Description
1. Commercial Introduction
The 2 mm skin biopsy punch with plunger, from the KAI line manufactured in Japan, is the ideal reference for the rapid, reliable and highly hygienic collection of tissue samples in dermatology, gynaecology and podiatry practice. Its very sharp circular stainless steel cutting edge allows a 2 mm cylindrical sample to be extracted with a clean, regular cut and minimal trauma to the surrounding tissue, which promotes rapid healing and a reliable histopathological report. As it is a sterile, single-use device, it eliminates the sharpening and sterilisation operations typical of reusable instruments, as well as the risk of cross-contamination.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the entire skin, including complete epidermis and dermis for histopathological study. The very sharp circular stainless steel cutting edge provides a smooth, regular cutting surface, allowing a clean incision with optimal specimen quality.
The particular feature of this reference is its plunger: after rotation of the punch and the circular incision, the plunger facilitates the exit and collection of the cylindrical sample, simplifying the extraction manoeuvre and avoiding damage to the tissue obtained. The ribbed plastic handle ensures a firm grip and precise control during rotation, even with gloves, while the size engraved on each unit allows immediate identification, avoiding errors during the procedure. Each punch is individually sealed in a transparent peel-apart package, guaranteeing sterility until the moment of opening. It is a disposable, single-use device.
3. Technical Specifications
Disposable 2 mm skin biopsy punch with plunger, with a 7 mm long blade, very sharp stainless steel cutting edge and ribbed handle. Size engraved on each unit for easy identification. Indicated for dermatology, gynaecology and podiatry. Each punch is individually sealed in a transparent peel-apart package. Manufactured in Japan (KAI line).
Technical features
| Characteristic | Detail |
|---|---|
| Product type | Disposable skin biopsy punch with plunger |
| Cutting diameter | 2 mm (Ø 2 mm) |
| Sheet length | 7 mm |
| Extraction device | Plunger to facilitate sample removal |
| Blade material | Very sharp stainless steel |
| Handle | Ribbed plastic, firm grip |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual transparent peel-apart packaging |
| Use | Disposable, single-use |
| Application | Dermatology, gynaecology and podiatry |
| Origin | Japan (KAI line) |
| Manufacturer reference | 22632 (SKU Cahnos: GM22632) |
Product data
| Field | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | Box of 20 units (box of 20 pcs) |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Available references (KAI line family)
| Reference | Model | Sales unit |
|---|---|---|
| GM22610 | Biopsy punch Ø 1 mm | Box of 20 units |
| GM22611 | Biopsy punch Ø 1.5 mm | Box of 20 units |
| GM22612 | Biopsy punch Ø 2 mm | Box of 20 units |
| GM22613 | Biopsy punch Ø 2.5 mm | Box of 20 units |
| GM22614 | Biopsy punch Ø 3 mm | Box of 20 units |
| GM22615 | Biopsy punch Ø 3.5 mm | Box of 20 units |
| GM22616 | Biopsy punch Ø 4 mm | Box of 20 units |
| GM22617 | Biopsy punch Ø 5 mm | Box of 20 units |
| GM22618 | Biopsy punch Ø 6 mm | Box of 20 units |
| GM22619 | Biopsy punch Ø 8 mm | Box of 20 units |
| GM22630 | Biopsy punch with plunger Ø 1 mm | Box of 20 units |
| GM22631 | Biopsy punch with plunger Ø 1.5 mm | Box of 20 units |
| GM22632 | Biopsy punch with plunger Ø 2 mm (this reference) | Box of 20 units |
| GM22634 | Biopsy punch with plunger Ø 3 mm | Box of 20 units |
| GM22636 | Biopsy punch with plunger Ø 4 mm | Box of 20 units |
4. Equivalences and Cross-References
This 2 mm punch with plunger belongs to the KAI line, manufactured in Japan by KAI Corporation, and shares the technical principle with sterile single-use skin biopsy punches on the market: circular stainless steel cutting edge, ribbed handle, size engraved on each unit and individual sterile packaging. The manufacturer does not publish a validated 1:1 equivalence table, so the cross-references indicated are category comparisons checked against official catalogues and regulatory sources (GUDID) and must be confirmed with the technical department before use in tendering.
| Manufacturer / Brand | Reference code / SKU | Equivalence level |
|---|---|---|
| (KAI line, without plunger) | 22612 (Ø 2 mm) | Comparable by category (not interchangeable 1:1) |
| (Stiefel-type punches) | GM22650 / STIEF-BP2 | Comparable by category (same distributor, different line) |
| KAI Medical (KAI Corporation) | BP-20F | Comparable by category (not interchangeable 1:1) |
| Cahnos (disposable 2 mm punch, box of 10) | 0100775 | Comparable by category (not interchangeable 1:1) |
Within the Cahnos catalogue, the homologous family in other brands (disposable punches from 2 to 8 mm) allows any gauge to be covered with guarantees. All references in this catalogue; consult your technical-commercial advisor at Cahnos for confirmation of equivalences, lead times and conditions. For large orders you can request a quote.
5. Selection tips and variants of interest
The diameter of the punch determines the size of the sample and must be chosen according to the lesion and the planned histopathological study. The 2 mm gauge (this reference) is ideal for very small lesions, aesthetic areas, mucous membranes and paediatric patients, providing a representative sample with a contained cosmetic defect.
The plunger variant is especially recommended when it is desired to facilitate and speed up the extraction of the sample after the circular cut, reducing the risk of manipulation and preserving the integrity of the specimen. The KAI line range allows the full range of diameters to be covered with the same quality: 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm in standard version (GM22610 to GM22619), plus the plunger variants for Ø 1 mm (GM22630), Ø 1.5 mm (GM22631), Ø 2 mm (GM22632), Ø 3 mm (GM22634) and Ø 4 mm (GM22636). This allows the supplier to be standardised and stock of several gauges to be maintained in your dermatology, gynaecology, podiatry or minor ambulatory surgery service.
Always check the integrity of the individual package before each use and dispose of the instrument after the procedure in accordance with healthcare waste regulations. Consult your technical-commercial advisor at Cahnos for conditions, lead times and technical confirmation of equivalences.