The absorbable multifilament Polyglactin 910 (PGLA) suture reference 1L12DS4001 is the technical reference solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and high knot security in tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circular needle with reverse cutting triangular point of 40 mm (DS40) offers firm and controlled penetration, ideal for firm and consistent tissues, while the violet braided thread of 75 cm ensures optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for the B2B supply of operating theatres, ophthalmic clinics, purchasing groups and distributors. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ensuring the continuous supply of your healthcare centre.
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in larger diameter calibres such as USP 1.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ⅜ circle needle with reverse cutting triangular point (inverted triangular or ‘reverse cutting’) of 40 mm penetrates firm and dense tissues with controlled trauma, avoiding tears, being especially indicated in tissue approximation, ligatures and ophthalmic and general surgery procedures. The product is supplied sterile by ethylene oxide, single-use and without the possibility of re-sterilisation.
Technical specifications
General characteristics of reference 1L12DS4001
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Colour | Violet (also available colourless) |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (reverse cutting) |
| Needle size | DS 40 mm |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | 1L12DS4001 |
Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
Equivalences and cross-references
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Absorbable braided polyglactin 910 range |
| Laboratory Aragó | Range of polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglactin 910 family with Prime quality is reference P1L12DS4001 (same triangular DS 40 mm needle, USP 1, violet, 75 cm), ideal when seeking the upper range. In the polyglycolic acid (PGA) family, AM112DS4001 stands out (same triangular DS 40 mm needle, USP 1, violet, 75 cm), recommended when a 60 to 90 day absorption profile is preferred.
Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary calibre according to the anatomical area. USP 1 calibre (metric 4) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. Polyglactin 910 offers an excellent balance between initial resistance and predictable absorption for soft tissues with healing of 2 to 4 weeks. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing.
| Reference | Variant |
| 1L12DS4001 | PGLA USP 1, ⅜ triangular DS 40 mm needle, violet, 75 cm (current product) |
| 1L12DS4010 | PGLA USP 0, ⅜ triangular DS 40 mm needle, violet, 75 cm (smaller calibre, moderate tension) |
| 1L12DS3601 | PGLA USP 1, ⅜ triangular DS 36 mm needle, violet, 75 cm (shorter needle) |
| 1L12DS3010 | PGLA USP 0, ⅜ triangular DS 30 mm needle, violet, 75 cm (even shorter needle) |
| 1L18HS4001 | PGLA USP 1, ½ circle triangular HS 40 mm needle, violet, 70 cm (another needle curve) |
| 1L13HS4001 | PGLA USP 1, ½ circle triangular HS 40 mm needle, violet, 90 cm (longer thread length) |
| AM112DS4010 | PGA USP 0, ⅜ triangular needle DS 40 mm, violet, 75 cm (absorption from 60 to 90 days) |
If you need longer force retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.