Description
1. Commercial presentation
At Cahnos we offer the Prime-quality absorbable multifilament Poliglactina 910 (PGLA) suture, reference P1L18RHRP2601, designed for professionals who demand reliable, manageable and predictable performance in the operating theatre. This presentation combines a 1/2 circle cylindrical-bodied needle with an Ultra Plus Trocar point of 26 mm (HRP26), a USP 1 gauge and a 70 cm violet thread with high visibility in the surgical field. It is an excellent option for tissue approximation, ligatures and ophthalmic surgery, with predictable absorption that avoids the need for later removal. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use in the operating theatre.
2. Technical Explanation
Poliglactina 910 is a synthetic copolymer composed of 90 % glycolide and 10 % L-lactide, structured as a coated braided multifilament that ensures smooth passage through tissue, excellent knot tying and high initial tensile strength. Its absorption occurs by hydrolysis over an interval of 56 to 72 days, with progressive and predictable loss of strength and minimal tissue reaction, making it especially safe in delicate tissues. The 1/2 circle cylindrical-bodied needle with Ultra Plus Trocar point (designation HRP26) penetrates tissue with less resistance and without a cutting effect on adjacent tissue, minimising trauma and improving control in areas such as the ocular surface and lax tissues. The product is supplied sterile by ethylene oxide (EO) and is single-use; it must not be re-sterilised.
3. Technical Specifications
Main characteristics of reference P1L18RHRP2601:
| Parameter | Value |
|---|---|
| Reference | P1L18RHRP2601 |
| Quality | Prime (Premisut) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Coated braided multifilament |
| USP / metric gauge | USP 1 (metric 4) |
| Thread length | 70 cm |
| Colour | Violet |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle size | 26 mm (HRP26) |
| Needle tip | Trocar Ultra Plus (taperpoint type) |
| Absorption | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EO) |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention and absorption profile:
| Period | Tensile strength retention |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days by hydrolysis |
4. Equivalences and Cross-References
Poliglactina 910 is one of the classic compositions in the market for synthetic absorbable multifilament sutures. This Prime reference from Cahnos is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl lines from Ethicon (Johnson & Johnson), the Safil range from B.Braun, Polysorb from Medtronic/Covidien and the poliglactina 910 ranges from SMI (Surgicryl). The HRP needle with Ultra Plus Trocar point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers for 26 mm needles with cylindrical body. Within the Cahnos catalogue, this reference is part of the PGLA Prime line with HRP needle and Ultra Plus Trocar point, available in different gauges, colours and thread lengths.
5. Selection tips and variants of interest
The USP 1 gauge with 26 mm HRP needle and Ultra Plus Trocar point is a balanced choice for tissue approximation, ligatures and precision ophthalmic surgery. If you need the same profile in other gauges, the HRP26 family with 70 cm thread is available: P1L18RHRP2610 (USP 0, violet), P1L18RHRP2620 (USP 2/0, violet) and P1L18RHRP2602 (USP 2, violet); in colourless version, references P1L28RHRP2610, P1L28RHRP2620 and P1L28RHRP2630 are the direct alternatives. For other thread lengths, see P1L13RHRP2630 (USP 3/0, violet, 90 cm) or the HRP36 family (P1L13RHRP3602, USP 2, 90 cm). As it is single-use material, it must be discarded after the procedure and stored in a cool, dry place, protected from sunlight and inside its sterile packaging until use. Consult our technical-commercial team for special volume conditions and hospital supply contracts.



Reviews