Description
1. Introduction
The 8.5 mm cuffed endotracheal tube is a single-use airway management device designed for oral or nasal intubation of large adult patients. Made from thermosensitive polyvinyl chloride (PVC), it adapts gently to body temperature, combining the stability required for guided placement with the flexibility needed for comfortable stay during ventilation. It is the perfect ally for the operating theatre, intensive care units, emergency departments and resuscitation, where the airtight seal of the cuff ensures safe and effective positive-pressure ventilation, minimising leaks and the risk of aspiration.
2. Technical explanation of the equipment and procedure
In tracheal intubation, the tube is inserted orally or nasally under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs through its standard 15M connector. This model incorporates a low-pressure, high-volume cuff, inflated via the blue pilot balloon with Luer connection and one-way valve, which creates an atraumatic seal against the tracheal wall: it allows positive-pressure ventilation without significant leaks and prevents aspiration of secretions. The Murphy eye, a distal lateral orifice with rounded edges, acts as an alternative ventilation route if the main lumen becomes obstructed; the pre-curved, atraumatic Magill tip (conforming to applicable ISO/EN standards) facilitates injury-free advancement, and the radiopaque line, together with the depth graduation, allows radiographic verification of the tube’s position relative to the vocal cords. It is a disposable single-use product: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the data published in the manufacturer’s catalogue for this reference:
| Parameter | Specification |
| Manufacturer | Boscarol |
| Manufacturer reference / SKU Cahnos | ETAN85C02 / BRLETAN85C02 |
| Type | Endotracheal tube with cuff, oral/nasal (oronasal) use, Magill-type curve |
| Inner diameter | 8.5 mm |
| Material | Thermosensitive polyvinyl chloride (PVC) |
| Cuff | Low pressure, high volume, atraumatic |
| Indicator balloon | Blue, with Luer connection and one-way valve |
| Connector | 15M (standard) |
| Murphy eye | Yes, with atraumatic rounded edge |
| Tip | Atraumatic pre-curved Magill, conforming to applicable ISO/EN standards |
| Marking | Graduated with depth marks (verification relative to the vocal cords) and radiopaque line for clear identification under X-ray |
| Use | Single-use, disposable |
| Indications | Positive-pressure ventilation; anaesthesia induction if a face mask cannot be used; suction and protection of tracheal and bronchial secretions |
Available references from the ETAN…C02 range
| Reference | Inner diameter |
| ETAN35C02 / BRLETAN35C02 | 3.5 mm |
| ETAN55C02 / BRLETAN55C02 | 5.5 mm |
| ETAN60C02 / BRLETAN60C02 | 6.0 mm |
| ETAN65C02 / BRLETAN65C02 | 6.5 mm |
| ETAN70C02 / BRLETAN70C02 | 7.0 mm |
| ETAN75C02 / BRLETAN75C02 | 7.5 mm |
| ETAN80C02 / BRLETAN80C02 | 8.0 mm |
| ETAN85C02 / BRLETAN85C02 | 8.5 mm (this product) |
| ETAN90C02 / BRLETAN90C02 | 9.0 mm |
4. Equivalences and Cross-References
The manufacturer’s reference ETAN85C02 matches the in-house code of the BRLETAN85C02 range (distributor SKU Cahnos); both correspond to the same 8.5 mm oronasal cuffed endotracheal tube. There is no manufacturer-validated equivalence table cross-referencing this reference with official codes from other brands: oral cuffed endotracheal tubes from market lines (such as Teleflex/Rüsch, Medtronic/Shiley, ICU Medical/Portex or Intersurgical) belong to the same functional category and general clinical indication, but are not interchangeable 1:1. Before any substitution, the internal diameter, material type, presence of a Murphy eye, cuff type, length and applicable standards must be verified specification by specification. Consult the technical-commercial team at Cahnos for the approval of references and alternatives in tenders.
5. Selection tips and variants of interest
The 8.5 mm size is intended for large adult patients or wide-calibre airways; as a general clinical practice guideline, tubes of 7.0 to 10.0 mm are used in adults depending on build and airway assessment, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol. The cuffed configuration is the appropriate option for prolonged positive-pressure ventilation, general anaesthesia and situations requiring an airtight seal and prevention of aspiration. After intubation, inflate the cuff via the pilot balloon and maintain a sealing pressure within the usual clinical range (ideally 20–30 cmH₂O; check the service protocol) to minimise damage to the tracheal mucosa. To complete the equipment for your service, the Cahnos catalogue offers the full range of sizes (3.5 to 9.0 mm) and intubation variants (compatible stylets, laryngoscopes and suction catheters). Single-use product: do not re-sterilise or reuse. For large orders you can request a quote: contact the technical-commercial department at Cahnos for samples, volume conditions and hospital supply lead times.