We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 – 1/2 Circle Cylindrical Body Needle Blunt Point HRN 48 mm – USP 0 Gauge – Violet Thread 90 cm – Ref. 1L13HRN4810 – Box 12 units

Original price was: 29,90 €.Current price is: 23,20 €.

Multifilament absorbable suture of polyglactin 910 (PGLA) from the Premisut range with ½ circle cylindrical body needle and blunt point of 48 mm (HRN 48), USP 0 gauge and violet ribbed thread 90 cm. Predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 30 % at 4 weeks. Sterilised by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Recommended for tissue approximation, ligatures and ophthalmic surgery. Ref. 1L13HRN4810. Presentation in box of 12 units with minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L13HRN4810

Description

1. Introduction

The multifilament absorbable suture of polyglactin 910 (PGLA) reference 1L13HRN4810 from the Premisut range is the ideal surgical closure solution for the professional who demands a flexible, safe thread with a totally predictable absorption profile. Its ½ circle needle, cylindrical body and blunt point of 48 mm (HRN 48) penetrates tissues minimising trauma, making it especially suitable for soft tissue approximation, ligatures and ophthalmic surgery.

It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for B2B supply to operating theatres, ophthalmic clinics and purchasing centres. It is presented in a box of 12 units, with a minimum order of 30 boxes, ensuring continuous supply for your healthcare centre.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a ribbed finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, comfortable glide and firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing: it retains 75 % of its tensile strength at 2 weeks, 50 % at 3 weeks and 30 % at 4 weeks, while the tissue recovers its own strength.

The ½ circle needle with cylindrical body and blunt point of 48 mm penetrates tissues without cutting them, reducing the risk of tearing and making it especially recommended in ophthalmology, soft tissue approximation and ligatures. The product is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 1L13HRN4810

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 0 (metric 3.5)
Colour Violet
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Tip type Blunt point (atraumatic)
Needle size HRN 48 mm
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) 1L13HRN4810

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglactin 910 is the reference synthetic absorbable material in the European market. This suture is clinically equivalent in composition, absorption profile and mechanical behaviour to the braided polyglactin 910 lines of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided coated polyglactin 910, violet)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Absorbable braided polyglactin 910 range
Laboratory Aragó Poliglactina 910 range with cylindrical needles (HR / HRN series)

Within the Cahnos catalogue, the direct counterpart in higher gauge is reference 1L13HRN4801 (PGLA, HRN 48 mm needle, USP 1, violet, 90 cm) and the alternative in polyglycolic acid with the same needle is reference AM113HRN4810 (PGA, HRN 48 mm needle, USP 0, violet, 90 cm, absorption 60-90 days). The equivalences indicated are for guidance; for a formal substitution, please consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during a healing period of 2 to 4 weeks. The blunt point (HRN) is the most atraumatic option for delicate tissues; the conical point (HR) offers easier penetration and the trocar point is intended for somewhat denser tissues.

Reference Variant
1L13HRN4810 PGLA USP 0, blunt point HRN 48 mm, violet, 90 cm (current product)
1L13HRN4801 PGLA USP 1, blunt point HRN 48 mm, violet, 90 cm
AM113HRN4810 PGA USP 0, blunt point HRN 48 mm, violet, 90 cm (absorption 60-90 days)
1L13HR4810 PGLA USP 0, taper point HR 48 mm, violet, 90 cm
1L13HRN4010H PGLA USP 0, reinforced blunt point HRN 40 mm, violet, 90 cm
1L13HRT4010 PGLA USP 0, trocar point HRT 40 mm, violet, 90 cm
1L13HS4810 PGLA USP 0, reverse cutting triangular point HS 48 mm, violet, 90 cm

For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in a box of 12 units; the minimum order is 30 boxes. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA)

Composition

90 % glycolide / 10 % L-lactide

Thread structure

Multifilament braided fluted

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Tip type

Blunt point (atraumatic)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Product line

Premisut

Reference

1L13HRN4810

Medida de aguja

HRN 48

Usp

0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Blunt tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 – 1/2 Circle Cylindrical Body Needle Blunt Point HRN 48 mm – USP 0 Gauge – Violet Thread 90 cm – Ref. 1L13HRN4810 – Box 12 units”

Your email address will not be published. Required fields are marked *