Description
1. Commercial Introduction
The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L18FR4010 from the Premisut range, is the reference surgical closure solution for the professional who demands a flexible, resistant thread with fully predictable absorption in the operating theatre. Its ⅝ circle needle with cylindrical body and Taperpoint conical point of 40 mm (FR 40) separates tissue fibres without cutting them, minimising trauma and being especially suitable for the approximation of soft tissues, ligatures and ophthalmic surgery procedures. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B procurement of hospitals, ophthalmic clinics, private operating theatres and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, which guarantees the continuous and traceable supply of your healthcare centre.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that favours the passage of the thread through the tissue, very smooth handling, low memory and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support during the critical 2 to 4 weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ⅝ circle needle with conical point (Taperpoint) penetrates by separating the fibres without cutting them, and the violet colouration of the thread guarantees optimal visibility on the surgical field. The product is supplied sterile by ethylene oxide (EO), single-use and without the possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 1L18FR4010
| Characteristic | Specification |
| Reference (SKU) | 1L18FR4010 |
| Range / Quality | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (also available colourless) |
| Thread length | 70 cm |
| Needle shape | ⅝ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | 40 mm (FR 40) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Presentation and ordering conditions
| Value | Value |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most widely used synthetic absorbable materials in the European market. This reference is clinically comparable, in terms of composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Absorbable braided polyglactin 910 range |
| SMI | Surgicryl (braided polyglactin 910, violet) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ⅝ circle cylindrical needles with conical tip |
Within the Cahnos catalogue, its direct equivalent in structure and geometry within the Prime range is reference P1L18FR4010 (same FR 40 mm needle, USP 0 gauge and 70 cm violet thread, superior quality). The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ophthalmic surgery procedures, with an excellent balance between initial resistance and predictable absorption during a 2 to 4 week healing period. The ⅝ circle needle with conical point (Taperpoint) is especially recommended in ophthalmic surgery and delicate tissues, where atraumatic penetration is prioritised; for fibrous structures or the sclera, cutting or trocar points are recommended.
| Reference | Variant |
| 1L18FR4010 | PGLA USP 0, 5/8 cylindrical needle FR 40 mm, violet, 70 cm (current product) |
| P1L18FR4010 | PGLA Prime quality, same 70 cm configuration (superior range) |
| 1L18FR4020 | PGLA USP 2/0, same FR 40 mm needle, violet, 70 cm (smaller gauge) |
| 1L18HR4010 | PGLA USP 0, ½ circle needle HR 40 mm with conical point, violet, 70 cm (different needle curve) |
| 1L18HS4010 | PGLA USP 0, HS 40 mm reverse cutting triangular needle, violet, 70 cm (firm tissues) |
| AM118FR4010 | PGA USP 0, 5/8 FR 40 mm needle, violet, 70 cm (absorption 60 to 90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. If you need a longer force retention (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.