Description
1. Commercial Introduction
The Ø 2.5 mm skin biopsy punch, from the KAI line manufactured in Japan, is the reference instrument for obtaining small-calibre tissue samples in dermatology, gynaecology and podiatry clinics. Its very sharp circular stainless steel cutting edge allows a 2.5 mm cylindrical sample to be taken with a clean, regular cut and minimal trauma to the surrounding tissue, promoting rapid healing and a reliable histopathological report. Each punch is individually sealed in a transparent peel-apart package, and the box of 20 units facilitates stock maintenance in diagnostic services.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the skin, including complete epidermis and dermis for histopathological examination. The very sharp circular stainless steel cutting edge is provided on a 7 mm blade length, reaching sufficient depth for sample collection.
The grooved plastic handle provides a secure and stable grip even with gloves, while the size is engraved on each punch, preventing identification errors during the procedure. As a sterile, disposable, single-use device, it eliminates the sharpening and sterilisation tasks associated with reusable instruments and reduces the risk of cross-contamination in the clinic. The 2.5 mm diameter is ideal for small lesions, aesthetic areas and paediatric patients, providing a representative sample with a contained cosmetic defect.
3. Technical Specifications
Disposable skin biopsy punch Ø 2.5 mm, with 7 mm blade length, very sharp stainless steel cutting edge and grooved plastic handle. Size engraved on each unit for easy identification. Indicated for dermatology, gynaecology and podiatry. Each punch is individually sealed in a transparent peel-apart package. Manufactured in Japan.
Product data
| Field | Detail |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 22613 (SKU Cahnos: GM22613) |
| Sales unit | Box of 20 units |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Technical features
| Parameter | Specification |
|---|---|
| Product type | Disposable skin biopsy punch |
| Cutting diameter | 2.5 mm (Ø 2.5 mm) |
| Sheet length | 7 mm |
| Blade material | Very sharp stainless steel |
| Handle | Ribbed plastic (firm grip) |
| Identification | Size engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual heat-sealed transparent peel-apart packaging |
| Use | Disposable, single-use |
| Clinical areas | Dermatology, gynaecology and podiatry |
| Origin | Made in Japan (KAI line) |
Available references (KAI line family)
| Reference | Model | Sales unit |
|---|---|---|
| GM22610 | Biopsy punch Ø 1 mm | Box of 20 units |
| GM22611 | Biopsy punch Ø 1.5 mm | Box of 20 units |
| GM22612 | Biopsy punch Ø 2 mm | Box of 20 units |
| GM22613 | Biopsy punch Ø 2.5 mm (this reference) | Box of 20 units |
| GM22614 | Biopsy punch Ø 3 mm | Box of 20 units |
| GM22615 | Biopsy punch Ø 3.5 mm | Box of 20 units |
| GM22616 | Biopsy punch Ø 4 mm | Box of 20 units |
| GM22617 | Biopsy punch Ø 5 mm | Box of 20 units |
| GM22618 | Biopsy punch Ø 6 mm | Box of 20 units |
| GM22619 | Biopsy punch Ø 8 mm | Box of 20 units |
| GM22630 | Biopsy punch with plunger Ø 1 mm | Box of 20 units |
4. Equivalences and Cross-References
This Ø 2.5 mm punch belongs to the Biopsy Punches line manufactured in Japan (original reference PUNCH PER BIOPSIA KAI), characterised by a very sharp circular stainless steel cutting edge, grooved handle, 7 mm blade length and presentation in a box of 20 units with individual peel-apart packaging. The manufacturer does not publish a validated 1:1 equivalence table, so cross-references between manufacturers are technical comparisons by category and must be confirmed with the Cahnos technical-commercial department before use in tenders.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| Catalogue Cahnos | Stiefel-type biopsy-punch curette Ø 2.5 mm (box of 10 units, 8 mm blade) | 22583 | Comparable by category (same family, different presentation) |
| KAI Medical | Sterile biopsy punch BP series | BP series (e.g. BP-20F / BP-30F / BP-40F) | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | Stiefel Biopsy Punch | STIEF-BP / SZ198x series | Comparable by category (not interchangeable 1:1) |
| Integra Miltex (Integra LifeSciences) | Sterile Disposable Biopsy Punch | Series 33-3x | Comparable by category (not interchangeable 1:1) |
| Cahnos | Disposable skin biopsy punches (box of 10 units) | 0100770, 0100771, 0100772, 0100773 | Comparable by category (diameters in the same range) |
There is no equivalence table validated by the manufacturer; always confirm with your Cahnos technical-commercial advisor before replacing references in tenders or protocols.
5. Selection tips and variants of interest
The punch diameter determines the size of the sample obtained and should be chosen according to the lesion and the planned histopathological study. Diameters from 1 to 3 mm are reserved for small lesions, mucous membranes, aesthetic areas and paediatric patients, minimising scarring; the 2.5 mm diameter (this reference) is a very useful intermediate option for small lesions requiring a larger sample than the 2 mm diameter while maintaining a contained cosmetic defect; from 3.5 to 6 mm is the usual range in dermatology for most skin lesions; and the 8 mm diameter is the option for large lesions or studies requiring a large sample with complete epidermis and dermis.
The KAI line range covers the full range of diameters with the same quality and supplier (Ø 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm; refs. GM22610 to GM22619), allowing you to standardise the supplier and maintain stock of several diameters in your dermatology, gynaecology, podiatry or minor ambulatory surgery service. If sample extraction needs to be facilitated in small diameters, the variant with plunger is available for Ø 1 mm (Ref. GM22630). Always check the integrity of the individual package before each use: sterility is not guaranteed if the packaging is damaged. Dispose of the instrument after the procedure in accordance with healthcare waste regulations. For large orders you can request a quote: consult your Cahnos technical-commercial advisor for conditions, lead times and confirmation of equivalences.







Reviews
There are no reviews yet.