injection port

Use

Intravenous injection, infusion and transfusion

Sterilisation

Sterile, single-use

Presentation

Box of 50 units

Diametro mm

13 mm

Longitud

3.2 cm

Reviews

There are no reviews yet.

Be the first to review “Introcan Safety Braun Intravenous Safety Catheter 18G (1.3 × 32 mm) PUR Wingless | Ref. 4251687-01 | Box of 50 units”

Your email address will not be published. Required fields are marked *