Semi-automatic 14G biopsy needle (SPRING-CUT, Sterylab) – Gauge 14, Tru-Cut guillotine system, lengths 11, 15, 20 and 25 cm

Price on request

Semi-automatic 14G biopsy needle from the SPRING-CUT range by Sterylab (Italy). Tru-Cut guillotine system for soft tissues, operable with one hand and ideal for ultrasound-guided procedures: stylet button locked during penetration, presettable biopsy throw (5/10/20 mm), safety against accidental firing, centimetre-graduated cannula and echoreflective steel needle with echogenic marker. Available in lengths of 11, 15, 20 and 25 cm. Sterile, single-use, in individual blister (box of 20 units). Ref. SPRINGCUT14.

International shipping. Import duties and taxes are payable by the recipient.

Reference
SPRINGCUT14

Description

Semi-automatic 14G biopsy needle – Precision and control in every sample collection

The semi-automatic 14G biopsy needle from the SPRING-CUT range represents the latest generation of guillotine-type biopsy devices for soft tissues. Designed by Sterylab S.r.l. (Rho, Milan, Italy), it combines a robust mechanism with ergonomic handling that allows the professional to work with one hand, facilitating the manipulation of the ultrasound probe during the procedure. Available in lengths of 11, 15, 20 and 25 cm, it adapts to different depths and clinical specialties, ensuring reliable, high-quality diagnostic results.

Technical explanation of the device

This semi-automatic soft-tissue biopsy instrument works via a spring-loaded guillotine system: the operator cocks the needle, positions it under image guidance and triggers the firing so that the cutting cannula advances and captures the sample in the extraction notch. Its exclusive design keeps the stylet advance button locked during penetration, which simplifies the manoeuvre, increases safety and improves sensitivity when passing through tissue. The biopsy throw is presettable (5, 10 or 20 mm) to suit the size of the lesion, and it incorporates a retention safety to prevent accidental firing, a centimetre-graduated cannula to control depth and an echoreflective steel needle with an echogenic marker that allows the entire device to be visualised on the ultrasound monitor.

Technical specifications

Specification Detail
Gauge 14G (2.00 mm)
Available lengths 11, 15, 20 and 25 cm
Mechanism type Semi-automatic guillotine type (Tru-Cut)
Biopsy throw Presettable: 5 / 10 / 20 mm
Use Single-handed, ideal with ultrasound guidance
Safety Locking safety (cran) against accidental firing
Display Echoreflective steel with echogenic marker at the tip
Cannula Graduated in centimetres, with depth markings
Removable stylet and cannula Yes: sample control and multiple biopsies (e.g. prostate mapping)
Coding Colour code for gauge identification
Sterility Sterile, single-use (individual blister)
Presentation Box of 20 units
Manufacturer Sterylab S.r.l. (Rho, Milan, Italy)
Reference SPRINGCUT14

Available variants by length (14G gauge):

Reference Gauge Length
SPG1411 14G 11 cm
SPG1415 14G 15 cm
SPG1420 14G 20 cm
SPG1425 14G 25 cm
SPG1447 14G 47 cm

Equivalences and cross-references

The SPRING-CUT 14G device belongs to the family of semi-automatic Tru-Cut type needles for soft tissues. It is comparable to reference core biopsy systems such as the Original TEMNO and Achieve (CareFusion/BD), as well as the Magnum and TruGuide automatic biopsy gun needles from Bard/BD. Compared to automatic double-firing systems, its semi-automatic single-handed firing mechanism offers finer control in image-guided procedures. Within the Sterylab catalogue, this needle is complemented by the FAST-CUT range (needles for the MAGNUM automatic pistol) and has specific versions: SPRING-CUT DC (removable cannula for multiple accesses), SPRING-CUT SET-TAC (set with guide needle for coaxial procedures under CT) and the PLUS+ versions (ECHONOX alloy needle for maximum ultrasound visualisation) and PLUS++ (TOP-CORE geometry that captures up to 50% more abundant samples, only 14-18G gauges). Equivalent international commercial code: HM-390241-14-11/15/20/25.

Selection tips and variants of interest

The 14G gauge provides larger-diameter samples, being especially indicated for biopsies of the breast, liver, kidney, prostate and deep lesions where abundant, high-quality tissue is required for histological study. Select the length according to the depth of the lesion: 11 cm for superficial lesions, 15-20 cm for medium depth and 25 cm (or 47 cm) for deep tissues or special accesses. For procedures with multiple sample collection through a single access, consider the version with removable cannula (SPRING-CUT DC); for CT guidance, the coaxial set (SPRING-CUT SET-TAC). If you need superior ultrasound visualisation or even more abundant samples, consult the PLUS+ (ECHONOX) and PLUS++ (TOP-CORE) versions. Contact our technical-commercial team to select the most suitable reference for your specialty and consumption volume.

Additional information

Gauge

14G (2.00 mm)

External diameter mm

2.00

Available lengths

11, 15, 20 and 25 cm (47 cm variant)

Mechanism type

Semi-automatic guillotine type (Tru-Cut)

Biopsy throw

Presettable 5 / 10 / 20 mm

Use

Single-handed, ideal with ultrasound guidance

Safety

Locking safety (cran) against accidental firing

Display

Echoreflective steel with echogenic marker

Cannula

Graduated in centimetres with depth markings

Removable stylet and cannula

Yes (multiple biopsies)

Gauge coding

Colour code

Sterilisation

Sterile, single-use (individual blister)

Presentation

Box of 20 units

Manufacturer

Sterylab S.r.l. (Rho, Milan, Italy)

Product class

Medical device class IIa (CE/MDR)