We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – 3/8 Circle Needle Cylindrical Body Tapercut Trocar Point DRT17 mm – USP 4/0 Gauge – Colourless Thread 70 cm – Box of 12 units | Ref. P1L28DRT1740

Original price was: 44,90 €.Current price is: 32,60 €.

Absorbable suture PREMISUT Prime of Polyglactin 910 (PGLA), colourless braided multifilament of 70 cm, with 3/8 circle needle, cylindrical body and 17 mm Tapercut trocar point (DRT17). USP 4/0 gauge (metric 1.5), predictable hydrolysis absorption in 56-72 days with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 30 % at 4. Sterile by ethylene oxide, with minimal tissue reaction and excellent knot tying security. Indicated for approximation of soft tissues, ligatures and ophthalmic surgery. Ref. P1L28DRT1740, presentation in a box of 12 units with special B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L28DRT1740

Description

1. Product Presentation

The multifilament absorbable suture of Polyglactin 910 (PGLA) in Prime quality is the reference choice for the professional who demands reliable, predictable and safe performance in every procedure. It combines a multifilament structure of excellent handling with controlled absorption, making it an optimal solution for the approximation of soft tissues, surgical ligatures and ophthalmic surgery procedures. Its presentation in a box of 12 units facilitates stock management in operating theatres, clinics and purchasing centres, with special conditions for B2B buyers.

2. Technical explanation of the material and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured as a braided and coated multifilament (fluted surface) that favours the sliding of the thread through tissue and a smooth knot seating. Its absorption occurs by hydrolysis, and not by enzymatic action, which guarantees a predictable reabsorption rate between 56 and 72 days and minimal tissue reaction. The 3/8 circle needle with cylindrical body and trocar point (Tapercut) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them, reducing tissue trauma; this short arc geometry (3/8) is especially valued in reduced surgical fields and in ophthalmic surgery. The USP 4/0 gauge (metric 1.5) is ideal for fine tissues and moderate tension.

3. Technical Specifications

Technical data sheet for reference P1L28DRT1740:

Parameter Specification
Reference (SKU) P1L28DRT1740
Brand / Quality PREMISUT – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided and coated multifilament (grooved)
USP / metric gauge 4/0 (metric 1.5)
Thread length 70 cm
Thread colour Colourless (minimal visual interference)
Needle shape 3/8 circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 17 mm (DRT 17)
Absorption mechanism Hydrolysis (56–72 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

Tensile strength retention and absorption profile:

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56–72 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglactin 910 is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. This Prime reference is clinically comparable, in chemical composition, absorption profile (56–72 days) and tensile strength retention, with the main international lines of braided polyglactin 910:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic (Covidien) Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl 910 (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
DemeTECH Vitacryl (coated braided polyglactin 910)

Within the Cahnos catalogue, its closest equivalent by composition and clinical configuration is reference P1L28HRT1740 (same Prime quality, 17 mm Tapercut trocar point, USP 4/0 gauge and 70 cm colourless thread, with a 1/2 circle arc) and its violet thread variant P1L18HRT1740. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations, with special application in ophthalmic surgery, where minimal trauma and aesthetic scarring are sought. The 3/8 circle needle with 17 mm trocar point (Tapercut) is ideal for tissues of moderate consistency and reduced working fields; if a 1/2 circle arc is preferred, reference P1L28HRT1740 is available, and for very delicate tissues consider the Taperpoint conical point variants (ref. P1L28HR1740) or the Ultra Plus conical point (ref. P1L28HRP1740). As an alternative in polyglycolic acid (PGA) material with the same 17 mm DRT needle, 4/0 gauge and 70 cm colourless strand, reference AMP128DRT1740 is offered. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure and respect the expiry date. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Reference

P1L28DRT1740

Product line

PREMISUT Prime

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Multifilament braided fluted

Gauge

USP 4/0 (metric 1.5)

Needle body

Cylindrical

Sterilisation

Ethylene oxide (EO), single-use

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DRT 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture – 3/8 Circle Needle Cylindrical Body Tapercut Trocar Point DRT17 mm – USP 4/0 Gauge – Colourless Thread 70 cm – Box of 12 units | Ref. P1L28DRT1740”

Your email address will not be published. Required fields are marked *