Description
1. Introduction
The Prime-quality absorbable multifilament polyglactin 910 (PGLA) suture from the Premisut range is the reference choice in the operating theatre for surgical teams seeking a high-performance synthetic thread at a competitive price. It is supplied with a 1/2 circle needle, cylindrical body and blunt point of 48 mm (HRN48), USP 1 gauge and a 90 cm violet thread with a grooved finish.
Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos for hospitals, private clinics and wholesalers in the sector. It is especially indicated for the approximation of soft tissues, ligatures and ophthalmic surgery, where precision, manageability and predictable absorption are required during the first weeks of healing. Reference P1L13HRN4801, with a minimum order of 30 boxes.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish provides great flexibility, low memory and a contained coefficient of friction that favours the sliding of the thread through tissue and knot tying with maximum security.
The thread is absorbed by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, maintaining constant wound support: it retains 75% of the initial tensile strength at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. It presents minimal tissue reaction and excellent tensile strength, with an ideal profile for tissues requiring support for 2 to 4 weeks.
The 1/2 circle needle with cylindrical body and blunt point of 48 mm passes through tissues by separating the fibres without cutting them, which minimises trauma to delicate structures; it is especially recommended in ophthalmic surgery and in the approximation of friable tissues. The violet colouring of the thread guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
| General characteristics | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Colour | Violet |
| Gauge | USP 1 |
| Thread length | 90 cm |
| Needle: shape | ½ circle |
| Needle: body | Cylindrical |
| Needle: point | Blunt point (blunt point) |
| Needle: radius / code | HRN 48 mm, Prime quality |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L13HRN4801 |
Tensile strength retention profile:
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures of medium absorption on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon | Vicryl (braided polyglactin 910, violet) |
| B. Braun | Safil / Surgicryl (braided poliglactin 910, violet) |
| Aragó Laboratory (Aragó Sutures) | Polyglactin 910 range with 1/2 circle needles (HR / RN series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP113HRN4801 (PGA Prime, HRN48 mm blunt point needle, USP 1, violet, 90 cm). In the same PGLA family, it shares needle geometry with reference P1L13HRN4810 (USP 0 gauge).
5. Selection tips and variants of interest
To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the necessary gauge depending on the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks.
- P1L13HRN4801: PGLA Prime USP 1, HRN 48 mm blunt point needle, violet, 90 cm (current product).
- P1L13HRN4810: PGLA Prime USP 0, same HRN 48 mm blunt point needle, violet, 90 cm (finer gauge for delicate tissues).
- P1L13HR4801: PGLA Prime USP 1, HR 48 mm taper point needle, violet, 90 cm (atraumatic point for soft tissues).
- P1L13HRN4001H: PGLA Prime Heavy USP 1, HRN 40 mm blunt point needle, violet, 90 cm (shorter needle for reduced fields).
- P1L13HRT4010: PGLA Prime USP 0, HRT 40 mm trocar point (tapercut) needle, violet, 90 cm (for fibrous tissues such as the sclera).
- AMP113HRN4801: PGA Prime alternative with the same HRN 48 mm needle, USP 1, violet, 90 cm.
In ophthalmic surgery, prioritise 1/2 circle needles: the blunt point minimises the risk of injury to delicate tissues, while the trocar point is reserved for fibrous and dense structures. Always check the integrity of the packaging before each procedure and respect the traceability required by the centre. Consult our commercial team for special volume conditions: the minimum order is 30 boxes, with scheduled deliveries for hospitals and purchasing centres.





Reviews