We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Adult Type D SpO2 Clip Sensor – 0.9 m Cable – Replacement for K12, K15 and Oxy 110 Monitors | Ref. 35317

66,50 €

Pulse oximeter sensor adult SpO2 clip type, with 0.9 m type D cable, as an original replacement for the vital signs monitors K12, K15 (connection cable ref. 35318 required) and Oxy 110. Reusable part designed for continuous, non-invasive monitoring of oxygen saturation and pulse rate, with easy-to-place clip fixation, stable hold and reliable reading. Class II A medical device. Always verify the exact reference of your monitor before placing the order and consult our technical-commercial team for B2B terms, compatibility and supply.

Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35317
Tags

Description

1. Introduction

The adult SpO2 pulse oximeter clip sensor, reference 35317, is the original replacement part for the vital signs monitors K12, K15 and Oxy 110. It is a reusable catheter with an integrated type D cable of 0.9 m that allows the worn or damaged measuring part of your equipment to be replaced quickly and safely, maintaining the reliability of oxygen saturation and pulse rate measurement in the day-to-day of the practice, health centre or clinic.

As an original manufacturer spare part, it guarantees compatibility and performance in line with the monitor’s factory configuration. For the K12 and K15 models, the connection cable with reference 35318 must also be purchased; the Oxy 110 model connects directly.

2. Technical explanation

Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed and detects differential absorption according to the degree of blood oxygenation. This clip sensor is placed on the adult patient’s finger and maintains a stable hold during continuous monitoring, transmitting the signal to the monitor via the 0.9 m type D cable.

As a reusable measuring element and a spare part, it allows the original monitor part to be replaced without having to replace the entire device, optimising maintenance costs and equipment availability. The 0.9 m cable length is suitable for connection close to the patient at bedside stations, stretchers and examination tables.

3. Technical Specifications

Product data

Manufacturer GIMA
Sales unit 1 unit
Device type Medical device
Device class II A
CND C900301
GMDN 36087
EAN 8023279353174

Available references

Reference (SKU Cahnos) GM35317
Manufacturer reference 35317
Connection cable for K12 / K15 35318

Sensor features

Sensor type SpO2 pulse oximeter clip
Patient population Adult
Cable type Type D
Cable length 0.9 m
Compatibility Monitors K12, K15 (with cable 35318) and Oxy 110
Nature Spare part (spare)
Use Reusable

4. Equivalences and Cross-References

Reference 35317 is the manufacturer’s original code for this adult SpO2 clip sensor with type D cable. Within the same monitoring solution, reference 35318 corresponds to the connection cable required for the K12 and K15 series monitors; the Oxy 110 monitor does not require this additional cable.

No interchangeable 1:1 equivalents of this spare part with sensors from other manufacturers have been found in reliable sources, since compatibility depends on the electrical scheme, the type D connector and the specific configuration of each monitor. If in any doubt, confirm the exact brand and model of your monitor with our technical-commercial department before placing the order.

5. Selection tips and variants of interest

Check the monitor: this spare part is valid for the K12, K15 and Oxy 110 monitors. For the K12 and K15 models, remember to add the connection cable ref. 35318; the Oxy 110 connects directly with the sensor’s integrated cable.

Patient population: this sensor is the adult version. For paediatric or neonatal patients, select the clip sensor or the specific measuring accessory for that population, adapted to the size of the finger or foot.

Maintenance: as a reusable sensor, follow the cleaning and disinfection instructions provided by the manufacturer between patients and avoid sharp bends in the cable to extend its service life.

Stock planning: always keep a spare replacement available to avoid monitor downtime. Consult our technical-commercial team for B2B terms and supply lead times.

Additional information

Manufacturer reference

35317

Sensor type

SpO2 pulse oximeter clip

Cable type

Type D

Cable length

0.9 m

Compatibility

Monitors K12, K15 (with cable 35318) and Oxy 110

Nature

Spare part (spare)

CND code

C900301

GMDN code

36087

EAN

8023279353174

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Tipo paciente

Adult

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Adult Type D SpO2 Clip Sensor – 0.9 m Cable – Replacement for K12, K15 and Oxy 110 Monitors | Ref. 35317”

Your email address will not be published. Required fields are marked *