Description
1. Product Presentation
The Prime range polydioxanone (PDO) absorbable monofilament suture is the reference choice when tissue requires prolonged support during healing with fully predictable absorption. This presentation combines a 70 cm violet thread in USP 5/0 gauge with a ⅜ circle needle, cylindrical body and trocar point (Tapercut) of 13 mm (DRT13), a geometry designed to penetrate medium and firm consistency tissue with great precision and minimal trauma.
Available in a box of 12 sterile units, it is a reliable and cost-effective solution for general surgery departments, paediatric cardiovascular surgery operating theatres, ophthalmology units and hospital purchasing centres seeking quality homogeneity with CE marking and gauges conforming to USP/European Pharmacopoeia.
2. Technical Explanation
Polydioxanone is a synthetic absorbable polyester —a poly(p-dioxanone) polymer— that degrades by hydrolysis, a mechanism independent of the patient’s enzymatic activity that guarantees a highly reproducible absorption kinetics, completing between 180 and 210 days. Being a monofilament, the thread has no wicking effect or capillarity: it reduces bacterial adherence, facilitates sliding through tissue and minimises the inflammatory response compared to multifilament threads. Its firm feel and excellent knotting capacity make it suitable for ligatures and sutures of planes subjected to sustained tension during the critical healing phase.
The DRT13 needle combines a cylindrical body with a non-cutting section and a sharp trocar point (Tapercut): it penetrates intermediate and firm consistency tissues with lower penetration force, separating fibres without a cutting effect on adjacent tissue. Its ⅜ circle arc (approx. 135°) is especially valued in reduced surgical fields and precision techniques. The highly visible violet colour improves thread contrast on the surgical field. It is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics
| Property | Specification |
|---|---|
| Material | Polydioxanone (PDO), synthetic absorbable monofilament polymer |
| Thread structure | Monofilament (non-braided) |
| Quality / range | Prime |
| Gauge / size | USP 5/0 (metric 1) · conforming to USP / European Pharmacopoeia |
| Approximate diameter | 0.100 – 0.149 mm (USP/EP standard) |
| Thread length | 70 cm (1 thread per unit) |
| Thread colour | High-visibility violet |
| Needle shape | 3/8 circle (approx. 135°) |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | DRT13 – 13 mm (Prime) |
| Swaged | 1 needle per suture |
| Absorption mechanism | Hydrolysis (180–210 days) |
| Sterilisation | Ethylene oxide (EO) — sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general surgery, paediatric cardiovascular tissues and ophthalmology |
| Presentation | Box of 12 sterile units (individual pouches) |
| Factory reference / SKU | P418DRT1350 / AMP418DRT1350 |
3.2. Tensile strength retention profile
| Time after implantation | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 4 weeks | 60–70 % |
| 8 weeks | 45 % |
| Complete absorption | 180–210 days by hydrolysis |
This prolonged strength retention profile is maintained during the critical healing phase of slow-healing tissues, which is why its use is recommended in closures of fascia, aponeurosis, skin and structures subjected to sustained traction.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 5/0 | 1 (EP) | 0.100 – 0.149 mm (USP/EP) |
4. Equivalences and Cross-References
Polydioxanone monofilament is the material basis of the market reference lines for long-lasting absorbable sutures (PDS-type family). For the verified configuration of this data sheet (⅜ circle needle, cylindrical body and 13 mm Tapercut trocar point, USP 5/0 gauge, 70 cm violet thread), no reference from another manufacturer has been found in public sources that matches field by field (material, gauge, ⅜ curvature, trocar point family, 13 mm size, 70 cm length and colour), so it is not possible to declare an exact verified reference equivalence with third parties.
There is no equivalence table validated by the manufacturer for this specific configuration; consult the technical department of Cahnos before use in tenders. As homologous market families, to be verified code by code in their official technical data sheet before any substitution, the following are cited: the PDS II® and PDS Plus® lines from Ethicon (the latter with antibacterial triclosan coating, indicated only where its use is approved), the MonoPlus® line from B. Braun/Aesculap (polydioxanone monofilament), the Surgicryl PDO line from SMI and the Maxon line from Medtronic/Covidien (made of polyglyconate, a different polymer, so its absorption profile must be verified). All must be checked field by field in their official data sheet: USP gauge, thread length, colour, curvature, body, point and needle size, as well as the attachment. The cited brands belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
When choosing a PDO suture, always verify the USP gauge according to the tissue plane: fine gauges (4/0 to 6/0) for skin, subcutaneous tissue and delicate tissues —as is the case with this reference—, 3/0 and 2/0 for general soft tissue and USP 0 and above for fascia and planes under tension. Needle geometry is also decisive: the trocar point (DRT) is indicated for medium and firm consistency tissues with controlled penetration, while the conical point (DR/HR) is reserved for delicate and well-perfused tissues (vessels, parenchyma) and the reverse cutting triangular point (DS) for fibrous and resistant tissues.
| Reference | Variant of interest |
|---|---|
| AMP418DRT1350 (P418DRT1350) | Current product: PDO Prime USP 5/0, ⅜ trocar point needle DRT 13 mm, violet, 70 cm |
| AMP418DRT1360 | PDO Prime USP 6/0, same DRT 13 mm needle, violet, 70 cm (finer gauge) |
| AMP418DR1350-2 (P418DR1350-2) | PDO Prime USP 5/0, double ⅜ conical point needle 13 mm, violet, 70 cm |
| AMP411DS1950 | PDO Prime USP 5/0, DS19 reverse cutting needle, violet, 45 cm |
| AM411DS1950 | PDO Normal quality USP 5/0, DS19 reverse cutting needle, violet, 45 cm (cost alternative) |
| AMP412DS1930 | PDO Prime USP 3/0, DS19 reverse cutting needle, 75 cm (for firmer planes) |
As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or other gauges, lengths and colours made to order, contact the technical-commercial team at Cahnos.