Description
The 9G trephine needle for bone marrow biopsy is the ideal solution for obtaining bone tissue and bone marrow samples in diagnostic procedures. Available in 10 and 15 cm lengths, it combines a sharp cutting tip with an ergonomic design that facilitates the specialist’s work and reduces patient trauma. A trusted tool for haematology, oncology and clinical diagnostics services, where sample quality is decisive for the outcome of the anatomopathological study.
Technical explanation of the device and procedure
Bone marrow biopsy with a trephine needle is a percutaneous technique that allows obtaining a cylinder of spongy bone tissue and bone marrow for cytological, anatomopathological and microbiological study. The trephine-type design (Jamshidi style) integrates a cannula with a cutting edge and an internal stylet that facilitates penetration of the bone cortex; once the cannula is positioned, the stylet is removed and the sample is extracted by controlled rotational movements. The 9G gauge offers a generous sample diameter, ideal when a larger amount of tissue is required for a reliable diagnosis, while the single-use system eliminates the risk of cross-contamination and guarantees an always optimal cutting edge. The 15 cm length is especially indicated in patients with a larger panniculus adiposus, ensuring safe access to the posterosuperior iliac crest.
Technical specifications
| Characteristic | Specification |
| Gauge | 9G (approximately 3.8 mm external diameter) |
| Available lengths | 10 cm (100 mm) and 15 cm (150 mm) |
| Type | Disposable single-use trephine needle |
| Tip | Sharp cutting with internal trocar-type stylet |
| Material | Medical-grade stainless steel cannula |
| Presentation | Sterile unit |
| Intended use | Bone marrow biopsy and bone tissue sample collection |
| Compatibility | Standard trephine-type percutaneous biopsy techniques |
| Application areas | Haematology, oncology, clinical diagnostics |
| Variant | Gauge | Length | Recommended application |
| 9G trephine needle | 9G | 10 cm | Bone marrow biopsy in an adult of medium build (iliac crest) |
| 9G trephine needle | 9G | 15 cm | Patients with a larger panniculus adiposus or deep access to the iliac crest |
Equivalences and cross-references
This 9G trephine needle is functionally equivalent to the 9G Jamshidi-type bone marrow biopsy needles marketed with cannula and stylet systems for percutaneous puncture of the iliac crest. Among the references commonly used in this gauge and length, the Jamshidi system codes for 9G (pattern TJM4009 / DJ4009X) stand out, as well as the 9G x 100 mm and 9G x 150 mm variants from other bone biopsy instrument manufacturers, including the Sterylab NOLOSE 9G lines (BSL0910 and BSL0915) and the PARAGON 9G haematobiopsy needle of 15 cm. Compatibility is functional: same puncture technique, same gauge and same expected diagnostic results, without implying an exact equivalence of packaging or presentation.
Selection tips and variants of interest
For the selection of the appropriate gauge and length, the patient’s build and puncture site must be assessed. In adults of medium build, the 10 cm length is recommended, while the 15 cm version is indicated in overweight or obese patients to ensure safe access to the iliac crest. Since the 9G gauge provides a larger diameter sample cylinder, it is the preferred option when abundant bone tissue is required for complete histological studies; if a finer gauge and less invasiveness are required, the 11G trephine needle is available in the Cahnos catalogue. Consult our technical-commercial team to confirm availability, order volumes and special conditions for hospitals and distributors.