Description
1. Product Presentation
The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L13HR2630 from the PREMISUT range, is the trusted technical choice for operating theatres, ophthalmic clinics and purchasing centres that need a sterile surgical thread with predictable behaviour, excellent handling and maximum security in knot tying. It combines a ½ circle needle with a cylindrical body and conical Taperpoint point of 26 mm (HR26) with a colourless 90 cm thread in USP gauge 3/0, designed for the approximation of soft tissues, ligatures and ophthalmic surgery, where the discreetness of the thread is especially valued. It is presented in B2B format in a box of 12 units, with a minimum order of 30 boxes, ideal for the continuous supply of your healthcare facility with a very competitive value for money.
2. Technical Explanation
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided non-crimped multifilament structure. This configuration provides great flexibility, low shape memory and smooth sliding of the thread through tissue, with firm and secure knot tying even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75 % at 2 weeks, 50 % at 3 and 30 % at 4), the precise time for the tissue to recover its own resistance.
The HR 26 mm needle, with cylindrical body and conical Taperpoint point, is designed for soft and friable tissues: it passes through by separating the fibres without cutting effect, minimising trauma along the penetration path and facilitating the passage of the thread. The colourless, non-crimped colour offers a regular surface that favours sliding and provides maximum aesthetic discretion, being preferred in ophthalmic surgery and in highly visible areas. The product is sterilised by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 1L13HR2630
| Reference (SKU) | 1L13HR2630 |
| Brand / Quality | PREMISUT – Standard |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Non-grooved braided multifilament |
| Gauge | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread length | 90 cm |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 26 mm (HR 26) |
| Absorption mechanism | Hydrolysis (56 – 72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days, by hydrolysis |
Predictable and controlled absorption, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
3.3. Size equivalence
| USP size | Approximate diameter | Metric size |
| 3/0 | 0.20 – 0.249 mm | 2 |
4. Equivalences and Cross-References
Polyglactin 910 is the most established synthetic absorbable multifilament suture of medium absorption on the market. This reference with HR26 needle behaves as a functional equivalent of the braided polyglactin 910 sutures from the main international manufacturers, with an absorption profile (56 – 72 days) and tensile strength retention equivalent to the following ranges:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| DemeTECH | DemeCRYL / Vitacryl (polyglactin 910) |
| Dolphin Sutures | Petcryl 910 |
| CPT Sutures | CARESORB (polyglactin 910) |
| Meril Life | MITSU |
| Desmo Care | DesmoCryl |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (HR series) |
Within the Cahnos catalogue, its direct equivalent in superior quality is reference P1L13HR2630 (Prime range, same configuration of HR26 needle, gauge 3/0 and colourless 90 cm thread); the warehouse version of this same presentation is processed as AMP1L13HR2630. The indicated equivalences are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
The USP gauge 3/0 (metric 2) combines a fine diameter with excellent initial resistance, making it a very versatile measure for the approximation of soft tissues, ligatures, skin of moderate tension, mucous membranes and ophthalmic surgery. The ½ circle needle with conical Taperpoint point is the most atraumatic option for delicate and friable tissues; for structures of greater consistency, trocar point (HRT) or reverse cutting (HS) needles from the same family may be considered.
| Reference | Variant |
| 1L13HR2630 | PGLA USP 3/0, HR 26 mm needle, colourless, 90 cm (current product) |
| P1L13HR2630 | PGLA Prime quality USP 3/0, HR 26 mm needle, colourless, 90 cm (superior quality) |
| 1L13HR2620 | PGLA USP 2/0, HR 26 mm needle, violet, 90 cm (larger gauge) |
| 1L12HR2630 | PGLA USP 3/0, HR 26 mm needle, violet, 75 cm (shorter thread length) |
| 1L28HR2630 | PGLA USP 3/0, HR 26 mm needle, colourless, 70 cm (compact format) |
| 1L13HR3630 | PGLA USP 3/0, HR 36 mm needle, violet, 90 cm (larger needle size) |
| AM113HR2630 | PGA USP 3/0, HR 26 mm needle, violet, 90 cm (absorption 60 – 90 days) |
All references are supplied in a box of 12 units with a minimum order of 30 boxes, designed for the scheduled replenishment of operating theatre material under B2B conditions. If your protocol requires a longer strength retention (180 – 210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.