Description
1. Product Presentation
The absorbable multifilament suture of polyglactin 910 (PGLA), reference 1L28HR2630 from the Premisut range, is the trusted choice for operating theatres, ophthalmology clinics and purchasing centres that need a sterile synthetic surgical suture with predictable behaviour, excellent handling and maximum knot security. It combines a 1/2 circle needle with a cylindrical body and a 26 mm Taperpoint conical point (HR26), a USP gauge 3/0 (metric 2) and a colourless 70 cm thread, designed for the approximation of soft tissues, ligatures and ophthalmic surgery, where the discreet appearance of the strand on the surgical field is especially valued.
It is supplied in B2B format in a box of 12 units, with a minimum order of 30 boxes, ideal for the continuous supply of your healthcare centre with a very competitive price-quality ratio.
2. Technical Explanation
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure without grooves. This configuration provides great flexibility, low shape memory and smooth passage of the thread through tissue, with firm and secure knot anchorage even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing (75% at 2 weeks, 50% at 3 and 30% at 4), the precise time for the tissue to recover its own resistance.
The 26 mm HR needle, with cylindrical body and Taperpoint conical point, is designed for soft and friable tissues: it passes through by separating the fibres without a cutting effect, minimising trauma along the penetration path and facilitating the passage of the thread. The colourless colour offers a regular surface that favours sliding and provides maximum aesthetic discretion, being preferred in ophthalmic surgery and in highly visible areas. The product is sterilised by ethylene oxide (EtO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 1L28HR2630
| Reference (SKU) | 1L28HR2630 |
| Brand / Quality | Premisut · Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament, non-ribbed |
| Gauge | USP 3/0 (metric 2) |
| Approximate diameter | 0.20 – 0.249 mm (USP/EP standard) |
| Thread length | 70 cm |
| Thread colour | Colourless (violet version available in the family) |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | HR 26 mm |
| Absorption mechanism | Hydrolysis (56 – 72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
3.3. Size equivalence
| USP size | Approximate diameter | Metric size |
| 3/0 | 0.20 – 0.249 mm | 2 |
4. Equivalences and Cross-References
Polyglactin 910 is the most established medium-absorption synthetic multifilament absorbable suture on the market. This reference with HR26 needle behaves as a functional equivalent of the braided polyglactin 910 sutures from the main international manufacturers, with an absorption profile (56 – 72 days) and tensile strength retention equivalent to the following ranges:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| DemeTECH | DemeCRYL / Vitacryl (polyglactin 910) |
| Dolphin Sutures | Petcryl 910 |
| Meril Life | MITSU |
| Laboratory Aragó (Premisut) | Range of polyglactin 910 with 1/2 circle cylindrical needles (HR series) |
Within the Cahnos catalogue, its equivalent in Prime quality with the same configuration (HR 26 mm needle, gauge 3/0 and colourless 70 cm thread) is reference P1L28HR2630, and the version with 90 cm thread corresponds to 1L13HR2630. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
The USP gauge 3/0 (metric 2) combines a fine diameter with excellent initial strength, making it a very versatile size for the approximation of soft tissues, ligatures, skin of moderate tension, mucous membranes and ophthalmic surgery. The 1/2 circle needle with Taperpoint conical point is the most atraumatic option for delicate and friable tissues; for structures of greater consistency, trocar point (HRT) or reverse cutting (HS) needles from the same family may be considered.
| Reference | Variant |
| 1L13HR2630 | PGLA USP 3/0, HR 26 mm needle, colourless, 90 cm (longer thread length) |
| P1L28HR2630 | PGLA Prime quality USP 3/0, HR 26 mm needle, colourless, 70 cm (superior quality) |
| 1L28HR2620 | PGLA USP 2/0, HR 26 mm needle, colourless, 70 cm (larger gauge) |
| 1L28HR2610 | PGLA USP 0, HR 26 mm needle, colourless, 70 cm (larger gauge) |
| 1L28HR3630 | PGLA USP 3/0, HR 36 mm needle, colourless, 70 cm (larger needle) |
| 1L28HR2230 | PGLA USP 3/0, HR 22 mm needle, colourless, 70 cm (smaller needle) |
| 1L18HRT2630 | PGLA USP 3/0, HRT 26 mm trocar point needle, violet, 70 cm (firmer tissues) |
| 1L12HR2630 | PGLA USP 3/0, HR 26 mm needle, violet, 75 cm (greater thread visibility) |
All references are supplied in a box of 12 units with a minimum order of 30 boxes, designed for the scheduled replenishment of operating theatre material under B2B conditions. If your protocol requires a longer strength retention (180 – 210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.