We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Miller laryngoscope blade size 0 with conventional light (C.L.) in stainless steel, reusable (Ref. RIA53120 | SKU BRLRIA53120)

32,47 €

Laryngoscope blade (blade) of straight profile Miller, size 0, with illumination by conventional light (C.L.) in stainless steel. Designed for direct laryngoscopy and orotracheal intubation in neonatal patients, its straight geometry allows direct elevation of the epiglottis and exposure of the glottis with a clear and stable view of the glottic plane. Reusable, robust instrument suitable for the cleaning, disinfection and sterilisation cycles of the hospital environment, compatible with conventional light laryngoscope handles according to the ISO 7376 system. Ideal for anaesthesiology, neonatology, paediatrics, emergency, critical care and airway trolleys. Class I medical device conforming to Regulation (EU) 2017/745 (MDR). References RIA53120 / BRLRIA53120. For large orders you can request a quote: request terms from our technical-commercial team.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLRIA53120

Description

1. Commercial Introduction

The Miller straight-profile laryngoscope blade, size 0, with conventional light (C.L.) system is the reusable stainless steel option for direct laryngoscopy and orotracheal intubation in neonatal patients. Designed for anaesthesiology, neonatology, paediatrics, emergency, critical care units, resuscitation and airway trolleys, it offers a robust metal construction with a reliable fit on the laryngoscope handle, ensuring stability and precision in every procedure. Being reusable, it offers an excellent cost-benefit ratio in high-turnover care settings. For large orders you can request a quote: contact the technical-commercial department of Cahnos to request terms and availability.

2. Technical explanation of the equipment and procedure

Direct laryngoscopy with a Miller-type blade is the classic straight-profile technique for endotracheal intubation: the straight blade is inserted and directly lifts the epiglottis, exposing the glottis and facilitating the passage of the endotracheal tube. Size 0 is specifically designed for the reduced anatomy of the neonatal patient, where an inadequate blade would compromise visualisation and increase the risk of injury; its reduced length allows stable, minimally traumatic handling.

This blade uses a conventional lighting system (C.L.): the light is generated in the handle and projected directly onto the working field, without the need for a fibre-optic guide. Made entirely of stainless steel, it is a highly robust reusable device that withstands the usual hospital cleaning, disinfection and sterilisation cycles, maintaining full mechanical and lighting performance.

3. Technical Specifications

Reusable straight-profile Miller laryngoscope blade (blade), size 0, with conventional light (C.L.) illumination and stainless steel body, designed for direct laryngoscopy and orotracheal intubation in neonatal patients.

Available references Description
RIA53120 Conventional Light Miller Blade Size 0 – Original manufacturer reference
BRLRIA53120 Conventional Light Miller Blade Size 0 – SKU Cahnos (same product)
Characteristic Specification
Manufacturer Boscarol
Product type Reusable laryngoscope blade
Profile Miller (straight)
Size 0
Material Stainless steel
Illumination system Conventional light (C.L.)
Target population Neonates and newborns
Reuse Yes (reusable)
Compatibility Conventional light laryngoscope handles (system ISO 7376)
Device class Class I medical device
Regulatory standard Regulation (EU) 2017/745 (MDR)
Category Respiration and Emergency

4. Equivalences and Cross-References

This blade is identified in the manufacturer’s catalogue by reference RIA53120, which in Cahnos corresponds to SKU BRLRIA53120 (same product, dual coding). It is part of the manufacturer’s range of conventional light (C.L.) straight-profile Miller blades, available in sizes 0, 1, 2, 3 and 4, as well as in the fibre-optic (O.F.) version of the same family in sizes 0 to 3.

Within the same catalogue there are verified related references: the C.L. Miller blade size 1 (RIA53122 / BRLRIA53122), size 2 (RIA53124 / BRLRIA53124), size 3 (RIA53126 / BRLRIA53126) and size 4 (RIA53128 / BRLRIA53128); the Miller fibre-optic blades (e.g. size 0, RIA53320 / BRLRIA53320, and size 2, RIA53324 / BRLRIA53324); the C.L. set of 3 Miller blades 1-2-3 (RIA53104 / BRLRIA53104); the paediatric conventional light handle (RIA53130 / BRLRIA53130) and the lighting spare parts of the range (C.L. bulbs ref. RIA53180 for small blade and RIA53182 for large blade). There is no 1:1 equivalence table validated by the manufacturer against third-party codes (e.g. Heine, Penlon, Riester or KaWe); before replacing blades from another brand, it is essential to verify the connection fit (standard ISO 7376), the profile and the size with the corresponding laryngoscope handle, and to cross-check the reference with the technical-commercial department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Select the blade size according to the patient’s age and anatomy: size 0 (this reference) is reserved for neonates and newborns, size 1 for infants and young children, size 2 for older children and small adults, size 3 for most adult patients and size 4 for tall or large-built adults. The Miller straight profile is especially recommended when direct elevation of the epiglottis is preferred; for patients where indirect elevation via support on the vallecula is preferred, the MacIntosh series constitutes a complementary alternative within the same family.

To fully equip your airway trolley, combine several sizes from the same reusable C.L. family and always use a compatible conventional light laryngoscope handle, keeping spare bulbs (ref. RIA53180 for small blade and RIA53182 for large blade) so that the equipment is always operational. Always verify the correct alignment and blade-handle fit before each procedure and follow the recommended cleaning, disinfection and sterilisation cycles for stainless steel instruments. For complete equipment, tenders or special supply conditions, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

RIA53120

Product type

Reusable laryngoscope blade

Profile

Miller (straight)

Size

0

Lighting system

Conventional light (C.L.)

Target population

Neonates and newborns

Reuse

Yes (reusable)

Compatibility

Conventional light laryngoscope handles (system ISO 7376)

Device class

Class I medical device

Regulatory standard

Regulation (EU) 2017/745 (MDR)

Material

Stainless steel

Documentation

Reviews

There are no reviews yet.

Be the first to review “Miller laryngoscope blade size 0 with conventional light (C.L.) in stainless steel, reusable (Ref. RIA53120 | SKU BRLRIA53120)”

Your email address will not be published. Required fields are marked *