Description
The absorbable suture PREMISUT of Polyglactin 910 (PGLA) in Prime quality, reference P1L18DS2440, is the professional reference solution for B2B supply of operating theatres, ophthalmology clinics, minor surgery practices and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security for the approximation of soft tissues, ligatures and ophthalmic surgery procedures. Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24) ensures firm, controlled penetration in dense, non-compliant tissues, while the 70 cm violet braided fluted thread provides smooth glide during suturing and optimal visibility on the surgical field. It is a synthetic absorbable medical device, sterile, single-use and non-resterilisable, with an excellent value-for-money ratio for the continuous supply of your facility.
Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates thread passage through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 4/0. Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, non-compliant tissues with controlled trauma, avoiding tears, which is why it is especially indicated in sclera and ophthalmic tissues, as well as for tissue approximation and ligatures. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide and must not be resterilised.
Technical specifications
3.1. General characteristics of reference P1L18DS2440
| Parameter | Specification |
| Brand / Range | PREMISUT (Prime quality, premium range) |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 4/0 |
| Thread colour | Violet (also available undyed in the range) |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS 24 mm (Prime) |
| Thread length | 70 cm |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Reference (SKU) | P1L18DS2440 |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 4/0 | 1.5 | 0.15 – 0.199 mm (indicative, according to Pharmacopoeia) |
Equivalences and cross-references
Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of braided polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910, violet colour) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | Braided multifilament polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the standard range with the same configuration (triangular needle DS 24 mm, USP 4/0, violet and 70 cm) is reference 1L18DS2440. The Prime variant in colourless is P1L28DS2440, and in the polyglycolic acid (PGA) family with longer absorption (60-90 days) is AMP118DS2440. The equivalences indicated are for guidance; for formal substitution of references, consult our technical-commercial department.
Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 4/0 gauge is indicated for fine, delicate tissues: skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The reverse cutting triangular point needle (DS 24) is especially recommended in firm, non-compliant tissues, where needle passage must be clean and without tearing.
| Reference | Variant |
| P1L18DS2440 | PGLA Prime USP 4/0, triangular needle DS 24 mm, violet, 70 cm (current product) |
| P1L28DS2440 | PGLA Prime USP 4/0, same needle DS 24 mm, colourless, 70 cm (maximum discretion in the field) |
| 1L18DS2440 | PGLA standard USP 4/0, same configuration DS 24 mm, violet, 70 cm (standard range) |
| P1L18DS1940FN | PGLA Prime USP 4/0, triangular needle DS 19 mm Fine, violet, 70 cm (shorter needle) |
| P1L12DS2430 | PGLA Prime USP 3/0, same needle DS 24 mm, violet, 75 cm (finer gauge) |
| P1L12DS2420 | PGLA Prime USP 2/0, same needle DS 24 mm, violet, 75 cm (larger gauge) |
| AMP118DS2440 | PGA Prime USP 4/0, triangular needle DS 24 mm, violet, 70 cm (absorption 60-90 days) |
If you require longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.





Reviews
There are no reviews yet.