We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Contiplex® Tuohy Ultra 360 NRFit® Set (B. Braun) – Catheter through 18 G Tuohy-bevel needle for continuous peripheral nerve blockade guided by ultrasound and neurostimulation, NRFit® connection (box of 10 units)

669,63 €

Continuous regional anaesthesia set for plexus and peripheral nerve blockade with catheter through an 18 G Tuohy-bevel needle and Ultra 360 echogenic technology: 360° reflective marker pattern ensuring needle visibility under ultrasound from any position, ergonomic hub with neurostimulator connection and lateral port for simultaneous injection/suction during catheter placement. Includes Contiplex® Ultra echogenic catheter (20 G) with 6 lateral holes, connector and 0.2 µm Perifix® filter, Perifix® PinPad and infusion extension line, all with NRFit® connection (ISO 80369-6). Sterile (EO), single-use, latex-free and DEHP-free. Sold in boxes of 10 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BBR-CONTIPLEX-TUOHY-ULTRA-360-NRFIT

Description

1. Introduction

The Contiplex® Tuohy Ultra 360 NRFit® set from B. Braun is the continuous regional anaesthesia solution for anaesthesiology departments, pain units and enhanced recovery protocols (ERAS). Its catheter-through-needle design with Tuohy bevel allows peripheral plexuses and nerves to be located using dual guidance (ultrasound imaging and neurostimulation) and leaves a stable local anaesthetic infusion line in place for prolonged postoperative analgesia.

The entire infusion line incorporates the NRFit® safety connection (ISO 80369-6), which prevents any incorrect connection with Luer systems from other lines. It is the variant of the Contiplex® Tuohy Ultra 360 family with NRFit® connectors, intended for hospitals that work with NRFit® syringes, three-way stopcocks and infusion circuits.

2. Technical explanation of the equipment and procedure

The set is based on a catheter-through-needle system: the Contiplex® puncture needle of 18 G, with Tuohy bevel and insulating coating, allows optimal puncture and advancement. Its exclusive echogenic design, with a pattern of reflective markers arranged at 360°, ensures clear visualisation of the needle and its tip from any position during ultrasound control. The safety code facilitates immediate identification of the tip, and the ergonomic hub provides excellent tactile sensitivity, with depth marks offering direct visual feedback (graduation every 1 cm).

Once the target structure has been located by neurostimulation and/or ultrasound imaging, the echogenic Contiplex® Ultra catheter is advanced through the needle. The adaptable side port allows simultaneous injection/aspiration of the local anaesthetic with catheter placement without having to manipulate the assembly. The system is completed with the adhesive label identifying the catheter location, the Perifix® catheter connector with NRFit® connection, the Perifix® 0.2 µm filter, the Perifix® PinPad (adhesive fixation of the filter) and the infusion extension line with NRFit® connection.

3. Technical Specifications

Characteristic Specification
Product type Catheter-through-needle set (puncture needle)
Application cPNB – continuous anaesthetic block of plexuses and peripheral nerves
Puncture needle Contiplex® 18 G, outer diameter 1.30 mm, Tuohy bevel, insulating coating, graduated every 1 cm
Ultrasound visibility Reflective marker at 360° (Ultra 360) and tip safety code
Connection NRFit® according to ISO 80369-6 (needle, syringe, connector, filter and extension line)
Catheter Echogenic Contiplex® Ultra, 20 G gauge, outer diameter 0.85 mm, inner diameter 0.45 mm, 6 side holes
Catheter material PUR, PA
Filter Perifix® 0.2 µm with NRFit® connection; priming volume 0.45 ml
Maximum pressure 7.0 bar
Syringe included 1 x Omnifix 5 ml NRFit – Lock
Catheter connector included Yes (Perifix® with NRFit® connection)
PinPad included Yes (Perifix® PinPad)
Additional components Adhesive identification label, infusion extension line with NRFit® connection
Packaging Sterile blister
Contains PVC / latex / DEHP PVC: yes / latex: no / DEHP: no
Use Single-use
Sterility / sterilisation Sterile / ethylene oxide (EO)
Presentation Box of 10 units

Available references

The references differ in the length of the needle and that of the associated catheter:

Reference Description Gauge Needle length Catheter Presentation
4898705NR-01 CONTIPLEX TUOHY ULTRA 360 G18 1.3X50MM N 18 G (Ø 1.30 mm) 50 mm (2″) 20 G – 400 mm (outer Ø 0.85 mm / inner Ø 0.45 mm) Box of 10 units
4898704NR-01 CONTIPLEX TUOHY ULTRA 360 G18 1.3X40MM N 18 G (Ø 1.30 mm) 40 mm (1 1/2″) 20 G – 400 mm (outer Ø 0.85 mm / inner Ø 0.45 mm) Box of 10 units
4898710NR-01 CONTIPLEX TUOHY ULTRA 360 G18 1.3X100MM 18 G (Ø 1.30 mm) 100 mm (4″) 20 G – 1010 mm (outer Ø 0.85 mm / inner Ø 0.45 mm) Box of 10 units
4898715NR-01 CONTIPLEX TUOHY ULTRA 360 G18 1.3X150MM 18 G (Ø 1.30 mm) 150 mm 20 G (Ø ext. 0.85 mm / Ø int. 0.45 mm) Box of 10 units

4. Equivalences and Cross-References

Within the Contiplex® family from B. Braun, the NRFit® version (this set) differs from the standard Contiplex® Tuohy Ultra 360 version exclusively by incorporating NRFit® safety connectors (ISO 80369-6) throughout the infusion line: the version with Luer connection performs the same clinical function but is not interchangeable 1:1 with NRFit® systems.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Observations
B. Braun Contiplex® Tuohy Ultra 360 (Luer version, without NRFit®) — Comparable by category (not interchangeable 1:1) Same catheter-through-needle system and Tuohy bevel, but with Luer connection: incompatible with syringes and NRFit® systems ISO 80369-6.
B. Braun Contiplex® S Ultra 360 NRFit® — Comparable by category (not interchangeable 1:1) Same NRFit® family with 360° echogenic needle; 20° bevel instead of Tuohy.
B. Braun Contiplex® C NRFit® 4898115NR / BBR4898115NR Comparable by category (not interchangeable 1:1) Catheter-over-needle system (25 G) with NRFit® connection; different placement technique.
Teleflex (Arrow) StimuCath™ Continuous Peripheral Nerve Block Set AB-19608-S Comparable by category (not interchangeable 1:1) Complete continuous block system with stimulating catheter and introducer; verify configuration, gauges and connection before replacing.

There is no equivalence table officially validated by the manufacturer for cross-referencing these references with other brands; the indicated correspondences are offered as guidance by category. Before any substitution in tenders or for an alternative brand, consult the technical department to verify gauges, lengths, bevel and connector compatibility.

5. Selection tips and variants of interest

  • Choice of needle length: the 40 and 50 mm references (4898704NR-01 and 4898705NR-01) cover superficial approaches such as brachial plexus, femoral or peripheral nerves in patients with thin tissue; the 100 mm (4898710NR-01) and 150 mm (4898715NR-01) ones are reserved for deep blocks or patients with greater adipose tissue.
  • NRFit® connection: choose this set if your hospital works with NRFit® syringes, three-way stopcocks and infusion circuits (ISO 80369-6). If your material inventory is Luer, consider the standard Contiplex® Tuohy Ultra 360 version.
  • Guidance technique: the set is prepared for dual guidance (ultrasound imaging + neurostimulation), thanks to the 360° echogenic needle and direct connection to the neurostimulator; the Tuohy bevel facilitates catheter direction in catheter-through-needle approaches.
  • Manufacturer variants: for continuous block with 20° bevel consider the Contiplex® S Ultra 360 NRFit® set; for a 25 G catheter-over-needle system, consider the Contiplex® C NRFit® set.
  • Compatibility: for an optimal and safe connection between the neurostimulator and the needle, the manufacturer recommends combining products from the same brand; consult the instructions for use (IFU).
  • Single-use: sterile single-use product; check the integrity of the packaging and the expiry date before each procedure. It is marketed in boxes of 10 units.

Additional information

Brand

B. Braun

Application

cPNB – continuous plexus and peripheral nerve block

Graduations

Graduated every 1 cm

Packaging

Blister

Catheter gauge (G)

20

Filter priming volume

0.45 ml

Filter pore size

0.2 µm

Syringes included

1 x Omnifix 5 ml NRFit – Lock

Catheter connector included

Yes

PinPad included

Yes

Sterility

Sterile (EO)

Sterilisation

EO

Presentation

Box of 10 units

Longitud

50 mm, 100 mm, 40 mm, 150 mm

Product type

Catheter-through-needle set (puncture needle)

Bevel type

Tuohy

Needle gauge

18 G

Needle outer diameter

1.30 mm

Available lengths

40 mm, 50 mm, 100 mm, 150 mm

Catheter gauge

20 G

Catheter outer diameter

0.85 mm

Catheter inner diameter

0.45 mm

Catheter length

400 mm (refs. 40/50 mm), 1010 mm (ref. 100 mm)

Catheter material

PUR, PA

Catheter holes

6 side holes

Connection

NRFit® (ISO 80369-6)

Filter

Perifix® 0.2 µm – priming volume 0.45 ml

Maximum pressure

7.0 bar

Syringe included

1 x Omnifix 5 ml NRFit – Lock

Catheter connector

Yes (Perifix® NRFit®)

Pinpad

Yes (Perifix® PinPad)

Contains PVC

Yes

Contains DEHP

No

Diametro mm

13 mm

G

18G

Latex

Latex-free

Tipo uso

Single-use

Documentation

Reviews

There are no reviews yet.

Be the first to review “Contiplex® Tuohy Ultra 360 NRFit® Set (B. Braun) – Catheter through 18 G Tuohy-bevel needle for continuous peripheral nerve blockade guided by ultrasound and neurostimulation, NRFit® connection (box of 10 units)”

Your email address will not be published. Required fields are marked *