Description
1. Introduction
The multifilament absorbable suture of polyglactin 910 (PGLA) from the Prime range by Premisut is the reference choice in the operating theatre for professionals seeking reliable, predictable, high-quality performance in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circular needle with triangular point and reverse cutting edge of 40 mm (HS) and its violet braided thread of 70 cm ensure precise penetration even in firm tissues, optimal visibility in the surgical field and exceptional handling in every stitch.
Manufactured under strict quality standards, this suture combines minimal tissue reaction with excellent tensile strength and optimal knot security, ensuring consistent clinical results in every procedure. Commercial presentation in a box of 12 units, with a minimum order of 30 boxes to guarantee continuous supply for the healthcare centre.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. It is configured in a braided multifilament structure with a grooved finish, which provides a regular surface that favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes it suitable for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ½ circle needle with triangular body and point with reverse cutting edge of 40 mm is designed to penetrate firm, dense tissues with controlled trauma, avoiding tears. It is especially indicated for tissue approximation, ligatures and ophthalmic and general surgery procedures. The product is supplied sterile by ethylene oxide, single-use and with no possibility of re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 |
| Colour | Violet |
| Needle shape | ½ circle |
| Tip type | Triangular with reverse cutting (triangular body and point) |
| Needle size | HS 40 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide |
| Presentation | Box of 12 units |
| Reference (SKU) | P1L18HS4001 |
Tensile strength retention profile:
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon | Vicryl (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Aragó Sutures | Polyglactin 910 range with ½ circle needles (HS / TC series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP118HS4001 (PGA Prime, triangular HS 40 mm needle, USP 1, violet, 70 cm), ideal when a 60 to 90 day absorption profile is preferred. To configure the complete operating theatre range, it is recommended to combine this reference with the variants of the same family detailed in the following section.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge depending on the anatomical area. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks.
| Reference | Variant |
|---|---|
| P1L18HS4001 | PGLA Prime USP 1, triangular HS 40 mm needle, violet, 70 cm (current product) |
| P1L18HR4001 | PGLA Prime USP 1, HR 40 mm cylindrical needle with conical point, violet, 70 cm (more atraumatic in delicate tissues) |
| P1L13HS4001 | PGLA Prime USP 1, triangular HS 40 mm needle, violet, 90 cm (longer thread length) |
| P1L18HRT4001-2 | PGLA Prime USP 1, double HRT 40 mm needle with trocar point, violet, 70 cm |
| P1L12DS4001 | PGLA Prime USP 1, 3/8 triangular DS 40 mm needle, violet, 75 cm |
| AMP118HS4001 | PGA Prime USP 1, triangular HS 40 mm needle, violet, 70 cm (absorption profile of 60 to 90 days) |
If you need longer strength retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. For tissues with faster absorption needs, consult the rapid-absorption polyglactin 910 range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply for your healthcare centre.





Reviews