Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLA (Polyglactin 910) reference 1L23HR3610, from the Premisut range, is the trusted choice of the professional seeking a synthetic absorbable surgical thread with predictable behaviour, excellent handling and great knot security. It combines a ½ circular cylindrical needle with conical point (taperpoint) of 36 mm with an undyed fluted thread of 90 cm in USP 0 gauge, making it a versatile solution for approximating soft tissues, ligatures and ophthalmic surgery.
It is presented in B2B format in a box of 12 units, with a minimum order of 30 boxes, ensuring continuous supply for operating theatres, ophthalmic clinics, distributors and surgical material purchasing centres, with an excellent quality-price ratio.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, formed into a braided multifilament structure with a fluted finish. This configuration gives it great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (taperpoint) of 36 mm penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, approximation of soft tissues and ligatures. The undyed colour of the thread offers maximum aesthetic discretion and facilitates visibility in delicate surgical fields. Product sterile by ethylene oxide, single-use and not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 1L23HR3610
| Characteristic | Specification |
| Reference (SKU) | 1L23HR3610 |
| Brand / Quality | Premisut – Normal |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Undyed (violet version available in the family, ref. 1L13HR3610) |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 36 mm (HR 36) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This braided, medium-absorption suture is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (C / TC / HR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (HR 36 mm needle, USP 0 gauge, 90 cm thread) is reference 1L13HR3610 in violet; the superior Prime quality is processed as P1L23HR3610 (undyed) or P1L13HR3610 (violet). In the polyglycolic acid (PGA) family with 60-90 day absorption, the alternative is AM123HR3610. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
USP 0 gauge offers an optimal balance between strength and fineness, indicated for soft tissues requiring healing support for 2 to 4 weeks, with special application in ophthalmic surgery and approximation of delicate tissues. The ½ circle taperpoint conical point needle of 36 mm is atraumatic; if you need to penetrate firmer, denser tissues (skin, fascia, sclera), consider the reverse cutting (HS), trocar (HRT) or blunt (HRN) points available in the same range.
| Reference | Variant |
| 1L23HR3610 | PGLA USP 0, HR 36 mm needle, undyed, 90 cm (current product) |
| 1L13HR3610 | PGLA USP 0, HR 36 mm needle, violet, 90 cm (greater visibility in the field) |
| P1L23HR3610 | PGLA Prime USP 0, HR 36 mm needle, undyed, 90 cm (superior quality) |
| 1L23HR3620 | PGLA USP 2/0, HR 36 mm needle, undyed, 90 cm (fine gauge) |
| 1L23HR3602 | PGLA USP 2, HR 36 mm needle, undyed, 90 cm (larger gauge) |
| 1L23HS3620 | PGLA USP 2/0, triangular reverse cutting needle HS 36 mm, undyed (firm tissues) |
| 1L23HRT3601 | PGLA USP 1, trocar needle HRT 36 mm, undyed, 90 cm (fibrous tissues) |
| AM123HR3610 | PGA USP 0, HR 36 mm needle, violet, 90 cm (60-90 day absorption) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.