We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 PREMISUT Prime | Needle 3/8 Circle Triangular Point Reverse Cutting DS 24 mm | USP 4/0 | Violet Fluted Thread 70 cm | Ref. P1L18DS2440 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable suture PREMISUT of Polyglactin 910 (PGLA) in Prime quality, with a ⅜ circle reverse cutting triangular point needle of 24 mm (DS 24), USP 4/0 gauge and 70 cm violet fluted thread. Predictable absorption by hydrolysis in 56-72 days, with strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and optimal knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L18DS2440, presentation in box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18DS2440

Description

The absorbable suture PREMISUT of Polyglactin 910 (PGLA) in Prime quality, reference P1L18DS2440, is the professional reference solution for B2B supply of operating theatres, ophthalmology clinics, minor surgery practices and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security for the approximation of soft tissues, ligatures and ophthalmic surgery procedures. Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24) ensures firm, controlled penetration in dense, non-compliant tissues, while the 70 cm violet braided fluted thread provides smooth glide during suturing and optimal visibility on the surgical field. It is a synthetic absorbable medical device, sterile, single-use and non-resterilisable, with an excellent value-for-money ratio for the continuous supply of your facility.

Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates thread passage through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 4/0. Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, non-compliant tissues with controlled trauma, avoiding tears, which is why it is especially indicated in sclera and ophthalmic tissues, as well as for tissue approximation and ligatures. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide and must not be resterilised.

Technical specifications

3.1. General characteristics of reference P1L18DS2440

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 4/0
Thread colour Violet (also available undyed in the range)
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS 24 mm (Prime)
Thread length 70 cm
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Reference (SKU) P1L18DS2440

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

3.3. Size equivalence

USP size Metric size Approximate diameter
4/0 1.5 0.15 – 0.199 mm (indicative, according to Pharmacopoeia)

Equivalences and cross-references

Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of braided polyglactin 910:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910, violet colour)
Assut Assucryl 910 (polyglactin 910)
Laboratorio Aragó (Premisut range) Braided multifilament polyglactin 910 with ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent in the standard range with the same configuration (triangular needle DS 24 mm, USP 4/0, violet and 70 cm) is reference 1L18DS2440. The Prime variant in colourless is P1L28DS2440, and in the polyglycolic acid (PGA) family with longer absorption (60-90 days) is AMP118DS2440. The equivalences indicated are for guidance; for formal substitution of references, consult our technical-commercial department.

Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 4/0 gauge is indicated for fine, delicate tissues: skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The reverse cutting triangular point needle (DS 24) is especially recommended in firm, non-compliant tissues, where needle passage must be clean and without tearing.

Reference Variant
P1L18DS2440 PGLA Prime USP 4/0, triangular needle DS 24 mm, violet, 70 cm (current product)
P1L28DS2440 PGLA Prime USP 4/0, same needle DS 24 mm, colourless, 70 cm (maximum discretion in the field)
1L18DS2440 PGLA standard USP 4/0, same configuration DS 24 mm, violet, 70 cm (standard range)
P1L18DS1940FN PGLA Prime USP 4/0, triangular needle DS 19 mm Fine, violet, 70 cm (shorter needle)
P1L12DS2430 PGLA Prime USP 3/0, same needle DS 24 mm, violet, 75 cm (finer gauge)
P1L12DS2420 PGLA Prime USP 2/0, same needle DS 24 mm, violet, 75 cm (larger gauge)
AMP118DS2440 PGA Prime USP 4/0, triangular needle DS 24 mm, violet, 70 cm (absorption 60-90 days)

If you require longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Quality

Prime (Premisut range)

Needle tip

Triangular with reverse cutting (inverted triangular)

Strength retention

75 % (2 weeks), 50 % (3 weeks), 30 % (4 weeks)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 24

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 PREMISUT Prime | Needle 3/8 Circle Triangular Point Reverse Cutting DS 24 mm | USP 4/0 | Violet Fluted Thread 70 cm | Ref. P1L18DS2440 – Box of 12 units”

Your email address will not be published. Required fields are marked *