Description
1. Introduction
The absorbable multifilament PGLA (polyglactin 910) Prime suture, reference P1L18HS3610, is the reference technical solution for professionals seeking a surgical thread with predictable behaviour, excellent handling and great knot security in soft tissue approximation, ligatures and ophthalmic surgery. Its ½ circular needle with reverse cutting triangular point of 36 mm (HS 36) ensures firm and controlled penetration, while the 70 cm violet grooved thread offers optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic absorbable, sterile and single-use medical device, with a very competitive price-quality ratio for B2B procurement for operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ensuring continuous supply for your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in medium gauges such as USP 0 (metric 3.5).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circular needle with reverse cutting triangular point (inverted triangle) of 36 mm penetrates firm and dense tissues with controlled trauma, avoiding tears, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
General characteristics of reference P1L18HS3610:
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 0 (metric 3.5) |
| Colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | HS 36 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS3610 |
Tensile strength retention profile:
| Time | Tensile Strength (%) |
|---|---|
| 2 weeks | 75% |
| 3 weeks | 50% |
| 4 weeks | 30% |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (470xx series and HS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP118HS3610 (PGA, HS 36 mm triangular needle, USP 0, violet, 70 cm), and in the same PGLA Prime range the variant with a conical point (more atraumatic) corresponds to reference P1L18HR3610 (cylindrical HR 36 mm, USP 0, violet, 70 cm).
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 0 gauge (metric 3.5) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures. The 36 mm reverse cutting triangular needle is especially recommended for firm tissues and in ophthalmic surgery, where the needle passage must be clean and without tearing.
| Reference | Variant |
|---|---|
| P1L18HS3610 | PGLA Prime USP 0, triangular needle HS 36 mm, violet, 70 cm (current product) |
| P1L18HS3630 | PGLA Prime USP 3/0, same HS 36 mm needle (fine gauge) |
| P1L13HS3610 | PGLA Prime USP 0, same HS 36 mm needle, violet, 90 cm (longer thread length) |
| P1L18HR3610 | PGLA Prime USP 0, cylindrical HR 36 mm needle (conical point, more atraumatic) |
| P1L12DS3610 | PGLA Prime USP 0, 3/8 circle DS 36 mm needle, violet, 75 cm (ophthalmic profile) |
| AMP118HS3610 | PGA Prime USP 0, HS 36 mm needle (absorption profile of 60 to 90 days) |
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.