Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLA Polyglactin 910 Ref. P1L12DS2620, from the PREMISUT Prime quality range, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security. Its ⅜ circle needle with 26 mm reverse cutting triangular point (DS26) allows firm, controlled penetration in dense tissues, particularly indicated in ophthalmic surgery, ligatures and tissue approximation.
Available in B2B presentation in a box of 12 units, this reference offers excellent value for money for hospitals, ophthalmic clinics, purchasing groups and distributors of surgical supplies.
2. Technical explanation
It is a braided (multifilament) synthetic absorbable suture made from polyglactin 910 (PGLA), a copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration facilitates the passage of the thread through tissue, provides smooth glide and ensures firm, secure knot tying, even in fine diameter gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The 26 mm ⅜ circle needle with reverse cutting triangular point (inverted triangle) penetrates firm, dense tissues with controlled trauma, avoiding tears. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (Prime quality) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Colour | Violet (also available colourless in the range) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular) |
| Needle size | DS26 (26 mm) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Reference (SKU) | P1L12DS2620 |
Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot security, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 (PGLA) is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT suture is equivalent in composition and behaviour to the main commercial polyglactin 910 ranges:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Range of polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the standard range with the same DS 26 mm needle configuration, USP 2/0 gauge, violet and 75 cm is reference 1L12DS2620. It shares a family with the other gauges in the DS26 series: 1L12DS2630 (USP 3/0), P1L12DS2630 (Prime USP 3/0) and P1L12RDS2630.2 (Prime USP 3/0, double thread 2×75 cm).
5. Selection tips and variants of interest
To choose the most suitable suture, take into account the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 2/0 gauge (metric 3) offers an ideal balance between initial strength and manageability for fine tissues, ligatures and ophthalmic surgery. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing.
| Reference | Variant |
|---|---|
| P1L12DS2620 | PGLA Prime USP 2/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (current product) |
| 1L12DS2620 | PGLA standard USP 2/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (standard range) |
| 1L12DS2630 | Standard PGLA USP 3/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (smaller calibre) |
| P1L12DS2630 | PGLA Prime USP 3/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (finer gauge, Prime) |
| P1L12RDS2630.2 | PGLA Prime USP 3/0, DS 26 mm needle, violet, 2 threads of 75 cm |
| P1L12DS2420 | PGLA Prime USP 2/0, ⅜ triangular needle DS 24 mm, violet, 75 cm (shorter needle) |
| 1L12DS2420 | Standard PGLA USP 2/0, ⅜ triangular needle DS 24 mm, violet, 75 cm (shorter needle) |
All references are supplied in a box of 12 units. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.