We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Arthroscopy irrigation pump tubing sets REGER · Tubing-Set compatible with LYNX-4K/HD Tower (Ref. 800-001-029, 800-002-029 and 800-003-029)

Price on request

Tubing sets (Tubing-Set) from REGER for arthroscopy irrigation pumps, specifically designed for the LYNX-4K/HD Tower system. Available in three versions: single-use (SUTS, Ref. 800-001-029), daily use (DUPP, Ref. 800-002-029) and patient part (SUPP, Ref. 800-003-029), allowing the irrigation circuit to be adapted to the protocol of each operating theatre and ensuring a constant and sterile flow of saline during the procedure. Original product from the manufacturer REGER Medizintechnik GmbH, supplied on quotation for professionals and B2B purchasing centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-BOMBA-TUBOS

Description

1. Commercial Introduction

Complete the circuit of your arthroscopy tower with the original tubing sets from REGER Medizintechnik GmbH, a leading German manufacturer of medical technology. These irrigation pump tubing sets are designed to work in an integrated manner with the LYNX-4K/HD Tower system, ensuring a stable, controlled and uninterrupted supply of saline during the arthroscopic procedure.

They are marketed in three variants differentiated by their usage regime and their position in the circuit, so that each centre can configure the most suitable consumable for its care needs and its sterilisation policy. At Cahnos we supply them on quotation for operating theatre fittings, trauma clinics and B2B purchasing centres.

2. Technical explanation of the equipment and procedure

In arthroscopy, the irrigation pump is responsible for maintaining joint distension and a clean visual field through the controlled supply of physiological saline. The tubing sets (Tubing-Set) constitute the hydraulic circuit that connects the saline bag or bottle to the pump and, from there, to the cannula or arthroscope that contacts the patient.

A correctly selected and perfectly maintained tubing set is essential to avoid air bubbles, pressure losses and flow fluctuations, minimising the risk of collapse of the joint cavity and ensuring optimal visibility throughout the procedure. The REGER range offers three complementary configurations: a single-use line (SUTS) for maximum safety and sterility for each patient; a daily-use line (DUPP) designed for continuous rotation of the service; and a patient part (SUPP) for the sections of the circuit in direct contact with the patient.

3. Technical Specifications

Specifications verified in the manufacturer’s catalogue (reger-medical.de, System Arthroscopy section):

Characteristic Value
Brand REGER
Manufacturer REGER Medizintechnik GmbH
Product type Irrigation pump tubing set (Tubing-Set)
System LYNX-4K/HD Tower
Application Arthroscopy irrigation

Available references

REGER reference Type Compatible with
800-001-029 Single-use (SUTS) LYNX-4K/HD Tower
800-002-029 Daily use (DUPP) LYNX-4K/HD Tower
800-003-029 Patient part (SUPP) LYNX-4K/HD Tower

4. Equivalences and Cross-References

This product belongs to the consumables range of the LYNX-4K/HD Tower system from the manufacturer REGER Medizintechnik GmbH (references 800-001-029, 800-002-029 and 800-003-029, together with their distribution SKUs RGR-800-001-029, RGR-800-002-029 and RGR-800-003-029).

No equivalence table validated by the manufacturer has been found in reliable sources that cross-references these references with specific codes from other suppliers on a 1:1 interchangeable basis. Therefore, they should not be considered direct third-party substitutions without prior technical validation. For mixed fittings or renewal of arthroscopy towers, it is recommended to check the compatibility of the irrigation circuit with the technical-commercial department of Cahnos before any substitution.

5. Selection tips and variants of interest

To choose the appropriate variant of REGER tubing set, consider the usage regime of your service: reference 800-001-029 (SUTS, single-use) is the recommended option for maximum sterility and patient-to-patient traceability; 800-002-029 (DUPP, daily use) is designed for continuous rotation of the reusable circuit according to the centre’s reprocessing protocol; and 800-003-029 (SUPP, patient part) is intended for the sections of the circuit in contact with the patient.

Always verify that your tower corresponds to the LYNX-4K/HD Tower system before placing the order and periodically inspect the reusable sections: cracks, deformations, opacity or loss of sealing are signs that the set must be replaced to preserve the irrigation pressure and flow. It is recommended to have a spare set per unit to avoid downtime in the operating theatre. This product is marketed on quotation: consult your technical-commercial advisor at Cahnos for B2B conditions, lead times and availability.

Additional information

Tipo

Un solo uso (SUTS), Uso diario (DUPP), Parte de paciente (SUPP)

Compatibility

LYNX-4K/HD Tower

System

LYNX-4K/HD Tower

REGER reference

800-001-029, 800-002-029, 800-003-029

Manufacturer

REGER Medizintechnik GmbH

Product type

Irrigation pump tubing set (Tubing-Set)

Application

Arthroscopy irrigation

Single-use reference suts

800-001-029

Daily use reference dupp

800-002-029

Patient part reference supp

800-003-029

Presentation

On request (no published price)

Reviews

There are no reviews yet.

Be the first to review “Arthroscopy irrigation pump tubing sets REGER · Tubing-Set compatible with LYNX-4K/HD Tower (Ref. 800-001-029, 800-002-029 and 800-003-029)”