Description
1. Commercial Introduction
The Ø 8 mm skin biopsy punch, from the KAI line manufactured in Japan, is the reference instrument for obtaining large, representative skin tissue samples in dermatology, gynaecology and podiatry consultations. Its very sharp circular stainless steel cutting edge allows a cylindrical 8 mm sample to be extracted with a clean, regular cut and minimal trauma to the surrounding tissue, promoting rapid healing and a reliable histopathological report. Each punch is individually sealed in a peel-apart package, and the box of 20 units facilitates stock management in diagnostic services.
2. Technical explanation of the equipment and procedure
Punch biopsy is the technique of choice for obtaining a representative cross-section of the skin, including full epidermis and dermis for histopathological study. The circular stainless steel cutting edge is presented on a blade length of 7 mm, reaching sufficient depth for the study. The fluted handle offers a secure and stable grip even with gloves, while the size is engraved on each punch, preventing identification errors during the procedure.
Being a sterile, disposable, single-use device, it eliminates the sharpening and sterilisation tasks associated with reusable instruments and reduces the risk of cross-contamination in the clinic. The 8 mm diameter is particularly indicated for large lesions, more extensive excisions or studies requiring a voluminous sample.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 20 units |
| Device type | Medical device |
| Device class | II A |
| CND | A010299 |
| GMDN | 12734 |
Technical features
| Parameter | Specification |
|---|---|
| Manufacturer reference | 22619 (SKU Cahnos: GM22619) |
| Product type | Disposable skin biopsy punch |
| Cutting diameter | 8 mm (Ø 8 mm) |
| Sheet length | 7 mm |
| Blade material | Very sharp stainless steel |
| Handle | Fluted, firm grip |
| Identification | Measurement engraved on each punch |
| Sterility | Yes, sterile and ready to use |
| Presentation | Individual heat-sealed transparent peel-apart packaging |
| Use | Disposable, single-use |
| Clinical areas | Dermatology, gynaecology and podiatry |
| Origin | Made in Japan (KAI line) |
4. Equivalences and Cross-References
This punch belongs to the Biopsy Punches line manufactured in Japan (original reference PUNCH PER BIOPSIA KAI), characterised by a very sharp circular stainless steel cutting edge, fluted handle, 7 mm blade length and presentation in a box of 20 units with individual peel-apart packaging. Within the manufacturer’s own catalogue, reference 22590 (Ø 8 mm, box of 10 units, 8 mm blade) shares the same technical principle with a different presentation, so it can be considered comparable by category. Note: there is no validated 1:1 equivalence table from the manufacturer; cross-references between manufacturers are technical comparisons by category and must be confirmed with our technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| KAI Medical | Sterile Biopsy Punch (Ø 8.0 mm) | BP-80F | Comparable by category (not interchangeable 1:1) |
| Stiefel (GSK-Stiefel) | Stiefel Biopsy Punch Ø 8 mm | STIEF-BP8 / SZ1988 | Comparable by category (not interchangeable 1:1) |
| Catalogue Cahnos | Stiefel-type Biopsy-Punch Curette Ø 8 mm | 22605 | Comparable by category (same manufacturer, different line) |
| Catalogue Cahnos | Biopsy Punches Ø 8 mm (box of 10 units, 8 mm blade) | 22590 | Comparable by category (same family, different presentation) |
| Integra Miltex | Sterile Disposable Biopsy Punch | 33-37 | Comparable by category (not interchangeable 1:1) |
5. Selection tips and variants of interest
The diameter of the punch determines the size of the sample obtained and should be chosen according to the lesion and the intended histopathological study. Sizes from 1 to 3 mm are reserved for small lesions, mucous membranes, aesthetic areas and paediatric patients; 4 to 6 mm constitute the standard range in dermatology for most skin lesions; and the 8 mm size (this reference) is the option for large lesions, more extensive excisions or studies requiring a voluminous sample with full epidermis and dermis.
The KAI line range covers the full spectrum of diameters with the same quality and supplier (Ø 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and 8 mm). If sample extraction needs to be facilitated in small sizes, a variant with a plunger is available for Ø 1 mm (Ref. GM22630). Always check the integrity of the individual packaging before each use: sterility is not guaranteed if the packaging is damaged. Dispose of the instrument after the procedure in accordance with healthcare waste regulations. All products in this catalogue; consult your technical-commercial advisor at Cahnos for conditions, lead times and confirmation of equivalences. For large orders you can request a quote.







Reviews