Description
1. Introduction
The 7 cm Guedel oropharyngeal airway (ref. 5001 / SKU BRL5001) is an essential airway device in basic airway management for patients with loss of consciousness, deep sedation or general anaesthesia. Thanks to its anatomical polyethylene design, sterile, single-use and latex- and phthalate-free, it prevents the tongue and soft tissues from collapsing against the pharyngeal wall, ensuring a patent airway throughout the procedure. It is the ideal solution for emergency departments, intensive care, anaesthesia, cardiopulmonary resuscitation and patient transport.
2. Technical explanation of the device
The Guedel oropharyngeal airway (also known as the Mayo tube) is a curved semi-rigid tube inserted through the mouth into the oropharynx. Its anatomical curvature reproduces the morphology of the palate and pharynx, separating the tongue from the posterior pharyngeal wall and keeping the upper airway open in patients who cannot maintain it themselves. The central channel with lateral reinforcements ensures a continuous and stable airflow, while also allowing suction of secretions, and the integrated bite block protects the device from occlusion by bite pressure.
Being a sterile, single-use product, it prevents cross-contamination between patients. It should only be used in unconscious patients or those with depressed consciousness, and never in conscious patients with a gag reflex. The 7 cm (70 mm) size corresponds to an intermediate step in the range, indicated for older children, small-built adolescents and patients with medium-length oropharyngeal airways.
3. Technical Specifications
Sterile single-use medical device for maintaining oropharyngeal airway patency. Its main specifications are detailed below:
| Characteristic | Specification |
|---|---|
| Designation | Guedel oropharyngeal cannula (oropharyngeal airway) |
| Available references | 5001 / BRL5001 |
| Manufacturer | Boscarol |
| Length / size | 7 cm (70 mm) |
| Minimum internal diameter (I.D.) | 4.0 mm |
| Material | Polyethylene (PE), latex- and phthalate-free |
| Sterility | Yes, sterile single-use device |
| Function | Maintain the patency of the oropharyngeal cavity |
| Use | Single-use (disposable), prevents cross-contamination |
| Indication | Older children, small-built adolescents and medium-length oropharyngeal airways |
| Applications | Emergency care, anaesthesia, ICU, CPR and medical transport |
| Regulatory standard | Medical device with CE marking |
Range of available sizes (oropharyngeal cannulas):
| Reference | Length | Minimum I.D. |
|---|---|---|
| BRL5000 | 6 cm | 4.0 mm |
| BRL5001 | 7 cm | 4.0 mm |
| BRL5002 | 8 cm | 4.5 mm |
| BRL5003 | 9 cm | 4.5 mm |
| BRL5004 | 10 cm | 5.0 mm |
| BRL5005 | 11 cm | 5.5 mm |
4. Equivalences and Cross-References
References 5001 (original manufacturer code) and BRL5001 (SKU Cahnos) correspond to the same product, thus constituting a direct equivalence, without transcriptions or modifications. There is no official equivalence table validated by the manufacturer against other commercial brands for this reference; please consult our technical department before using it in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
|---|---|---|---|
| Catalogue Cahnos | Oropharyngeal airway 7 cm (this item) | 5001 / BRL5001 | Original reference |
| Cahnos | Guedel airway ISO7 (7 cm), non-sterile unit | 830010M | Comparable by size (not interchangeable 1:1) |
| Cahnos | Guedel Soft airway ISO7 (7 cm), flexible | SGU241070 | Comparable by category (material variant) |
| Gima | Guedel Airway 70 mm, size 1, white | 57754 | Comparable by category (same size) |
Sizing note: the classic numbering varies by manufacturer (70 mm may be associated with ‘size 1’ or ‘size 1.5’). Always verify the length in millimetres, the material, sterility and bite block design before replacing a reference in your airway trolley.
5. Selection tips and variants of interest
To choose the correct oropharyngeal airway size, measure the distance between the labial commissure and the angle of the patient’s mandible: the airway length should approximate this distance without exceeding it. The 7 cm (70 mm) size fits medium-length oropharyngeal airways; for smaller patients consider the smaller sizes in the range (4 to 6 cm, refs. 5110, 5100, 5010 and BRL5000) and for larger patients the larger sizes (8 to 11 cm, refs. BRL5002 to BRL5005).
It is recommended to lubricate the airway before insertion and place it with a 180-degree rotation to minimise trauma; the device should only be used in unconscious patients or those with depressed consciousness, never in conscious patients with a gag reflex. Consult our technical-commercial team for volumes, supply conditions and configuration of airway kits adapted to your anaesthesia, emergency, ICU or patient transport service. For large orders you can request a quote.