Description
1. Commercial Introduction
The 3 mm Ø skin biopsy punch with plunger, from the KAI line manufactured in Japan, is the reference instrument for the rapid, reliable and highly hygienic collection of tissue samples in dermatology, gynaecology and podiatry practice. Its very sharp circular stainless steel cutting edge allows a 3 mm cylindrical sample to be taken with a clean, regular cut and minimal trauma to the surrounding tissue, promoting rapid healing and a reliable histopathological report. As a sterile, single-use device, it eliminates the sharpening and sterilisation operations associated with reusable instruments, as well as the risk of cross-contamination.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the entire skin, including the full epidermis and dermis, for histopathological examination. The very sharp circular stainless steel cutting edge provides a smooth, regular cutting surface, allowing a clean incision with optimal specimen quality.
The distinctive feature of this reference is its plunger: after rotation of the punch and the circular incision, the plunger facilitates the removal and collection of the cylindrical sample, simplifying the extraction manoeuvre and avoiding damage to the tissue obtained. The ribbed handle ensures a firm grip and precise control during rotation, even with gloves, while the size printed on each unit allows immediate identification, preventing errors during the procedure. Each punch is individually sealed in a transparent peel-apart package, guaranteeing sterility until the moment of opening. It is a disposable, single-use device.
3. Technical Specifications
Disposable skin biopsy punch Ø 3 mm with plunger, with a blade length of 7 mm, very sharp stainless steel cutting edge and ribbed handle. Size printed on each unit for easy identification. Indicated for dermatology, gynaecology and podiatry. Each punch is individually sealed in a transparent peel-apart package. Manufactured in Japan.
| Characteristic | Detail |
|---|---|
| Product type | Disposable skin biopsy punch with plunger |
| Cutting diameter | 3 mm (Ø 3 mm) |
| Sheet length | 7 mm |
| Extraction device | Plunger to facilitate sample removal |
| Blade material | Very sharp stainless steel |
| Handle | Ribbed, firm grip |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual transparent peel-apart packaging |
| Sales unit | Box of 20 units |
| Use | Disposable, single-use |
| Application | Dermatology, gynaecology and podiatry |
| Origin | Japan (KAI line) |
| Manufacturer reference | 22634 (SKU Cahnos: GM22634) |
Product data
| Field | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | Box of 20 units |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Available references (KAI line family)
| Reference | Model | Sales unit |
|---|---|---|
| GM22610 | Biopsy punch Ø 1 mm | Box of 20 units |
| GM22611 | Biopsy punch Ø 1.5 mm | Box of 20 units |
| GM22612 | Biopsy punch Ø 2 mm | Box of 20 units |
| GM22613 | Biopsy punch Ø 2.5 mm | Box of 20 units |
| GM22614 | Biopsy punch Ø 3 mm | Box of 20 units |
| GM22615 | Biopsy punch Ø 3.5 mm | Box of 20 units |
| GM22616 | Biopsy punch Ø 4 mm | Box of 20 units |
| GM22617 | Biopsy punch Ø 5 mm | Box of 20 units |
| GM22618 | Biopsy punch Ø 6 mm | Box of 20 units |
| GM22619 | Biopsy punch Ø 8 mm | Box of 20 units |
| GM22630 | Biopsy punch with plunger Ø 1 mm | Box of 20 units |
| GM22634 | Biopsy punch with plunger Ø 3 mm (this reference) | Box of 20 units |
| GM22636 | Biopsy punch with plunger Ø 4 mm | Box of 20 units |
4. Equivalences and Cross-References
This Ø 3 mm punch with plunger belongs to the KAI line, manufactured in Japan by KAI Corporation, and shares the same technical principle as the sterile single-use skin biopsy punches on the market: circular stainless steel cutting edge, ribbed handle, size printed on each unit and individual sterile packaging. The manufacturer does not publish a validated 1:1 equivalence table, so the cross-references indicated are category comparisons checked against official catalogues and regulatory sources (GUDID) and must be confirmed with the technical department before use in tenders.
| Manufacturer / Brand | Reference code / SKU | Equivalence level |
|---|---|---|
| (KAI line, without plunger) | 22614 | Comparable by category (not interchangeable 1:1) |
| (Stiefel-type curette-punch) | 22584 | Comparable by category (same manufacturer, different line) |
| KAI Medical (KAI Corporation) | BP-30F | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | STIEF-BP3 / SZ1983 | Comparable by category (not interchangeable 1:1) |
| Integra Miltex (Integra LifeSciences) | 33-32 | Comparable by category (not interchangeable 1:1) |
Within the Cahnos catalogue, the homologous family in other brands (disposable punches from 2 to 8 mm) allows any gauge to be covered with guarantees, and reference 0100770 (disposable 3 mm punch in a box of 10) constitutes a comparable alternative by category.
5. Selection tips and variants of interest
The diameter of the punch determines the size of the sample and should be chosen according to the lesion and the intended histopathological study. The 3 mm gauge (this reference) is ideal for small lesions, aesthetic areas, mucous membranes and paediatric patients, providing a representative sample with a contained cosmetic defect.
The plunger variant is especially recommended when it is desired to facilitate and speed up the removal of the sample after the circular cut, reducing the risk of manipulation and preserving the integrity of the specimen. The KAI line range covers the full range of diameters with the same quality: 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm in standard version (GM22610 to GM22619), plus the plunger variants for Ø 1 mm (GM22630), Ø 3 mm (GM22634) and Ø 4 mm (GM22636). This allows the supplier to be standardised and stock of various gauges to be maintained in your dermatology, gynaecology, podiatry or minor ambulatory surgery service.
Always check the integrity of the individual package before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations. For large orders you can request a quote: consult your technical-commercial advisor at Cahnos for conditions, lead times and technical confirmation of equivalences.