Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament suture of Polyglactin 910 (PGLA) from the PREMISUT range, reference 1L12FR2720, designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a 5/8 circle needle with a cylindrical body and conical point (taperpoint) of 27 mm (FR 27), USP 2/0 gauge and a 75 cm violet fluted braided thread: maximum visibility on the surgical field and precision in delicate tissues.
It is the reference choice for hospitals, private clinics, ophthalmologists and purchasing centres looking for a high-performance synthetic absorbable thread with an excellent quality-price ratio. Each unit is supplied sterile, ready to use and single-use, in a box of 12 units with a minimum order of 30 boxes, ensuring the continuity and traceability of supply for your healthcare centre.
2. Technical Explanation
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, structured as a braided multifilament with a fluted finish. This configuration provides great flexibility, low memory and a low friction coefficient, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity, maintaining the apposition of the wound edges during the critical phase of healing (2 to 4 weeks), while the tissue recovers its own strength.
The 5/8 circle needle with cylindrical body and conical point (taperpoint) penetrates by separating the fibres without a cutting effect, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery and for the approximation of friable tissues. The violet colour ensures optimal visibility of the thread on the surgical field throughout the procedure. The product is supplied sterile by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 1L12FR2720
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L12FR2720 |
| Range / Quality | PREMISUT – Standard quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet (colourless version available in the family) |
| Thread length | 75 cm |
| Needle shape | 5/8 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 27 mm (FR 27) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56 – 72 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days, by hydrolysis |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
3.4. Presentation and ordering conditions
| Value | Value |
|---|---|
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This braided suture with medium absorption is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines of the international market:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910, violet) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | DemeCRYL (polyglactin 910) |
| Dolphin Sutures | Petcryl 910 (polyglactin 910) |
| CPT Sutures | CARESORB (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Multifilament PGLA with 5/8 circular cylindrical needle (FR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (FR 27 mm needle, USP 2/0 gauge, 75 cm violet thread) is the higher quality version P1L12FR2720 (Prime range). The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) offers an excellent balance between strength and delicacy: it is suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ophthalmic surgery procedures, with predictable absorption during healing of 2 to 4 weeks. The 5/8 circle needle with conical point (taperpoint) of 27 mm is especially recommended in delicate tissues where a cutting effect is to be avoided; for fibrous structures or the sclera, cutting or trocar points are recommended. Check the needle radius (FR 27, FR 36 or FR 40 mm) according to the depth and surgical area to be treated; for greater tensile strength consider USP 0 gauges or higher, and if a longer strength retention is required (180-210 days), the polydioxanone (PDO) family is the recommended alternative.
| Reference | Variant |
|---|---|
| P1L12FR2720 | PGLA Prime USP 2/0, FR 27 mm needle, violet, 75 cm (premium range) |
| 1L12FR2730 | PGLA USP 3/0, needle FR 27 mm, violet, 75 cm (finer gauge) |
| 1L18FR2710 | PGLA USP 0, needle FR 27 mm, violet, 70 cm (larger gauge) |
| 1L18FR2720-2 | PGLA USP 2/0, double FR 27 mm needle, violet, 70 cm (reduced access) |
| 1L18FR3601 | PGLA USP 1, FR 36 mm needle, violet, 70 cm (larger needle radius) |
| 1L18FR4020 | PGLA USP 2/0, FR 40 mm needle, violet, 70 cm (larger needle radius) |
| AM112FR2720 | PGA USP 2/0, needle FR 27 mm, violet, 75 cm (absorption 60-90 days) |
| 1L12HR2620 | PGLA USP 2/0, 1/2 circle needle HR 26 mm, violet, 75 cm |
As it is a sterile single-use product, always check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. All references in the range are supplied in boxes of 12 units with a minimum order of 30 boxes, with scheduled deliveries for hospitals, clinics and purchasing centres. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.