Description
1. Product Presentation
The absorbable multifilament suture PREMISUT of polyglactin 910 (PGLA) in Prime quality is the trusted solution for professionals seeking a high-performance surgical thread with predictable behaviour and excellent handling in every procedure. Its ⅜ circle needle with a 36 mm (DS36) reverse cutting triangular point ensures clean, controlled penetration, even in firm tissues, while the 75 cm grooved violet thread offers optimal visibility over the surgical field and smooth sliding.
Designed for B2B supply to hospitals, ophthalmic clinics, distributors and purchasing centres, it is presented in a box of 12 units with a minimum order of 30 boxes, ensuring continuous supply with an excellent price-quality ratio.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured in a braided multifilament structure with a grooved finish. This architecture provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in medium sizes such as USP 0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing. The ⅜ circular needle with reverse cutting triangular point (reverse cutting) penetrates firm and dense tissues with controlled trauma, avoiding tears. The product is supplied sterile by ethylene oxide, is single-use and is not re-sterilisable.
3. Technical Specifications
3.1. General characteristics of reference P1L12DS3610
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (Prime quality) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Colour | Violet |
| Needle shape | ⅜ circle |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | DS 36 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12DS3610 |
3.2. Tensile strength retention profile
| Time | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 (PGLA) is the most widely used medium-duration absorbable multifilament in the surgical market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Range of polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same DS 36 mm configuration in standard quality is reference 1L12DS3610. In the polyglycolic acid (PGA) family, reference AMP112DS3610 stands out (same DS 36 mm triangular needle, USP 0, violet, 75 cm), recommended when an absorption profile of 60 to 90 days is preferred.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary size according to the anatomical area. USP 0 size (metric 3.5) offers an ideal balance between initial strength and handling for soft tissues, ligatures and microsurgery. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis).
| Reference | Variant |
|---|---|
| P1L12DS3610 | PGLA Prime USP 0, ⅜ triangular needle DS 36 mm, violet, 75 cm (current product) |
| P1L12DS3620 | PGLA Prime USP 2/0, same DS 36 mm needle (fine size) |
| P1L12DS3601 | PGLA Prime USP 1, same DS 36 mm needle (larger size) |
| P1L12DS3602 | PGLA Prime USP 2, same DS 36 mm needle (deep planes and high tension) |
| P1L12DS3010 | PGLA Prime USP 0, ⅜ triangular needle DS 30 mm (shorter needle) |
| 1L12DS3610 | PGLA standard quality, same DS 36 mm configuration, USP 0, violet, 75 cm |
| AMP112DS3610 | PGA Prime USP 0, DS 36 mm needle (absorption profile of 60 to 90 days) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.