Description
Product presentation
The absorbable multifilament suture PREMISUT made of polyglactin 910 (PGLA) in Prime Fine quality, reference P1L21DS1940FN, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, minor surgery practices and purchasing centres. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and high knot security in tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circle needle with a 19 mm triangular reverse cutting point (DS19) in the Fine version ensures firm, controlled penetration even in fine, less compliant tissues, while the 45 cm colourless, smooth thread offers maximum aesthetic discretion on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and non-reesterilizable, offering excellent value for money for the continuous supply of your facility.
Technical description
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a smooth finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 4/0 (metric 1.5).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with a triangular reverse cutting point penetrates firm and fibrous tissues with controlled trauma, avoiding tears, which is why it is especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The colourless colour of the thread minimises its visibility, an advantage appreciated in aesthetic and reconstructive procedures. The product is supplied sterile by ethylene oxide and must not be re-sterilised.
Technical specifications
General characteristics of reference P1L21DS1940FN
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (Prime quality, premium range) |
| Reference (SKU) | P1L21DS1940FN |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament, non-ribbed |
| Gauge | USP 4/0 (metric 1.5) |
| Thread colour | Colourless |
| Thread length | 45 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS19 (19 mm) Fine Prime |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56 – 72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units; minimum order of 30 boxes for institutional supply.
Gauge equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm (indicative according to Pharmacopoeia) |
Equivalences and cross-references
Polyglactin 910 is the most widely used medium-duration absorbable multifilament in the surgical market. This PREMISUT Prime suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (braided coated polyglactin 910, violet or colourless) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Braided multifilament polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in violet with the same configuration (triangular DS19 mm Fine needle, USP 4/0, 45 cm) is reference P1L11DS1940FN, and the colourless 70 cm variant corresponds to P1L28DS1940FN, while the violet 70 cm version is P1L18DS1940FN. In the precision family with square body, P1L21XDS1940 stands out. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 4/0 (metric 1.5) is indicated for fine and delicate tissues: skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The triangular reverse cutting point needle (DS19 Fine) is especially recommended for firm or difficult-to-penetrate tissues, where the needle passage must be clean and without tears.
| Reference | Variant |
|---|---|
| P1L21DS1940FN | PGLA Prime, DS19 mm Fine needle, USP 4/0, colourless, 45 cm (current product) |
| P1L11DS1940FN | PGLA Prime, DS19 mm Fine needle, USP 4/0, violet, 45 cm (greater visibility) |
| P1L28DS1940FN | PGLA Prime, DS19 mm Fine needle, USP 4/0, colourless, 70 cm (greater length) |
| P1L18DS1940FN | PGLA Prime, DS19 mm Fine needle, USP 4/0, violet, 70 cm |
| P1L22DS1940 | PGLA Prime, standard DS19 mm needle, USP 4/0, colourless, 75 cm |
| P1L21DS1950 | PGLA Prime, DS19 mm needle, USP 5/0, colourless, 45 cm (smaller gauge) |
| P1L21XDS1940 | PGLA Prime, XDS19 precision needle with square body, USP 4/0, colourless, 45 cm |
| AMP121DS1940FN | PGA (polyglycolic acid), DS19 mm Fine needle, USP 4/0, colourless, 45 cm (absorption 60 to 90 days) |
For maximum aesthetic discretion, this colourless version is the most suitable; if you require greater visibility in the field, choose the violet version. If your protocol requires longer tensile support (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos; if, on the other hand, you seek faster absorption, consult the Rapid range of the same family. All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.




Reviews