Absorbable Multifilament Suture PGLA Polyglactin 910 Prime – 5/8 Circle Cylindrical Needle Taperpoint Conical Tip FR 40 mm – USP 0 Gauge (Metric 3.5) – Violet Fluted Thread 70 cm – Ref. P1L18FR4010 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable suture PREMISUT Prime of Polyglactin 910 (PGLA) multifilament braided, with 5/8 circle needle, cylindrical body and Taperpoint conical tip of 40 mm (FR 40), USP 0 gauge (metric 3.5) and violet fluted thread of 70 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L18FR4010, presentation in box of 12 units with minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18FR4010

Description

1. Commercial Introduction

The absorbable multifilament suture of polyglactin 910 (PGLA) from the Premisut Prime range is the reference choice in the operating theatre for hospitals, ophthalmology clinics, private operating theatres and purchasing centres looking for a high-performance synthetic thread with an excellent value-for-money ratio. This reference P1L18FR4010 combines a 5/8 circle needle with cylindrical body and Taperpoint conical tip of 40 mm (FR 40), USP 0 gauge (metric 3.5) and violet fluted thread of 70 cm. Each unit is supplied sterile and ready to use, with the guarantee of professional distribution from Cahnos and the traceability required by your healthcare centre.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a multifilament braided structure with a fluted finish. This configuration provides a regular surface that favours thread sliding through tissue, very smooth handling, low memory and a firm, secure knot tie, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues requiring wound support during the critical 2 to 4 weeks of healing. The 5/8 circle needle with Taperpoint conical tip penetrates by separating fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery and for approximating friable tissues. The violet colour guarantees optimal visibility of the thread on the surgical field. Sterile single-use product, not for re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference P1L18FR4010

Characteristic Specification
Reference (SKU) P1L18FR4010
Range / Quality Premisut, Prime quality
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 0 (metric 3.5)
Thread colour Fluted violet (colourless version available in the family)
Thread length 70 cm
Needle shape 5/8 circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size 40 mm (FR 40 Prime)
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (EO), single-use, not re-sterilisable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Total absorption 56-72 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate. Price per box of 12 units.

3.3. Presentation and ordering conditions

Value Value
Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widespread synthetic absorbable materials on the European market. This reference is clinically comparable, by composition, absorption profile and tensile retention, to braided multifilament sutures from the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Absorbable braided polyglactin 910 range
SMI Surgicryl (braided polyglactin 910, violet)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Range of polyglactin 910 with 5/8 circle cylindrical needles with conical tip

Within the Cahnos catalogue, its direct equivalent in structure and geometry in standard quality is reference 1L18FR4010 (same FR 40 mm needle, USP 0 gauge and violet 70 cm thread). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most appropriate suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during a 2 to 4 week healing period. The 5/8 circle needle with Taperpoint conical tip is especially recommended in delicate tissues where atraumatic penetration is prioritised; for fibrous structures or the sclera, cutting or trocar tips are recommended.

Reference Variant
P1L18FR4010 PGLA Prime USP 0, 5/8 cylindrical needle FR 40 mm, violet, 70 cm (current product)
1L18FR4010 PGLA standard quality, same 70 cm configuration
P1L18FR4020 PGLA Prime USP 2/0, same FR 40 mm needle, violet, 70 cm (smaller gauge)
P1L18HR4010 PGLA Prime USP 0, 1/2 circle needle HR 40 mm, violet, 70 cm (different needle curve)
P1L18HS4010 PGLA Prime USP 0, reverse cutting triangular needle HS 40 mm, violet, 70 cm (firm tissues)
P1L18JR3020 PGLA Prime USP 2/0, J-shaped needle JR 30 mm, violet, 70 cm
AMP118FR4010 PGA Prime USP 0, 5/8 FR 40 mm needle, violet, 70 cm (absorption 60 to 90 days)

All references are supplied in a box of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. If you need a longer strength retention (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial brands, contact our technical-commercial team.

Additional information

Reference

P1L18FR4010

Quality range

Premisut Prime

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 0 (metric 3.5)

Thread colour

Violet grooved

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

40 mm (FR 40 Prime)

Sterilisation

Ethylene oxide (EO), single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

FR 40

Usp

0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

5/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)