We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

14G Automatic Biopsy Instrument with Guillotine System for Soft Tissue | Lengths 11, 15, 20 and 25 cm (Ref. COLT14)

Price on request

14G automatic biopsy instrument with guillotine system for obtaining high-quality diagnostic tissue samples in soft tissue. Its automatic firing mechanism ensures rapid, clean and controlled cuts that preserve the histological architecture of the sample. Available in lengths of 11, 15, 20 and 25 cm, it adapts to the depth of each lesion and to image-guided techniques (ultrasound, CT or fluoroscopy) in interventional radiology, oncology and diagnostic surgery. Sterile and single-use, manufactured with medical-grade materials that ensure rigidity, hygiene and minimal cross-contamination. Reference COLT14.

International shipping. Import duties and taxes are payable by the recipient.

Reference
COLT14

Description

The 14G automatic biopsy instrument with guillotine system (ref. COLT14) is the ideal solution for professionals who need to obtain large, high-quality diagnostic tissue samples quickly, safely and reproducibly. Designed for percutaneous soft tissue biopsies, it combines a 14G gauge with an automatic firing mechanism that reduces operator fatigue and ensures consistent, clean and controlled cuts. Available in lengths of 11, 15, 20 and 25 cm, it adapts to different access depths and clinical specialties, from interventional radiology to oncology and diagnostic surgery.

Technical explanation of the device and procedure

This puncture biopsy device works by means of an automatic double-advance guillotine-type firing mechanism: when the system is activated, the cutting cannula advances in a synchronised and controlled manner to section the tissue and capture the sample in the notch of the extraction stylet. As it is a spring-loaded advance, the cutting speed is constant and independent of manual movement, which reduces tissue trauma and preserves the histological architecture required for a correct anatomopathological analysis. Its ergonomic and robust design facilitates one-handed handling, providing control, stability and safety in biopsies guided by ultrasound, computed tomography or fluoroscopy in organs such as the liver, kidney, breast, thyroid, prostate and soft tissue masses. The 14G gauge allows larger sample cores to be obtained, especially indicated when abundant material is required for complete anatomopathological studies.

Technical specifications

Parameter Specification
Reference COLT14
Gauge 14G (approx. 2.1 mm diameter)
Cutting system Automatic guillotine for precise and controlled cuts
Available lengths 11 cm, 15 cm, 20 cm and 25 cm
Type of use Disposable, single-use
Sterility Sterile, guarantees maximum hygiene
Material High-strength stainless steel and medical-grade polymer components
Applications Percutaneous soft tissue biopsy in radiology, oncology and surgery

Length options according to access depth:

Length Approximate indication
11 cm Superficial lesions and nearby access routes
15 cm Intermediate approaches and breast or thyroid biopsies
20 cm Deep tissues and hepatic or renal biopsies
25 cm Deep access routes and prostate biopsies

Equivalences and cross-references

This 14G automatic instrument falls within the family of guillotine-type soft tissue biopsy devices. It is comparable to the type B double-fire automatic biopsy systems commonly used in oncological diagnostics and interventional procedures, compatible with automatic-firing biopsy guns from specialised manufacturers. Within the Cahnos range, the same automatic mechanism is available in other gauges: COLT16 (16G), COLT18 (18G) and COLT20 (20G). If manual actuation is preferred, the references BIOCUT14, BIOCUT16, BIOCUT18 and BIOCUT20 are available; and for semiautomatic one-handed control, the reference SPRINGCUT18. For non-magnetic applications safe in magnetic resonance imaging, the BIO-CUT needle (ref. CAHBIOCUT) can be considered.

Selection tips and variants of interest

The 14G gauge offers the largest sample volume in the automatic range, being especially indicated for soft tissue lesions where abundant material of high histological quality is required, such as hepatic, renal, mammary or dense soft tissue masses. Select the length according to the depth of the lesion: 11 cm for superficial lesions, 15-20 cm for medium depth and 25 cm for deep tissues or special accesses. If you prefer less tissue aggressiveness or smaller samples in delicate lesions, consider the 16G (COLT16), 18G (COLT18) or 20G (COLT20) gauges. Contact our technical-commercial team to select the reference best suited to your specialty and supply volume.

Additional information

Reference

COLT14

Gauge

14G (approx. 2.1 mm diameter)

Cutting system

Automatic double-fire guillotine

Available lengths

11 cm, 15 cm, 20 cm and 25 cm

Type of use

Disposable, single-use

Sterility

Yes, sterile presentation

Material

High-strength stainless steel and medical-grade polymer components

Application

Percutaneous soft tissue biopsy in radiology, oncology and surgery

Presentation

Sterile unit

Indications

Ultrasound-, CT- or fluoroscopy-guided biopsies in the liver, kidney, breast, thyroid, prostate and soft tissue masses

Reviews

There are no reviews yet.

Be the first to review “14G Automatic Biopsy Instrument with Guillotine System for Soft Tissue | Lengths 11, 15, 20 and 25 cm (Ref. COLT14)”