Description
1. Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the PREMISUT range is the reference technical solution for professionals seeking a surgical thread with predictable performance, excellent handling and high knot security in soft tissue approximation, ligation and ophthalmic surgery. Its ½ circle needle with a 48 mm reverse cutting triangular point (HS48) offers firm and controlled penetration, ideal for consistent tissues, while the 90 cm fluted violet thread ensures optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable suture, sterile and single-use, with a very competitive price-quality ratio for B2B supply to operating theatres, clinics and purchasing centres. Commercial presentation in boxes of 12 units and a minimum order of 30 boxes, ensuring continuous supply for your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. It is presented in a braided multifilament structure with a fluted finish, which provides a regular surface that favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 2.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes it suitable for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with a 48 mm reverse cutting triangular point penetrates firm and dense tissues with controlled trauma, being especially indicated for tissue approximation, ligation and ophthalmic and general surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 1L13HS4802
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2 (metric 5) |
| Colour | Violet |
| Needle | ½ circle, triangular reverse cutting body and point |
| Needle size | HS 48 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | 1L13HS4802 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligation and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Braided polyglactin 910 suture in violet colour |
| B. Braun | Braided polyglactin 910 suture in violet colour |
| Medtronic | Absorbable braided polyglactin 910 range |
| Laboratory Aragó | Range of polyglactin 910 with ½ circle needles (HS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AM113HS4802 (PGA, HS48 mm triangular needle, USP 2, violet, 90 cm). In the PGLA Prime range, references P1L13HS4801 (USP 1) and P1L13HS4810 (USP 0) stand out, with the same HS48 mm triangular needle and 90 cm violet thread, and the colourless version of the same family is processed as 1L28HS2230 in fine gauges. To configure the complete operating theatre range, it is recommended to combine this reference with the variants detailed in the following section.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2 gauge (metric 5) is indicated for tissues requiring greater initial resistance: deep planes, fascia, aponeurosis, high-tension closures and ligatures. Polyglactin 910 offers an excellent balance between initial resistance and predictable absorption for soft tissues with healing of 2 to 4 weeks.
- 1L18HS2230: PGLA ½ circle triangular HS22 mm, USP 3/0, violet, 70 cm (fine size for delicate tissues).
- 1L28HS2230: PGLA ½ circle triangular HS22 mm, USP 3/0, colourless, 70 cm (maximum aesthetic discretion).
- 1L13HR4802: PGLA ½ circle cylindrical HR48 mm, USP 2, violet, 90 cm (conical point for soft tissues).
- AM113HS4002: PGA ½ circle triangular HS40 mm, USP 2, violet, 90 cm (alternative in polyglycolic acid).
- P1L13HR4801: PGLA Prime ½ circle cylindrical HR48 mm, USP 1, violet, 90 cm (Prime quality, conical point).
For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.