We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Intravenous Safety Catheter with Wings Introcan W Safety Braun G14 2.2 × 50 mm (PUR, Orange) | Ref. 4253639-01 | Box of 50 units

104,55 €

Winged safety catheter Introcan W Safety (Braun) in gauge G14 of 2.2 × 50 mm, the one with the highest flow rate in the family. Its passive auto-activation safety system automatically encapsulates the needle tip upon withdrawal, eliminating the risk of accidental needlestick injury without any additional action from the professional. The polyurethane (PUR) body reduces irritation of the venous wall and improves tolerance during prolonged access, while the fixation wings provide stability and control during cannulation and fixation with a dressing. Female Luer-Lock connection and orange colour code (ISO 10555-5). Indicated for rapid transfusions, high-volume infusions, contrast administration and critically ill patients. Sterile, single-use, in a box of 50 units. Manufacturer’s reference: 4253639-01.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4253639-01

Description

1. Introduction

The Introcan W Safety Winged Safety Catheter from B. Braun in gauge G14 and size 2.2 × 50 mm (ref. 4253639-01) is the highest flow rate solution in the family of peripheral intravenous safety catheters with wings. It is designed to provide safe, rapid, high-flow venous access in critically ill adult patients: emergency departments, operating theatre, resuscitation, ICU, transfusion units and interventional radiology services. It combines the recognised passive safety technology of the Introcan system with a polyurethane (PUR) catheter body that reduces venous wall irritation and allows comfortable and stable cannulation even during prolonged access. It is a single-use, sterile product, designed for the protection of the patient and healthcare personnel.

2. Technical explanation of the equipment and procedure

The Introcan W Safety catheter is inserted into the vein using a controlled single-step puncture technique. Its hub with fixation wings allows a firm and ergonomic grip, facilitating stabilisation of the assembly during cannulation and subsequent fixation with a dressing.

Once the needle is withdrawn from the catheter, the self-activating passive safety mechanism (protection clip) automatically encapsulates the needle tip within the device, requiring no additional action from the clinician: this eliminates exposure to the contaminated needle and minimises the risk of accidental needlestick injury, in line with the European directive on the prevention of biological accidents (Directive 2010/32/EU).

The polyurethane (PUR) material offers greater intravascular flexibility, lower thrombogenicity and better tolerance in prolonged access. The G14 gauge (outer diameter 2.2 mm) with a length of 50 mm provides the highest flow rate in the family, ideal for rapid transfusions, large-volume infusions, high-viscosity fluids and contrast administration, with a female Luer-Lock connection compatible with standard infusion lines on the market.

3. Technical Specifications

Manufacturer / Series B. Braun – Introcan Safety-W (Introcan W Safety)
Manufacturer reference 4253639-01 (INTROCAN SAFETY-W PUR 14G, 2.2X50MM-EU)
Product type Peripheral intravenous safety catheter with wings (winged)
Gauge 14G (outer Ø 2.2 mm)
Size (Ø × length) 2.2 × 50 mm
Catheter material Polyurethane (PUR)
Colour code Orange (ISO 10555-5)
Safety system Passive, auto-activation (needle protection clip)
Connection Female Luer-Lock
Design With fixation wings for stability and fixation
Sterilisation / use Sterile, single-use
Presentation Box of 50 units
Main indication Rapid transfusion, large-volume infusion, viscous fluids and contrast in critically ill adult patients

Gauge range of the Introcan Safety-W family with wings (B. Braun):

Reference Gauge Size (Ø × length)
4251614-01 24G 0.7 × 14 mm
4253523-01 24G 0.7 × 19 mm
4253540-01 22G 0.9 × 25 mm
4253566-01 20G 1.1 × 32 mm
4253604-01 18G 1.3 × 32 mm
4253590-01 18G 1.3 × 45 mm
4253612-01 16G 1.7 × 50 mm
4253639-01 14G 2.2 × 50 mm

4. Equivalences and Cross-References

The reference 4253639-01 is verified in the catalogue of the Introcan family from B. Braun as Introcan Safety-W PUR 14G, 2.2 × 50 mm, EU version with wings (CI50 presentation), therefore the code is considered valid. The orange colour code corresponds to gauge 14G according to standard ISO 10555-5 (colour coding for intravascular devices).

There is no equivalence table validated by the manufacturer between this catheter and safety systems from other brands; consult the technical department before using in tenders. Within the same manufacturer, the closest alternative in gauge and length is:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun Vasofix Safety G14 PUR 4269225S-01 Comparable by category (not interchangeable 1:1) Same manufacturer, gauge G14 (2.2 mm) and length 50 mm in PUR; without fixation wings and with a retraction/sheathing safety mechanism different from the passive clip of the Introcan W. Verified in the manufacturer’s catalogue.

Comparable homologous families of winged safety catheters by category (not interchangeable 1:1) include: BD Insyte Autoguard Winged and BD Venflon Pro Safety (BD, shield with button-activated needle retraction, Vialon material), Surflo W / Surflash W (Terumo), SafeTouch (Nipro), Leaderflex (Vygon) and passive activation PUR safety catheters of European distribution (Know Medical type). In all cases, the gauge, usable length, catheter material, flow rate and safety mechanism must be verified in the manufacturer’s technical data sheet before any substitution; their specific codes for G14 with wings could not be cross-checked in public sources and must be confirmed with the manufacturer before use.

5. Selection tips and variants of interest

Always select the gauge and length according to the venous territory and type of therapy: this G14 of 50 mm (ref. 4253639-01) is the highest flow rate option in the family, reserved for critically ill adult patients, rapid transfusions, major surgery, large-volume infusion and contrast administration. If a very high flow rate is needed with a slightly more manageable gauge, the G16 of 50 mm (ref. 4253612-01) is the natural alternative; for standard adult therapies, consider G18 (4253604-01 or 4253590-01) or G20 (4253566-01), and for fine-gauge veins or paediatric population, G22 (4253540-01) or G24 (4251614-01 / 4253523-01).

Complete the stock with the 14G 2″ obturator stylet (ref. 4214218) from the Introcan family to keep the line cannulated between administrations without risk of occlusion. Always check the integrity of the packaging and the sterility expiry date before each use, follow aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.

Additional information

Manufacturer

B. Braun

Manufacturer reference

4253639-01

Family

Introcan Safety-W (Introcan W Safety)

Product type

Peripheral intravenous safety catheter with wings (winged)

Gauge

14G

Size

2.2 × 50 mm (outer diameter × length)

Material

Polyurethane (PUR)

Colour code

Orange (ISO 10555-5)

Safety system

Passive, auto-activation (needle protection clip)

Connection

Female Luer-Lock

Design

With fixation wings

Sterilisation

Sterile, single-use

Presentation

Box of 50 units

Indications

Rapid transfusion, large-volume infusion, viscous fluids and contrast in critical patients

Compatible stylet

4214218 (14G, 2")

Reviews

There are no reviews yet.

Be the first to review “Intravenous Safety Catheter with Wings Introcan W Safety Braun G14 2.2 × 50 mm (PUR, Orange) | Ref. 4253639-01 | Box of 50 units”

Your email address will not be published. Required fields are marked *