We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Guedel Airway ISO4 (4 cm) – Oropharyngeal Airway Device for Anaesthesia, Resuscitation and Emergency Care | Ref. 830001M

4,39 €

Guedel airway ISO4 (4 cm), reference 830001M: oropharyngeal airway device made of rigid, anatomical medical plastic, indicated to maintain respiratory patency in unconscious or anaesthetised patients during cardiopulmonary resuscitation, general anaesthesia and medical emergencies. It separates the tongue from the posterior pharyngeal wall and ensures continuous airflow during ventilation with a self-inflating bag and suction of secretions. The ISO4 size (40 mm) is recommended for paediatric patients and reduced oropharyngeal anatomies. Single-use product, supplied per unit, ideal for crash carts, operating theatres, ICU and medical transport.

International shipping. Import duties and taxes are payable by the recipient.

Reference
830001M

Description

1. Introduction

The Guedel airway ISO4 4 cm (ref. 830001M) is an oropharyngeal airway medical device designed to keep the airway open in unconscious, sedated or anaesthetised patients. Essential in cardiopulmonary resuscitation, general anaesthesia and prehospital care, it offers healthcare professionals a fast, reliable and easy-to-place resource to ensure adequate patient oxygenation in any critical scenario. Its ISO4 size (4 cm) makes it the ideal choice for young paediatric patients or those with a reduced oropharyngeal anatomy.

2. Technical explanation of the device

The Guedel oropharyngeal airway works by preventing the tongue and soft tissues from collapsing against the posterior pharyngeal wall, keeping the airway patent during ventilation with a self-inflating bag, anaesthetic induction or cardiopulmonary resuscitation. It is made of rigid medical plastic with an anatomical curve that reproduces the morphology of the palate and pharynx; its central channel and lateral reinforcements ensure a continuous and stable airflow, as well as facilitating suction of secretions. It is a single-use, disposable product that prevents cross-contamination between patients. The ISO4 size, with a length of 4 cm (40 mm), is indicated for paediatric patients and reduced oropharyngeal anatomies.

3. Technical Specifications

Parameter Specification
Reference 830001M
Size / model ISO4
Length 4 cm (40 mm)
Material Medical plastic, rigid and anatomical
Use Oropharyngeal airway maintenance
Application Emergency care, anaesthesia and resuscitation
Function Prevents tongue obstruction and ensures airflow
Indication Paediatric patients and reduced anatomies
Presentation Unit
Type of use Single-use (disposable)

This reference is part of Cahnos’s range of standard-rigidity Guedel airways, available in progressive sizes:

Reference Size
830001M ISO4 (4 cm)
830002M ISO5 (5 cm)
830003M ISO6 (6 cm)
830010M ISO7 (7 cm)
830020M ISO8 (8 cm)
830030M ISO9 (9 cm)
830040M ISO10 (10 cm)
830050M ISO11 (11 cm)
830060M ISO12 (12 cm)

4. Equivalences and Cross-References

The ISO4 size (4 cm) follows the length-based coding system in centimetres used by most manufacturers in the sector for oropharyngeal airways (progressive sizes from 3 to 12 cm according to airway management standards), which facilitates direct replacement in crash carts and standardised protocols. As a lower-rigidity alternative in the same size, Cahnos offers the Guedel Soft Airway ISO4 (ref. SGU241040), made of flexible polymer with an atraumatic tip, recommended for paediatric patients or those with sensitive oral tissues. For high-consumption programmes, the sterile 4 cm oropharyngeal airway is also available in a box of 50 units (ref. 5100). The fibre-optic range (refs. SLT253080, SLT253090 and SLT253100) complements the airway cart when correct placement needs to be verified under low visibility.

5. Selection tips and variants of interest

To choose the correct Guedel airway size, measure the distance between the corner of the mouth and the angle of the patient’s mandible: the length of the airway should approximate this distance without exceeding it. The ISO4 size (4 cm) fits infants and young paediatric patients; complete the supply with the adjacent sizes ISO3 (ref. SGU241030 in Soft version) and ISO5 (ref. 830002M) to have a complete sequence in the paediatrics or emergency care department. It is recommended to lubricate the airway before insertion and place it with a 180-degree rotation to minimise trauma. In patients with fragile mucosa, consider the Soft version (ref. SGU241040), and for adult patients the range from ISO9/ISO10. Consult our technical-commercial team for volumes, supply conditions and airway kits adapted to your anaesthesia, emergency, ICU or medical transport service.

Additional information

Reference

830001M

Model size

ISO4

Length

4 cm (40 mm)

Material

Medical plastic, rigid and anatomical

Use

Oropharyngeal airway maintenance

Application

Emergency care, anaesthesia and resuscitation

Function

Prevents tongue obstruction and ensures airflow

Indications

Paediatric patients and reduced anatomies

Type of use

Single-use (disposable)

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Guedel Airway ISO4 (4 cm) – Oropharyngeal Airway Device for Anaesthesia, Resuscitation and Emergency Care | Ref. 830001M”

Your email address will not be published. Required fields are marked *