Description
1. Product Presentation
The multifilament absorbable suture of Polyglactin 910 (PGLA) in Prime quality is the reference choice for the professional who demands reliable, predictable and safe performance in every procedure. It combines a multifilament structure of excellent handling with controlled absorption, making it an optimal solution for the approximation of soft tissues, surgical ligatures and ophthalmic surgery procedures. Its presentation in a box of 12 units facilitates stock management in operating theatres, clinics and purchasing centres, with special conditions for B2B buyers.
2. Technical explanation of the material and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured as a braided and coated multifilament (fluted surface) that favours the sliding of the thread through tissue and a smooth knot seating. Its absorption occurs by hydrolysis, and not by enzymatic action, which guarantees a predictable reabsorption rate between 56 and 72 days and minimal tissue reaction. The 3/8 circle needle with cylindrical body and trocar point (Tapercut) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them, reducing tissue trauma; this short arc geometry (3/8) is especially valued in reduced surgical fields and in ophthalmic surgery. The USP 4/0 gauge (metric 1.5) is ideal for fine tissues and moderate tension.
3. Technical Specifications
Technical data sheet for reference P1L28DRT1740:
| Parameter | Specification |
|---|---|
| Reference (SKU) | P1L28DRT1740 |
| Brand / Quality | PREMISUT – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided and coated multifilament (grooved) |
| USP / metric gauge | 4/0 (metric 1.5) |
| Thread length | 70 cm |
| Thread colour | Colourless (minimal visual interference) |
| Needle shape | 3/8 circle |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | 17 mm (DRT 17) |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention and absorption profile:
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56–72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. This Prime reference is clinically comparable, in chemical composition, absorption profile (56–72 days) and tensile strength retention, with the main international lines of braided polyglactin 910:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl 910 (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
Within the Cahnos catalogue, its closest equivalent by composition and clinical configuration is reference P1L28HRT1740 (same Prime quality, 17 mm Tapercut trocar point, USP 4/0 gauge and 70 cm colourless thread, with a 1/2 circle arc) and its violet thread variant P1L18HRT1740. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations, with special application in ophthalmic surgery, where minimal trauma and aesthetic scarring are sought. The 3/8 circle needle with 17 mm trocar point (Tapercut) is ideal for tissues of moderate consistency and reduced working fields; if a 1/2 circle arc is preferred, reference P1L28HRT1740 is available, and for very delicate tissues consider the Taperpoint conical point variants (ref. P1L28HR1740) or the Ultra Plus conical point (ref. P1L28HRP1740). As an alternative in polyglycolic acid (PGA) material with the same 17 mm DRT needle, 4/0 gauge and 70 cm colourless strand, reference AMP128DRT1740 is offered. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure and respect the expiry date. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.