We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Polyglactin 910 Prime Suture, ⅜ Circle Needle Precision Reverse Cutting Triangular Point XDS19 mm, USP 3/0, Undyed, 45 cm (Ref. P1L21XDS1930)

Original price was: 70,00 €.Current price is: 50,00 €.

Absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, with a ⅜ circular needle with precision reverse cutting triangular point and square body of 19 mm (XDS19). Gauge USP 3/0 (metric 2, diameter 0.20–0.249 mm), undyed non-grooved thread of 45 cm. Absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterilised by ethylene oxide, it offers minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units. Reference P1L21XDS1930.

Se fabrica bajo pedido: el fabricante exige un mínimo de 8 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L21XDS1930

Description

1. Commercial Introduction

The Absorbable Multifilament PGLA Polyglactin 910 Prime Suture is the trusted choice for the professional seeking an optimal balance between handling, knot security and controlled absorption. Presented with a ⅜ circle needle with precision reverse cutting triangular point and square body of 19 mm (XDS19), it is designed for procedures requiring clean penetration and minimal tissue resistance, in both tissue approximation and ligation and ophthalmic surgery.

Manufactured under Prime quality standards and available for wholesale distribution, this reference offers predictable performance and an excellent value for money for clinics, hospitals and purchasing centres.

2. Technical Explanation

It is a synthetic absorbable braided (multifilament) suture made of polyglactin 910, a copolymer composed of 90% glycolide and 10% L-lactide. Its absorption mechanism is hydrolysis, a predictable process that does not depend on tissue enzymes and guarantees a constant mass loss between 56 and 72 days.

The undyed, non-grooved thread offers a regular surface that facilitates sliding through tissue and firm knot anchorage. The XDS19 mm needle, with reverse cutting triangular point and square body, is ideal for resistant tissues such as skin and mucous membranes, providing controlled penetration with minimal tissue bed injury.

3. Technical Specifications

3.1. General characteristics

Characteristic Detail
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Structure Braided multifilament, non-grooved
Thread colour Colourless (violet on demand)
USP size 3/0 (metric 2)
Thread length 45 cm
Needle shape ⅜ circle
Needle tip Precision reverse cutting triangular
Needle body Square
Needle size XDS 19 mm
Quality Prime
Sterilisation Ethylene oxide (EtO)
Presentation Box of 12 units
Reference P1L21XDS1930

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 56 – 72 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 30 %
Tissue reaction Minimal

3.3. Size equivalence

USP size Approximate diameter Metric
3/0 0.20 – 0.249 mm 2

Price per box of 12 units. See B2B terms for orders in multiples.

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used absorbable multifilament material in the surgical market and its clinical behaviour is comparable to that of braided polyglactin 910 sutures from the leading international manufacturers (reference lines such as Ethicon’s polyglactin 910, Vicryl). In the Cahnos catalogue, the warehouse version of this same presentation corresponds to reference AMP1L21XDS1930.

Notable references of the same material with other configurations include: P1L21XDS1940 (same XDS19 needle in gauge 4/0), P1L21XDS1950 (same XDS19 needle in gauge 5/0) and P1L21DS1930 (3/8 needle with DS19 reverse cutting triangular point in gauge 3/0). For faster reabsorption applications, the Rapid lines of the same family are available, and for other compositions of the same format, the PGA range or the PGCL caprolactone range may be considered.

5. Selection tips and variants of interest

USP gauge 3/0 (metric 2) combines a fine diameter with excellent initial strength, making it a very versatile size for tissue approximation, ligatures, skin in areas of moderate tension, mucous membranes and ophthalmic surgery. The ⅜ circle needle with precision reverse cutting point and square body is especially recommended for firm or difficult-to-penetrate tissues, where control and high puncture capacity are required without tearing.

If your protocol requires a finer gauge, consider the 4/0 and 5/0 versions of the same XDS19 needle; if you need longer tensile support, consider the absorbable monofilament polydioxanone lines; if, on the other hand, you are looking for faster absorption, consult the Rapid polyglactin 910 range. For high visibility conditions in the field, the same reference is available in violet on request. Contact our technical-commercial team to optimise your order by box and take advantage of special B2B conditions.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament, non-grooved

Thread colour

Colourless (violet on request)

Metric

2

Thread diameter

0.20 – 0.249 mm

Needle tip

Precision reverse cutting triangular

Needle body

Square

Sterilisation

Ethylene oxide (EtO)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Medida de aguja

XDS 19

Usp

3/0

Color

Colourless, Violet

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Polyglactin 910 Prime Suture, ⅜ Circle Needle Precision Reverse Cutting Triangular Point XDS19 mm, USP 3/0, Undyed, 45 cm (Ref. P1L21XDS1930)”

Your email address will not be published. Required fields are marked *