We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Poliglactin 910 Prime · 3/8 Circle Needle Triangular Point Conventional Precision Cutting XNS16 mm Square Body · USP 5/0 · Colourless · 45 cm · Box of 12 units (Ref. P1L21XNS1650)

Original price was: 70,00 €.Current price is: 50,00 €.

Absorbable multifilament Poliglactin 910 (PGLA) suture from the Prime (PREMISUT) range, with a ⅜ circle needle, triangular point in conventional precision cutting and square body of 16 mm (XNS16). USP 5/0 gauge, colourless non-grooved thread of 45 cm, with predictable absorption by hydrolysis between 56 and 72 days, tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4 weeks, and minimal tissue reaction. Sterilised by ethylene oxide, it offers excellent tensile strength and firm knot tying. Indicated for tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic procedures. Presentation in a box of 12 units. Ref. P1L21XNS1650.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L21XNS1650

Description

1. Commercial Introduction

The Absorbable Multifilament PGLA Suture (Poliglactin 910) from the Prime range by Cahnos is the trusted choice for the professional seeking the perfect balance between handling, knot security and controlled absorption. Presented with a ⅜ circle needle with triangular point in conventional precision cutting with a square body of 16 mm (XNS16), it is designed for procedures that require clean penetration and minimal tissue resistance, both in tissue approximation and in ligatures and ophthalmic surgery.

Manufactured under Prime quality standards (PREMISUT) and available for wholesale distribution, it offers predictable performance and an excellent price-quality ratio for clinics, hospitals, operating theatres, ophthalmic centres and purchasing centres. Price per box of 12 units.

2. Technical Explanation

It is a synthetic absorbable braided (multifilament) suture made from poliglactin 910, a copolymer composed of 90% glycolide and 10% L-lactide. Its absorption mechanism is hydrolysis, a predictable process that does not depend on tissue enzymes and guarantees a constant mass loss between 56 and 72 days, with a fully predictable absorption rate and minimal tissue reaction.

The colourless, non-grooved thread offers a regular surface that facilitates sliding through tissue and firm knot anchorage. The XNS16 mm needle, with a triangular point of conventional precision cutting and square body, prevents rotation in the needle holder and is ideal for firm tissues and surfaces where a clean, controlled passage is required, as well as for plastic and cosmetic surgery. Its colourless colour minimises suture visibility, which is especially advantageous in ophthalmic surgery and aesthetic procedures. It is supplied sterile by ethylene oxide, for single use and without re-sterilisation.

3. Technical Specifications

3.1. General characteristics

Characteristic Detail
Material Polyglactin 910 (PGLA): copolymer 90% glycolide / 10% L-lactide
Structure Braided multifilament, non-ribbed
Thread colour Colourless (violet on demand)
USP size 5/0 (metric 1, diameter 0.10 – 0.149 mm)
Thread length 45 cm
Needle shape ⅜ circle
Needle tip Triangular, conventional precision cutting (extra cutting)
Needle body Square (plastic-cosmetic profile)
Needle size XNS 16 mm (Prime)
Quality Prime (PREMISUT)
Sterilisation Ethylene oxide (EtO)
Presentation Box of 12 units
Reference P1L21XNS1650

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 56 – 72 days
Tensile strength at 2 weeks 75 %
Tensile strength at 3 weeks 50 %
Tensile strength at 4 weeks 30 %
Tissue reaction Minimal
Knot tying Excellent safety

3.3. Size equivalence

USP size Approximate diameter Metric
5/0 0.10 – 0.149 mm 1

Indications: tissue approximation, ligatures, ophthalmic surgery, general surgery and plastic-cosmetic procedures. The price corresponds to a box of 12 units.

4. Equivalences and Cross-References

Poliglactin 910 is the most widely used absorbable multifilament material in the surgical market. This reference behaves as a functional equivalent of the braided poliglactin 910 sutures from the main international manufacturers: Vicryl / Vicryl Plus (Ethicon / Johnson & Johnson), Polysorb (Medtronic) and Safil (B. Braun), all with equivalent absorption and strength retention profiles.

In the Cahnos catalogue, the warehouse version of this same presentation corresponds to reference AMP1L21XNS1650. As alternatives of the same material with other configurations, the following stand out:

Reference Description
P1L21XNS1640 PGLA Prime 3/8, conventional cutting XNS16, USP 4/0, undyed, 45 cm
P1L21XDS1650 PGLA Prime 3/8, reverse cutting XDS16, USP 5/0, colourless, 45 cm
P1L21XHS1650 PGLA Prime ½ circle XHS16, USP 5/0, colourless, 45 cm
P1L22XNS2640 PGLA Prime 3/8, conventional cutting XNS26, USP 4/0, colourless, 75 cm
P1L28XNS1930 PGLA Prime 3/8, conventional cutting XNS19, USP 3/0, colourless, 70 cm
AMP121XNS1650 PGA Prime 3/8, conventional cutting XNS16, USP 5/0, colourless, 45 cm (polyglycolic acid)

5. Selection tips and variants of interest

The USP 5/0 gauge (metric 1) is indicated for delicate tissues, thin skin, mucous membranes and ophthalmic surgery, where a small-diameter thread with good initial strength is required. The ⅜ circle needle with triangular point of conventional precision cutting and square body is especially recommended for firm or difficult-to-penetrate tissues and in plastic-cosmetic surgery, where control and high puncture capacity without tearing are required.

For maximum aesthetic discretion choose the colourless version; if greater visibility in the field is required, the same reference can be requested in violet on demand. If you need a longer tensile support, consider the absorbable monofilament polydioxanone lines; if you are looking for faster absorption, consult the Rapid range of the same family. In the PGLA – Poliglactin 910 range, other lengths (45, 70 and 75 cm), gauges from 6/0 to 2/0 and other needle geometries (DS, XDS, XHS, spatulated and cylindrical HR) are available. Contact our technical-commercial team to optimise your order by boxes and take advantage of special B2B conditions.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament, non-ribbed

Brand

PREMISUT

Thread colour

Colourless (violet on request)

Thread diameter

0.10 – 0.149 mm

Metric gauge (EP)

1

Needle type

Triangular point, conventional precision cutting (extra cutting)

Needle body

Square

Sterilisation

Ethylene oxide (EtO)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic procedures

Presentation

Box of 12 units

Use

Single-use, not re-sterilisable

Reference

P1L21XNS1650

Medida de aguja

XNS 16

Usp

5/0

Color

Colourless, Violet

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Poliglactin 910 Prime · 3/8 Circle Needle Triangular Point Conventional Precision Cutting XNS16 mm Square Body · USP 5/0 · Colourless · 45 cm · Box of 12 units (Ref. P1L21XNS1650)”

Your email address will not be published. Required fields are marked *