Anaesthetic Face Mask with Valve for Neonate – Soft Anatomical Seal, Latex-free (Ref. AMAC23010V)

63,14 €

Anaesthesia mask with valve for neonates (ref. AMAC23010V), designed to achieve a soft, anatomical and effective seal in newborns during the administration of anaesthetic gases and assisted ventilation. Made of medical-grade, transparent, hypoallergenic and latex-free material, it adapts comfortably to the baby’s face without generating excessive pressure on its sensitive skin and minimises the risk of leaks. Compatible with standard anaesthesia circuits, self-inflating bags and hospital ventilators, it is the ideal option for operating theatres, neonatal units, emergency and intensive care. Hospital quality for professional B2B purchases.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMAC23010V

Description

The Neonatal Anaesthesia Mask with Valve (ref. AMAC23010V) is the recommended airway device for the safe and controlled administration of anaesthetic gases and ventilatory support in newborn patients. Its neonatal size and anatomical design ensure a comfortable fit on the baby’s face, with an effective seal that prevents leaks without generating excessive pressure. A reliable, soft and precise solution for anaesthetists and healthcare professionals who care for the smallest patients in the operating theatre, neonatal units, emergency and intensive care.

Technical explanation of the equipment

This mask incorporates an integrated one-way valve that regulates the passage of gas and ensures a constant and controlled flow throughout the ventilatory cycle, favouring both spontaneous and assisted ventilation. Its anatomical body, made of medical-grade, soft, transparent and latex-free material, adapts to the facial contour of the neonate, protects its sensitive skin and minimises pressure injuries even during prolonged procedures. The transparent body also facilitates continuous patient monitoring (colour, condensation or vomiting), while its connection is compatible with the standard anaesthesia circuits, self-inflating bags and ventilators used in the hospital setting, ensuring efficient gas administration throughout the procedure.

Technical specifications

The technical specifications of the product are summarised in the following table:

Parameter Specification
Reference AMAC23010V
Size Neonate (size 0/1)
Patient type Newborn / neonate
Design Anatomical, with unidirectional valve
Valve Integrated one-way, safe and controlled flow
Material Medical grade, soft, transparent and latex-free
Application Administration of anaesthesia and ventilation in newborns
Function Effective and safe seal for the supply of anaesthetic gases
Areas of use Operating theatre, neonatal units, emergency and intensive care
Presentation Unit (professional purchase format)

Indicative size chart for the air cushion with valve family:

Size Patient type Reference Cahnos
0/1 Newborn AMAC23010V (this product)
2 Paediatric AMAC23012V
3 Small adult AMAC23013V
4 Medium adult AMAC23014V
5 Large adult AMAC23015V

Equivalences and cross-references

Ref. AMAC23010V belongs to the family of anaesthesia masks with valve and air cushion. Its equivalent in the 360° rotation range for neonates is the AMAC23020V, also available as AMR23020V (Rotary Mask with Valve Size 0 Neonate), with which it shares size and patient profile. As an alternative from the non-rotating valve range for older patients, the AMC23012V (Paediatric Anaesthesia Mask with Valve) may be considered, at a lower cost and without a rotating connector. This neonatal size corresponds to the standard numbering of facial anaesthesia masks used by the main manufacturers in the sector, which facilitates its replacement in already installed circuits and allows the homogenisation of the service’s airway material.

Selection tips and variants of interest

Select the size according to the patient’s age and facial anatomy: reserve this neonatal size for newborns and low-weight infants, and use sizes 2 to 5 of the family for paediatric and adult patients. Always check the correct placement and sealing of the mask before each use: an adequate fit prevents leaks and improves the effectiveness of ventilation and gas administration. If your service seeks maximum circuit manoeuvrability, consider the versions with rotating connector AMAC23020V or AMR23020V. For volume purchases, periodic replenishment or the configuration of a complete size mix for your centre, our commercial team will advise you to ensure continuous availability with the best conditions.

Additional information

Reference

AMAC23010V

Size

Neonate (size 0/1)

Patient type

Newborn

Design

Anatomical with one-way valve

Valve

Integrated one-way, safe and controlled flow

Material

Medical grade, soft, transparent and latex-free

Application

Administration of anaesthesia and ventilation in newborns

Connection

Compatible with standard anaesthesia circuits, self-inflating bags and ventilators

Areas of use

Operating theatre, neonatal units, emergency and intensive care

Presentation

Unit (professional purchase format)

Latex

Latex-free

Documentation

Reviews

There are no reviews yet.

Be the first to review “Anaesthetic Face Mask with Valve for Neonate – Soft Anatomical Seal, Latex-free (Ref. AMAC23010V)”

Your email address will not be published. Required fields are marked *