Description
1. Product Presentation
The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range, reference P1L18RHRP3010, is the choice of the professional seeking a resorbable thread with predictable behaviour, excellent handling and maximum knot security. It combines a ½ circle cylindrical body HRP 30 mm needle with a fluted Trocar Ultra Plus point, USP 0 gauge and a 70 cm violet thread with excellent visibility in the surgical field. Each unit is supplied sterile and ready to use, with the maximum quality of the Premisut line and the guarantee of professional distribution by Cahnos for hospitals, private clinics, operating theatres and purchasing centres. Presentation in a box of 12 units.
2. Technical explanation of the material and procedure
Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, structured as a braided and coated multifilament. This configuration provides great flexibility, low memory, smooth passage through tissue and secure, stable knot tying, with minimal tissue reaction. Its absorption occurs by hydrolysis over an interval of 56 to 72 days, ensuring progressive and predictable loss of strength, without depending on the patient’s enzymatic activity and without the need for subsequent removal.
The ½ circle cylindrical body needle with fluted Trocar Ultra Plus point (designation HRP 30) passes through tissues with less resistance and without cutting effect on adjacent tissue, minimising surgical trauma and improving control in delicate areas such as the ocular surface and lax tissues. The violet colour of the thread ensures optimal visibility throughout the procedure. The product is sterilised by ethylene oxide (EO) and is single-use.
3. Technical Specifications
Main characteristics of reference P1L18RHRP3010:
| Characteristic | Specification |
| Reference | P1L18RHRP3010 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA): copolymer 90% glycolide / 10% L-lactide |
| Thread structure | Braided and coated multifilament |
| USP / metric gauge | USP 0 (metric 3.5) |
| Thread length | 70 cm |
| Thread colour | Violet (colourless version available in the family) |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle size | 30 mm (HRP 30 Prime) |
| Needle tip | Trocar Ultra Plus fluted (Taperpoint type) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Absorption and tensile strength retention profile:
| Period | Tensile strength retention |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56 – 72 days by hydrolysis |
4. Equivalences and Cross-References
Polyglactin 910 is the classic composition of synthetic absorbable multifilament sutures of medium absorption. This Prime reference is clinically equivalent, both in chemical composition and in absorption profile (56-72 days) and tensile strength retention, to the Vicryl™ / Vicryl Plus (Ethicon – Johnson & Johnson), Safil (B. Braun), Polysorb (Medtronic/Covidien) and Surgicryl (SMI) lines. The HRP needle with fluted Trocar Ultra Plus point is functionally equivalent to the reinforced conical needles with penetration point (taperpoint type) used by the main manufacturers for resistant but delicate tissues.
Within the Cahnos catalogue, this reference shares a family with the variants with HRP 30 mm needle: P1L18RHRP3020 (gauge 2/0, violet, 70 cm) and P1L18RHRP3030 (gauge 3/0, violet, 70 cm), as well as P1L12RHRP3001 (USP 1 gauge, 75 cm thread). For a larger radius needle with the same USP 0 gauge, see P1L18RHRP3610 (HRP 36 mm) and P1L18RHRP4010 (HRP 40 mm).
5. Selection tips and variants of interest
The USP 0 gauge with HRP 30 mm needle and Trocar Ultra Plus point offers an optimal balance between strength and delicacy, suitable for approximation of soft tissues, ligatures and ophthalmic surgery, as well as for fine tissue planes and fixation techniques. For tissues of lower strength or more superficial planes, consider the lower gauges (USP 2/0, ref. P1L18RHRP3020, or 3/0, ref. P1L18RHRP3030); for structures subjected to greater traction, consider the USP 1 gauge of the same family (P1L12RHRP3001).
Check the needle radius (HRP 26, 30, 36, 40, 45 or 48 mm) according to the depth and surgical area, as well as the thread length (70, 75 or 90 cm) according to the number of stitches planned. For a 90 cm thread with HRP 36 mm needle, reference P1L13RHRP3610 is available; there are also colourless versions in the family (P1L28RHRP3601 and P1L28RHRP3620). As it is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. Contact our technical-commercial team for special conditions by volume and hospital supply contracts.




Reviews