Description
1. Commercial presentation
At Cahnos we offer the Prime-quality absorbable multifilament Polyglactin 910 (PGLA) suture, reference P1L13RHRP2620, designed for professionals who demand reliable, manageable and predictable performance in the operating theatre. This presentation combines a 1/2 circle cylindrical-body HRP 26 mm needle with Trocar Ultra Plus point, USP 2/0 gauge and a 90 cm violet thread with high visibility on tissue. It is an excellent option for soft tissue approximation, ligatures and ophthalmic surgery, with predictable absorption that avoids the need for removal. It is supplied in a box of 12 units, sterilised by ethylene oxide and ready for immediate use, both in the sterilisation centre and in standard storage.
2. Technical Explanation
Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, structured as a coated braided multifilament that ensures smooth passage through tissue, excellent knot tying and high initial tensile strength. Its absorption occurs by hydrolysis over an interval of 56 to 72 days, with progressive and predictable loss of strength and minimal tissue reaction, making it especially safe in delicate tissues.
The 1/2 circle cylindrical-body needle with Trocar Ultra Plus point (designation HRP26) penetrates tissue with lower penetration resistance and without a cutting effect on adjacent tissue, minimising trauma and improving control in precision areas such as the ocular surface and lax tissues. The product is supplied sterilised by ethylene oxide (EO) and is single-use.
3. Technical Specifications
Main features of reference P1L13RHRP2620:
| Reference | P1L13RHRP2620 |
| Material | Polyglactin 910 (PGLA): 90% glycolide / 10% L-lactide |
| Thread structure | Multifilament braided coated (fluted) |
| USP / metric gauge | 2/0 (metric 3) |
| Thread length | 90 cm |
| Colour | Violet |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle size | 26 mm (HRP 26 Prime) |
| Needle tip | Trocar Ultra Plus (taperpoint conical tip) |
| Absorption | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (EO), single-use |
| Quality | Prime (Premisut) |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention and absorption profile:
| Period | Tensile strength retention |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days by hydrolysis |
4. Equivalences and Cross-References
Polyglactin 910 is one of the classic compositions in synthetic multifilament absorbable suture on the market. This Prime reference from Cahnos is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl™ lines from Ethicon (Johnson & Johnson), to the Safil range from B. Braun, to Polysorb from Medtronic/Covidien and to the polyglactin 910 ranges from SMI (Surgicryl). The HRP needle with Trocar Ultra Plus point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers.
Within the Cahnos catalogue, this reference shares a family with the PGLA Prime line with 26 mm HRP needle: P1L18RHRP2620 (USP 2/0, violet, 70 cm) and P1L13RHRP2630 (USP 3/0, violet, 90 cm), as well as with the 36 mm HRP line: P1L13RHRP3620 (USP 2/0, violet, 90 cm), P1L13RHRP3630 (USP 3/0) and the colourless versions P1L28RHRP3620 and P1L28RHRP3601.
5. Selection tips and variants of interest
The USP 2/0 gauge with 26 mm HRP needle and Trocar Ultra Plus point is a balanced choice for general surgery, tissue approximation and precision ligatures, as well as for ophthalmic surgery in areas of restricted access. If you prefer the same format with a shorter thread, reference P1L18RHRP2620 (70 cm) is available; for a needle with a larger radius in the same gauge, consider P1L13RHRP3620 (HRP 36 mm). For smaller gauges with the same HRP26 needle profile, see P1L13RHRP2630 (USP 3/0) or its 70 cm variant P1L18RHRP2630. If you prefer a conventional conical point without trocar, reference P1L13HR2620 (HR26, USP 2/0) is the direct alternative.
As this is sterile single-use material, it must be disposed of after the procedure and stored in a cool, dry place, protected from sunlight and inside its sterile packaging until use. Contact our technical-commercial team for special volume conditions and hospital supply contracts.





Reviews