We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Suture, Prime Quality | Needle 3/8 Circle Triangular Point Reverse Cutting DS 24 mm | USP 2/0 (Metric 3) | Colourless Grooved Thread 75 cm | Ref. P1L22DS2420 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable suture PREMISUT PGLA Prime of Polyglactin 910 (PGLA), a copolymer of 90% glycolide and 10% L-lactide, in sterile single-use presentation. Needle ⅜ circle DS 24 mm with reverse cutting triangular point, colourless braided grooved multifilament thread of 75 cm and USP 2/0 (metric 3) gauge. Predictable absorption by hydrolysis in 56-72 days with strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L22DS2420, box of 12 units with a minimum order of 30 boxes for institutional B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L22DS2420

Description

1. Commercial Introduction

The multifilament absorbable suture of Polyglactin 910 (PGLA) from the PREMISUT range in Prime quality, reference P1L22DS2420, is the reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and distributors. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security for the approximation of soft tissues, ligatures and ophthalmic surgery.

Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24 Prime) ensures firm, controlled penetration even in dense, non-compliant tissues, while the 75 cm colourless grooved thread offers smooth passage during suturing and maximum discretion on the surgical field. It is a synthetic absorbable medical device, sterilised by ethylene oxide, single-use and non-reesterilizable, with an excellent cost-performance ratio for the continuous supply of your centre.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing (75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks), while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, fibrous tissue with controlled trauma, avoiding tearing, which is why it is particularly indicated for the sclera and ophthalmic tissues, tissue approximation and ligatures. The product is supplied sterile by ethylene oxide and must not be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L22DS2420

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Material Polyglactin 910 (PGLA), copolymer of 90% glycolide and 10% L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 2/0 (metric 3)
Thread colour Colourless (also available in violet in the range)
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (inverted triangular / reverse cutting)
Needle size DS 24 mm (Prime)
Thread length 75 cm
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation By ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L22DS2420

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75%
3 weeks 50%
4 weeks 30%
Complete absorption 56-72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Size equivalence

USP size Metric size
2/0 3

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of braided polyglactin 910:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided coated polyglactin 910, violet / colourless)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
Laboratorio Aragó (Premisut range) Braided multifilament polyglactin 910 with ⅜ circle needles (DS series)

Within the Cahnos catalogue, in the same needle and material configuration but with a longer absorption profile (60-90 days), there is the reference from the PGA family AMP122DS2420 (triangular DS 24 mm needle, USP 2/0, colourless, 75 cm). In Prime PGLA quality, the violet colour variant is P1L12DS2420 and the gauge variants of the same needle are P1L22DS2430 (USP 3/0) and P1L22DS2410 (USP 0). For rapid absorption (40-45 days) the PGLAR range AMP2L22DS2420 is available.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 (metric 3) is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The reverse cutting triangular point needle (DS 24) is especially recommended for firm, non-compliant tissues, where the needle passage must be clean and without tearing.

Reference Variant
P1L22DS2420 PGLA Prime USP 2/0, ⅜ triangular DS 24 mm needle, colourless, 75 cm (current product)
P1L12DS2420 PGLA Prime USP 2/0, same DS 24 mm needle, violet, 75 cm (greater visibility in the field)
P1L22DS2430 PGLA Prime USP 3/0, same DS 24 mm needle (finer gauge)
P1L22HS2220 PGLA Prime USP 2/0, ½ circle triangular HS 22 mm needle, colourless, 75 cm (½ circle ophthalmic format)
AMP122DS2420 PGA Prime USP 2/0, triangular DS 24 mm needle, colourless, 75 cm (absorption 60-90 days)
AMP2L22DS2420 PGLAR Rapid Polyglactin 910 DS 24 mm, USP 2/0, colourless, 75 cm (absorption 40-45 days)

In the Cahnos catalogue you will find other thread lengths (45, 70 and 75 cm), gauges from 4/0 to 0, double-needle versions, other needle geometries (HS 22 mm, precision XDS and cylindrical types) and the PGLAR rapid absorption range. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

Quality

Prime (PREMISUT)

USP size

2/0 (metric 3)

Needle tip

Reverse cutting triangular (reverse cutting)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 24

Usp

2/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Suture, Prime Quality | Needle 3/8 Circle Triangular Point Reverse Cutting DS 24 mm | USP 2/0 (Metric 3) | Colourless Grooved Thread 75 cm | Ref. P1L22DS2420 – Box of 12 units”

Your email address will not be published. Required fields are marked *