Description
1. Commercial Introduction
The ZOLL AutoPulse Li-Ion battery (Ref. 8700-0752-01) is the official power pack with which ZOLL equips the mechanical chest compression system AutoPulse (Model 100). Designed for emergency services, ambulances, mobile ICUs and hospital units, this rechargeable lithium-ion (LiFePO₄) battery ensures that the CPR device responds instantly and maintains high-quality compressions during patient treatment and transport. At Cahnos (SKU 88888832) it is available under the original ZOLL reference, verified against regulatory databases, as a professional spare part for your preventive maintenance programme.
2. Technical Explanation
The AutoPulse is a non-invasive cardiac support pump that compresses the whole chest by means of a load-distributing band (LifeBand), generating more consistent blood flow than manual CPR. The platform performs compressions at 80 ± 5 compressions per minute and the lithium-ion battery provides approximately 30 minutes of continuous operation with a nominal patient, enough for most resuscitations and transports. The battery is mechanically keyed for the AutoPulse platform and the SurePower multi-chemistry charger, so it can only be installed correctly in compatible equipment and chargers. It fits into the platform compartment without tools; the system monitors the state of charge by means of a bar indicator (100% = 4 bars) and warns when replacement is needed.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer | ZOLL Circulation, Inc. / ZOLL Medical Corporation |
| Manufacturer reference | 8700-0752-01 (AutoPulse® Li-Ion Battery) |
| Reference Cahnos (SKU) | 88888832 |
| Battery type | Rechargeable lithium-ion (LiFePO₄) |
| Nominal voltage | 36.3 V |
| Capacity | 2,500 mAh |
| Maximum current | 30 A continuous / 48 A pulse (96 ms max.) |
| Initial runtime (nominal patient) | Approx. 30 minutes |
| Maximum charging time | Less than 4 h 15 min at 25 °C (AutoPulse SurePower charger, ref. 8700-0753-01) |
| Dimensions (L × W × H) | 29.2 × 8.1 × 5.7 cm |
| Weight | 1.3 kg |
| Recommended replacement interval | 3 years from the date of manufacture |
| Expected service life | 5 years from date of manufacture |
| Enclosure protection | IP24 according to IEC 60529 |
| Operating temperature | 0 °C to +45 °C (installed in the device) |
| Compatibility | ZOLL AutoPulse (Resuscitation System, Model 100) |
| Regulatory classification | Class II (FDA); UDI-DI GUDID 00849111001823; GMDN “Secondary battery”; non-sterile |
| Presentation | Unit |
Official accessories of the AutoPulse family:
| Component | Official ZOLL reference | Function |
|---|---|---|
| AutoPulse SurePower multi-chemistry charger (2 bays) | 8700-0753-01 | Charging and maintenance of two batteries |
| LifeBand single-use band (pack of 3) | 8700-0706-01 | Single-use, latex-free compression consumable |
| Quick Case transport bag (blue fabric) | 8700-000850-40 | System transport and storage |
4. Equivalences and Cross-References
Reference status: confirmed. Part number 8700-0752-01 appears in the GUDID/FDA registration (Zoll Circulation, Inc., version/model 100, UDI-DI 00849111001823, Class II), in the official ZOLL store (“AutoPulse® Li-Ion Battery”) and consistently across multiple authorised distributors with the same chemistry, voltage (36.3 V) and capacity data. The Cahnos reference 88888832 corresponds to this same original product (exact reference equivalence: same manufacturer, same family, same measurements). The reference shown on other data sheets as “MFR 8700-0752-01” should be read as the distributor’s internal nomenclature for the official ZOLL part number 8700-0752-01.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Stryker / Physio-Control | LUCAS 3 and LUCAS 2 – rechargeable lithium polymer battery | 11576-000080 | Comparable by category (not interchangeable 1:1) | LiPo 25.9 V · 3.3 Ah, approx. 45 min runtime; connector, pack geometry and management electronics specific to the LUCAS system (piston compression); not valid for the AutoPulse platform (load-distributing band) |
There is no manufacturer-validated equivalence table that would allow the AutoPulse battery to be replaced by one from another brand: the connector, compartment and electronic management are proprietary to ZOLL. Other families of mechanical chest compression devices (LUCAS from Stryker, EASY PULSE from Schiller or Corpuls from GS Elektromedizin) share the same clinical indication but differ in mechanism, chemistry, voltage and geometry, and should be treated as a functional category comparison. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Identify your platform: this battery is exclusive to the AutoPulse Model 100 system. Do not install it in X Series defibrillators (SurePower II battery, ref. 8000-0580-01), R/SurePower (8019-0535-01) or AED Pro (8000-0860-01): each ZOLL family uses its own pack.
- Battery rotation: it is recommended to manage 3 or 4 batteries per platform and rotate them every 24 hours, keeping them in the plugged-in multi-chemistry charger when not in active use to ensure immediate availability.
- Preventive maintenance: perform a daily system check with a LifeBand installed and verify the charge is at 100% (4 bars on the indicator). Replace the battery according to the recommended interval of 3 years from the date of manufacture.
- Consumables: the LifeBand is single-use; replace it with the pack of 3 (ref. 8700-0706-01) after each patient and complete the transport with the Quick Case bag (ref. 8700-000850-40).
- Expansions: if you already have an AutoPulse platform, you can expand the system with additional batteries (8700-0752-01) and the 2-bay charger (8700-0753-01). Consult the technical department about the AutoPulse NXT configuration for patients with a larger chest circumference.
- Recycling: dispose of the depleted battery at WEEE collection points in accordance with current regulations (regulated lithium transport).